{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PEM115S6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PEM115S6","canonicalUrl":"https://aoctrl.com/schneider/GV4PEM115S6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PEM115S6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 motor circuit breaker, GV4PEM115S6, 115 A rated current, 3-pole, thermal-magnetic with electronic trip, 120 kA breaking capacity at 240 V AC, IP40, gray RAL 7016.","salesMarkdown":"## 115 A rated current — motor protection threshold and load coverage The GV4PEM115S6 is a 3-pole motor circuit breaker from the TeSys GV4 range, rated at 115 A line current. That rating sets the full-load current ceiling for the motor it protects — the breaker's thermal-magnetic and electronic trip unit responds to sustained overloads and short-circuit events up to that threshold. Motor power coverage spans 37 kW at 400 V up to 110 kW at 690 V, so the same breaker frame serves a wide band of motor sizes depending on the supply voltage. The magnetic trip is fixed at 1955 A, which is about 17× In — typical for a motor-starting inrush without nuisance trips on start. ## 120 kA breaking capacity — SCCR headroom for high-fault panels At 480Y/277 V the rating is 65 kA — still well above the typical 10–18 kA available fault current in most industrial panels. This gives the panel designer headroom for high-SCCR buswork without cascading upstream fuses. ## Active production — no lifecycle risk for BOM freeze For a contract manufacturer managing multiple customer AVLs, this part sits on Schneider's standard catalogue and is widely accepted across industrial OEM specs. No deviation or change request is needed for new builds that specify TeSys GV4 motor protection. ## Panel fit and connection pitch Dimensions are 6.1 in (155 mm) high, 3.2 in (81 mm) wide, 4.6 in (116 mm) deep. The connection pitch is 27 mm without spreaders, expanding to 35 mm with spreaders — this affects busbar spacing and cable lug alignment in the panel. Terminals accept lugs or ring terminals for 16–95 mm² cable on the line side and 1.5–10 mm² on the control side. IP40 enclosure means it is suitable for indoor panel use where no washdown or dust ingress is expected.","metaTitle":"Schneider Electric GV4PEM115S6 TeSys GV4 MPCB, 115 A, 120 kA","metaDescription":"Schneider Electric GV4PEM115S6 TeSys GV4 motor circuit breaker, 115 A rated current, 120 kA breaking capacity at 240 V. UL/CSA/IEC listed. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Range":"TeSys Deca","Width":"3.2 in (81 mm)","title":"GV4PEM115S6","Height":"6.1 in (155 mm)","Category":"US10I1122365","Standards":"CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous IEC 60947-4-1","description":"Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic multifunction, lugs terminals","Control Type":"Toggle","Product name":"TeSys GV4","Motor power kW":"37 kW 400...415 V AC 50/60 Hz 45 kW 400...415 V AC 50/60 Hz 55 kW 400...415 V AC 50/60 Hz 45 kW 500 V AC 50/60 Hz 55 kW 500 V AC 50/60 Hz 75 kW 500 V AC 50/60 Hz 75 kW 660...690 V AC 50/60 Hz 90 kW 660...690 V AC 50/60 Hz 110 kW 660...690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Connection pitch":"1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders","Pollution degree":"3","Range of Product":"TeSys GV4","Breaking capacity":"120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 100 kA 208Y/120 V AC 50/60 Hz UL 60947 100 kA 240 V AC 50/60 Hz UL 60947 65 kA 480Y/277 V AC 50/60 Hz UL 60947 10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA 600Y/347 V AC 50/60 Hz UL 60947","Device short name":"GV4PEM","Poles description":"3P","Tightening torque":"79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"115 A","Operating altitude":"5000 m","Operating position":"Any position","Trip unit technology":"Thermal-magnetic Electronic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"10000 cycles AC-3 440 V In/2 5000 cycles AC-3 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"Lugs-ring terminals","IK degree of protection":"IK07 IEC 62262","IP degree of protection":"IP40 IEC 60529","Magnetic tripping current":"1955 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"4.6 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2","[Ith] conventional free air thermal current":"115 A IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/us/en/product/GV4PEM115S6/motor-circuit-breaker-tesys-gv4-3p-115a-icu-100ka-thermal-magnetic-multifunction-lugs-terminals/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PEM115S6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PEM115S6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}