{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PEM50B6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PEM50B6","canonicalUrl":"https://aoctrl.com/schneider/GV4PEM50B6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PEM50B6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV4PEM50B6 motor circuit breaker, 3-pole, 50 A rated current, thermal-magnetic and electronic trip, 50 kA breaking capacity at 240 V AC, IP40, gray RAL 7016.","salesMarkdown":"## 50 A motor circuit breaker with 50 kA interrupting capacity The GV4PEM50B6: Rated for AC-3 utilisation category per IEC 60947-4-1, this MPCB is designed specifically for switching motor loads — not just resistive heating. ## Dual trip technology and phase loss protection The trip unit combines thermal-magnetic and electronic elements — the thermal bimetal handles overloads with an inverse-time curve, while the magnetic coil (850 A fixed) clears short-circuits. The electronic circuit adds phase-failure sensitivity per IEC 60947-4-1, so a lost phase on the line side trips the breaker before single-phasing damages the motor. Power dissipation is 4.6 W per pole at rated current — budget this into the panel thermal calculation when grouping multiple MPCBs in a closed enclosure. The 40,000-cycle mechanical endurance and 20,000-cycle electrical endurance at AC-3 rated current give a realistic service life for production machinery running 25 cycles per hour maximum operating rate. ## Panel fit and compliance documentation The GV4PEM50B6 mounts on standard DIN rail with a 27 mm connection pitch between poles — this matches the TeSys Deca busbar system without spreaders. With spreaders fitted, the pitch opens to 35 mm to accommodate larger cable lugs up to 95 mm². The IP40 front face and IK07 impact resistance are adequate for enclosed panel mounting; this is not a washdown-rated device.","metaTitle":"Schneider GV4PEM50B6 TeSys Deca MPCB, 50 A, 50 kA","metaDescription":"Schneider Electric GV4PEM50B6 TeSys Deca motor circuit breaker, 50 A rated current, 50 kA breaking capacity at 240 V. UL/CSA/IEC listed.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Voltage":"690 V AC 50/60 Hz IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders","Trip Unit Type":"Thermal-magnetic Electronic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 35 kA 208Y/120 V AC 50/60 Hz UL 60947 35 kA 240 V AC 50/60 Hz UL 60947 18 kA 480Y/277 V AC 50/60 Hz UL 60947 14 kA 600Y/347 V AC 50/60 Hz UL 60947","Insulation Voltage Ui":"800 V AC 50/60 Hz IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-58...185 °F (-50...85 °C)","Utilization Category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical Life Cycles":"20000 cycles AC-3 440 V In/2 10000 cycles AC-3 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-13...158 °F (-25...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/GV4PEM50B6/motor-circuit-breaker-tesys-gv4-3p-50a-icu-25ka-thermal-magnetic-multifunction-lugs-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PEM50B6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PEM50B6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PEM50B6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}