{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PEM115B","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PEM115B","canonicalUrl":"https://aoctrl.com/schneider/GV4PEM115B","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PEM115B","rawCanonicalId":null},"summary":{"shortDescription":"TeSys GV4, motor circuit breaker, 115 A, 3-pole, 50 kA at 240 V, EverLink terminals, Gray RAL 7016).","salesMarkdown":"The TeSys GV4PEM115B is a 3-pole motor circuit breaker from the TeSys Deca range, rated 115 A continuous. It's built for motor protection and isolation in industrial panels, compliant with IEC 60947-2 and 60947-4-1 and UL 60947-4-1. Rated motor power spans 37 kW to 110 kW depending on voltage: 37 kW at 400 V, 45 kW at 400 V, 55 kW at 400 V, 45/55/75 kW at 500 V, and 75/90/110 kW at 660-690 V AC. That covers a wide range of standard induction motors in conveying, pumping, and fan applications. Breaking capacity is 50 kA Icu at 220-240 V AC under IEC 60947-2, 25 kA at 380-415 V, 20 kA at 440 V, and 10 kA at 500 V. For UL ratings, it delivers 35 kA at 240 V, 18 kA at 480Y/277 V, and 14 kA at 600Y/347 V. That gives you headroom for high-fault panels without needing a separate current-limiting fuse. Trip unit is thermal-magnetic with an electronic component—magnetic trip set at 1955 A (17x In). Phase failure sensitivity is built in per IEC 60947-4-1, so the breaker will trip on a lost phase, protecting the motor from single-phasing. Power dissipation is 4.6 W per pole, which matters for panel heat budgeting in tightly packed enclosures. Mechanical durability is rated at 40,000 cycles, electrical durability at 10,000 cycles under AC-3 at 440 V at In/2, and 5,000 cycles at full In. Maximum operating rate is 25 cycles per hour—typical for a motor start/stop duty but not for frequent switching. Environmental protection: IP40 enclosure, IK07 impact resistance, pollution degree 3. That means the breaker can live in a general industrial panel (no washdown) and withstand typical mechanical knocks. Terminals are EverLink BTR screw type accepting up to 95 mm² solid on the bottom and 70 mm² flexible—enough for motor feeds up to the full 115 A. The GV4PEM115B complies with UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2. Fire resistance is verified to 960 °C (glow wire test IEC 60695-2-11). Climatic withstand is IACS, meaning it's suitable for tropical and temperate climates. The product is part of the current TeSys Deca range. ## Installation and wiring details Depth is 4.6 in (116 mm), width 3.2 in (81 mm), height 6.1 in (155 mm). Tightening torque for main terminals: 79.7 lbf.in (9 N.m) for 16-95 mm², and 44.3 lbf.in (5 N.m) for 1.5-10 mm². The operating position is any, so you can lay it sideways if panel depth is tight. Din-rail mounting is standard for the TeSys Deca series.","metaTitle":"TeSys GV4PEM115B Motor Circuit Breaker, 115A, 50kA","metaDescription":"115 A 3-pole motor circuit breaker with thermal-magnetic electronic trip, 50 kA breaking capacity at 240 V, 37-110 kW at 400-690 V. UL/CSA/IEC listed, EverLink terminals, Gray RAL","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Range":"TeSys Deca","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Category":"US10I1122365","Standards":"CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous IEC 60947-4-1","Control Type":"Toggle","Product name":"TeSys GV4","Motor power kW":"37 kW 400...415 V AC 50/60 Hz 45 kW 400...415 V AC 50/60 Hz 55 kW 400...415 V AC 50/60 Hz 45 kW 500 V AC 50/60 Hz 55 kW 500 V AC 50/60 Hz 75 kW 500 V AC 50/60 Hz 75 kW 660...690 V AC 50/60 Hz 90 kW 660...690 V AC 50/60 Hz 110 kW 660...690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Pollution degree":"3","Range of Product":"TeSys GV4","Breaking capacity":"50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 35 kA 208Y/120 V AC 50/60 Hz UL 60947 35 kA 240 V AC 50/60 Hz UL 60947 18 kA 480Y/277 V AC 50/60 Hz UL 60947 14 kA 600Y/347 V AC 50/60 Hz UL 60947","Device short name":"GV4PEM","Poles description":"3P","Tightening torque":"79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"115 A","Operating altitude":"5000 m","Operating position":"Any position","Trip unit technology":"Thermal-magnetic Electronic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"10000 cycles AC-3 440 V In/2 5000 cycles AC-3 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"EverLink BTR screw connectors top) 1 0.002...0.1 in² (1.5...70 mm²) - solid EverLink BTR screw connectors top) 1 0.002...0.08 in² (1.5...50 mm²) - flexible EverLink BTR screw connectors bottom) 1 0.004...0.1 in² (2.5...95 mm²) - solid EverLink BTR screw connectors bottom) 1 0.004...0.1 in² (2.5...70 mm²) - flexible","IK degree of protection":"IK07 IEC 62262","IP degree of protection":"IP40 IEC 60529","Magnetic tripping current":"1955 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"4.6 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2","[Ith] conventional free air thermal current":"115 A IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cc88fe9e394965dc167bdd644d7f3983.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PEM115B/alternatives.json"},"ai":{"faq":[{"question":"What is the color of the GV4PEM115B?","answer":"The housing color is Gray RAL 7016)."},{"question":"What are the overall dimensions of the GV4PEM115B?","answer":"It measures 6.1 in (155 mm) high, 3.2 in (81 mm) wide, and 4.6 in (116 mm) deep."},{"question":"What compliance standards does the GV4PEM115B meet?","answer":"It is certified to UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2. It also passes glow wire test at 960 °C."},{"question":"What is the rated motor power range for this breaker?","answer":"Depending on voltage and configuration, it covers 37 kW to 110 kW at 400-690 V AC."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PEM115B","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PEM115B when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}