{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PEM80N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PEM80N","canonicalUrl":"https://aoctrl.com/schneider/GV4PEM80N","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PEM80N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 series, GV4PEM80N motor circuit breaker, 80 A, 3-pole, thermal-magnetic and electronic trip, 100 kA breaking capacity at 240 V AC, IP40, gray RAL 7016.","salesMarkdown":"## 80 A motor circuit breaker for TeSys Deca panels The GV4PEM80N is a 3-pole motor circuit breaker from the TeSys GV4 range, rated 80 A continuous line current and designed for motor protection under IEC 60947-4-1 and UL 60947-4-1. It sits in the TeSys Deca family, which means it shares the same panel footprint and busbar system as the larger Deca contactors — a single cutout for the whole motor starter stack. ## Trip unit and protection logic Dual trip technology: thermal-magnetic for overload and short-circuit, plus an electronic module for additional protection curves. The magnetic trip is fixed at 1360 A (17× In), which coordinates well with downstream contactors rated for AC-3 switching duty. Phase-failure sensitivity per IEC 60947-4-1 is built in — no separate phase-loss relay needed. The thermal-magnetic element handles the overload region; the electronic module adds adjustable trip classes if the application requires tighter coordination. Pollution degree 3 rating means it tolerates conductive dust in unsealed enclosures — common in panel environments without filtered air. ## Breaking capacity and selectivity headroom At 400 V, the Icu is 50 kA (IEC 60947-2) and the UL rating at 480Y/277 V is 35 kA. This is a Category A breaker — it is not intended for reverse-feed or bidirectional current interruption, but for downstream motor protection where the fault current is well-characterized. For 690 V systems, the breaking capacity drops to 8 kA Icu — if the available fault current at 690 V exceeds that, an upstream fuse or breaker with higher interrupting rating is required. The 500 V rating of 25 kA Icu covers most European 500 V industrial networks. Dimensions: 81 mm wide, 155 mm high, 116 mm deep — fits standard DIN-rail or screw-fixed mounting in a TeSys Deca backplate. The EverLink BTR screw terminals accept solid copper up to 95 mm² on the bottom (load side) and 70 mm² on the top (line side), with flexible cable up to 70 mm². Tightening torque is 9 N·m for the main power terminals, 5 N·m for the control loop connections. The gray RAL 7016 housing is standard for the TeSys Deca line, matching the contactor and overload relay in the same family. The GV4 series is the successor to the earlier GV2 and GV3 motor circuit breakers, offering higher breaking capacities and the EverLink terminal system. No direct cross-reference to a different manufacturer's part — the TeSys Deca platform is Schneider-specific in its mounting and busbar interface.","metaTitle":"Schneider Electric GV4PEM80N TeSys GV4 Motor Circuit Breaker","metaDescription":"Schneider Electric GV4PEM80N TeSys GV4 motor circuit breaker, 80 A rated current, 100 kA breaking capacity at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Voltage":"690 V AC 50/60 Hz IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Trip Unit Type":"Thermal-magnetic Electronic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-58...185 °F (-50...85 °C)","Utilization Category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical Life Cycles":"14000 cycles AC-3 440 V In/2 7000 cycles AC-3 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-13...158 °F (-25...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$982.14 – $1,225.57","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/GV4PEM80N/motor-circuit-breaker-tesys-gv4-3p-80a-icu-50ka-thermal-magnetic-multifunction-everlink-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PEM80N/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PEM80N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PEM80N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}