{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PEM80B6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PEM80B6","canonicalUrl":"https://aoctrl.com/schneider/GV4PEM80B6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PEM80B6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 motor circuit breaker, GV4PEM80B6, 80 A, 3-pole, thermal-magnetic and electronic trip, 50 kA breaking capacity at 240 V AC, IP40, gray RAL 7016.","salesMarkdown":"## Motor circuit breaker for 37 kW at 400 V The GV4PEM80B6 is a 3-pole motor circuit breaker from the TeSys GV4 range, rated 80 A continuous and designed for motor protection per IEC 60947-4-1 and UL 60947-4-1. ## Breaking capacity and trip technology The trip unit combines thermal-magnetic and electronic elements: the magnetic trip is fixed at 1360 A (17× In), and phase-failure sensitivity is built in per IEC 60947-4-1, so it catches single-phasing before the motor overheats. ## Panel fit and environmental specs Dimensions are 6.1 in (155 mm) high by 3.2 in (81 mm) wide by 4.6 in (116 mm) deep, with a connection pitch of 1.06 in (27 mm) without spreaders or 1.4 in (35 mm) with spreaders — the spreaders give extra clearance for larger cable lugs. Rated IP40 (finger-safe) and IK07 (impact resistance), with pollution degree 3, so it suits industrial control panels where dust and light contaminants are present. ## Durability and operating cycle Mechanical durability is 40,000 cycles; electrical durability under AC-3 at 440 V is 14,000 cycles at 1× In and 7,000 cycles at full rated current. Maximum operating rate is 25 cycles per hour — this breaker is built for occasional switching, not continuous jogging. The continuous duty rating (IEC 60947-4-1) means it can hold rated current indefinitely without derating. Carries CSA C22.2 No 60947-4-1, UL 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2 approvals — accepted across North America and Europe without additional certification. Fire resistance tested to 960 °C (IEC 60695-2-11). Suitability for isolation per IEC 60947-1 means it can serve as a visible disconnect in the motor branch circuit.","metaTitle":"Schneider GV4PEM80B6 Motor Circuit Breaker, 80 A, 50 kA","metaDescription":"Schneider Electric GV4PEM80B6 TeSys GV4 motor circuit breaker, 80 A rated current, 50 kA breaking capacity at 240 V. Active production. UL/CSA/IEC.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Range":"TeSys Deca","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Category":"US10I1122365","Standards":"CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous IEC 60947-4-1","Control Type":"Toggle","Product name":"TeSys GV4","Motor power kW":"37 kW 400...415 V AC 50/60 Hz 45 kW 500 V AC 50/60 Hz 22 kW 400...415 V AC 50/60 Hz 30 kW 500 V AC 50/60 Hz 37 kW 660...690 V AC 50/60 Hz 45 kW 660...690 V AC 50/60 Hz 55 kW 660...690 V AC 50/60 Hz 30 kW 400...415 V AC 50/60 Hz 37 kW 500 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Connection pitch":"1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders","Pollution degree":"3","Range of Product":"TeSys GV4","Breaking capacity":"50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 35 kA 208Y/120 V AC 50/60 Hz UL 60947 35 kA 240 V AC 50/60 Hz UL 60947 18 kA 480Y/277 V AC 50/60 Hz UL 60947 14 kA 600Y/347 V AC 50/60 Hz UL 60947","Device short name":"GV4PEM","Poles description":"3P","Tightening torque":"79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"80 A","Operating altitude":"5000 m","Operating position":"Any position","Trip unit technology":"Thermal-magnetic Electronic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"14000 cycles AC-3 440 V In/2 7000 cycles AC-3 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"Lugs-ring terminals","IK degree of protection":"IK07 IEC 62262","IP degree of protection":"IP40 IEC 60529","Magnetic tripping current":"1360 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"4.6 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2","[Ith] conventional free air thermal current":"115 A IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/us/en/product/GV4PEM80B6/motor-circuit-breaker-tesys-gv4-3p-80a-icu-25ka-thermal-magnetic-multifunction-lugs-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PEM80B6/alternatives.json"},"ai":{"faq":[{"question":"How can I get pricing and availability for GV4PEM80B6?","answer":"Submit an RFQ for current pricing and confirmed lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PEM80B6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PEM80B6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}