{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PEM115B6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PEM115B6","canonicalUrl":"https://aoctrl.com/schneider/GV4PEM115B6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PEM115B6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 motor circuit breaker, GV4PEM115B6, 3-pole, 115 A line rated, thermal-magnetic and electronic trip, 50 kA breaking capacity at 240 V AC, IP40, gray RAL 7016.","salesMarkdown":"## 115 A motor circuit breaker for TeSys Deca panels The GV4PEM115B6: It combines thermal-magnetic and electronic trip technology to protect motors against overload, short-circuit, and phase failure — the electronic element provides adjustable protection curves that a purely thermal device cannot. At 415 V the rating drops to 25 kA, still adequate for typical motor branch circuits. ## Motor power coverage and trip coordination This breaker covers motors from 37 kW up to 110 kW depending on supply voltage — for example, 37 kW at 400 V, 55 kW at 500 V, and 110 kW at 690 V. The wide power range means a single frame size handles multiple motor ratings, simplifying panel stock. Magnetic trip threshold is fixed at 1955 A, which is 17× the line rating — this prevents nuisance tripping on motor inrush while still clearing a bolted fault quickly. Phase failure sensitivity per IEC 60947-4-1 ensures the breaker opens if one phase drops out, avoiding single-phase motor burnup. Mechanical durability is 40,000 cycles. Dimensions are 6.1 in (155 mm) high, 3.2 in (81 mm) wide, and 4.6 in (116 mm) deep — fits standard 35 mm DIN rail. Connection pitch is 27 mm without spreaders, expanding to 35 mm with spreaders for larger cable lugs up to 95 mm². IP40 front protection and IK07 impact resistance suit indoor panel environments. Pollution degree 3 means it tolerates conductive dust and occasional condensation — typical for factory-floor enclosures without climate control. The fire resistance rating of 960 °C per IEC 60695-2-11 supports global panel certification requirements.","metaTitle":"Schneider Electric GV4PEM115B6 TeSys GV4 MPCB, 115 A, 3-Pole","metaDescription":"Schneider Electric GV4PEM115B6 TeSys GV4 motor circuit breaker, 115 A line rated, 3-pole, thermal-magnetic & electronic trip. UL/CSA/IEC. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Voltage":"690 V AC 50/60 Hz IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders","Trip Unit Type":"Thermal-magnetic Electronic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 35 kA 208Y/120 V AC 50/60 Hz UL 60947 35 kA 240 V AC 50/60 Hz UL 60947 18 kA 480Y/277 V AC 50/60 Hz UL 60947 14 kA 600Y/347 V AC 50/60 Hz UL 60947","Insulation Voltage Ui":"800 V AC 50/60 Hz IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-58...185 °F (-50...85 °C)","Utilization Category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical Life Cycles":"10000 cycles AC-3 440 V In/2 5000 cycles AC-3 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-13...158 °F (-25...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/GV4PEM115B6/motor-circuit-breaker-tesys-gv4-3p-115a-icu-25ka-thermal-magnetic-multifunction-lugs-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PEM115B6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PEM115B6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PEM115B6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}