{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PEM50S6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PEM50S6","canonicalUrl":"https://aoctrl.com/schneider/GV4PEM50S6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PEM50S6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 GV4PEM50S6 motor circuit breaker, 3-pole, 50 A line rated current, electronic thermal-magnetic trip, 120 kA breaking capacity at 240 V, IP40, gray RAL 7016.","salesMarkdown":"## 50 A motor circuit breaker with global short-circuit ratings The GV4PEM50S6: It sits in the TeSys Deca range and is designed for motor protection in industrial control panels. These numbers mean it clears high-fault currents without upstream coordination headaches in most industrial distribution systems. The magnetic trip threshold is set at 850 A — roughly 17× In — which keeps the breaker from nuisance-tripping on motor inrush while still catching bolted faults early. Motor power coverage spans 11 kW at 400 V up to 45 kW at 690 V, making this one breaker cover a wide motor range depending on your line voltage. The AC-3 utilisation category confirms it is rated for switching squirrel-cage motors — the standard duty for a motor circuit breaker. Phase failure sensitivity per IEC 60947-4-1 protects the motor from single-phasing damage when one supply line drops. The electronic trip detects the imbalance and opens before the motor overheats. Suitability for isolation per IEC 60947-1 means this breaker can serve as a visible-break disconnect for safe maintenance — no separate isolator needed upstream. Power dissipation is 4.6 W per pole, totalling 13.8 W at full load. Budget this into enclosure thermal calculations to avoid derating when multiple breakers are ganged in a small panel. ## Panel fit and termination details Dimensions are 3.2 in wide × 6.1 in high × 4.6 in deep (81 × 155 × 116 mm). The connection pitch is 27 mm without spreaders and 35 mm with spreaders — important when laying out busbars or lug kits across multiple breakers on a DIN rail. Terminals accept lugs or ring terminals: 1.5-10 mm² at 5 N·m torque, and 16-95 mm² at 9 N·m. The larger lug range handles the full 50 A load with standard power conductors. IP40 protection means it is suited for dry indoor panels only — not for washdown or outdoor enclosures without additional cabinet protection. IK07 impact resistance handles incidental tool bumps during installation. ## Lifecycle and compliance — active, not legacy This covers North American and European installations without additional certification paperwork. Fire resistance tested to 960 °C per IEC 60695-2-11, pollution degree 3, and operating altitude to 5000 m — all standard industrial environment ratings that match typical factory floor conditions.","metaTitle":"Schneider GV4PEM50S6 TeSys GV4 Motor Circuit Breaker, 50 A","metaDescription":"Schneider Electric GV4PEM50S6 TeSys GV4 motor circuit breaker, 50 A rated current, 3-pole, electronic thermal-magnetic trip. UL/CSA/IEC listed.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Voltage":"690 V AC 50/60 Hz IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders","Trip Unit Type":"Electronic Thermal-magnetic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 100 kA 208Y/120 V AC 50/60 Hz UL 60947 100 kA 240 V AC 50/60 Hz UL 60947 65 kA 480Y/277 V AC 50/60 Hz UL 60947 10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA 600Y/347 V AC 50/60 Hz UL 60947","Insulation Voltage Ui":"800 V AC 50/60 Hz IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-58...185 °F (-50...85 °C)","Utilization Category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical Life Cycles":"20000 cycles AC-3 440 V In/2 10000 cycles AC-3 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-13...158 °F (-25...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/au/en/product/GV4PEM50S6/motor-circuit-breaker-tesys-gv4-tesys-gv4-3p-50a-icu-100ka-thermal-magnetic-multifunction-lugs-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PEM50S6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PEM50S6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PEM50S6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}