{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PEM80S","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PEM80S","canonicalUrl":"https://aoctrl.com/schneider/GV4PEM80S","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PEM80S","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 motor circuit breaker, GV4PEM80S, 80 A, 3-pole, thermal-magnetic with electronic trip, 120 kA breaking capacity at 240 V AC, IP40, gray RAL 7016.","salesMarkdown":"## 80 A motor circuit breaker for 37 kW at 400 V The GV4PEM80S: It combines motor protection and isolation in one DIN-rail-mounted device, replacing a separate breaker and contactor in many panel layouts. At 480Y/277 V UL rating drops to 65 kA, still covering most industrial service entrances. ## Trip unit and motor protection logic Dual-technology trip: thermal-magnetic for overload and short-circuit, plus an electronic module for phase-failure sensitivity per IEC 60947-4-1. Magnetic trip threshold is fixed at 1360 A — 17× In — meaning it clears bolted faults fast but won't nuisance-trip on motor inrush. Rated for continuous duty (IEC 60947-4-1) and utilisation category AC-3, so it's built for starting and stopping squirrel-cage motors under load. Electrical durability is 14,000 cycles at AC-3 440 V at In/2, and 7,000 cycles at full In — plan spares for high-cycle applications. Mechanical life is 40,000 cycles, with a max operating rate of 25 cycles/hour. The toggle control gives positive manual on/off and trip indication — no auxiliary power needed for the isolation function. Footprint is 81 mm wide × 155 mm high × 116 mm deep — fits a standard 3-module DIN-rail slot. IP40 enclosure with IK07 impact resistance; fine for inside a panel but not for washdown zones. EverLink BTR screw terminals on top accept 1.5...70 mm² solid or 1.5...50 mm² flexible; bottom terminals take 2.5...95 mm² solid or 2.5...70 mm² flexible. Tightening torque is 9 N·m for the main power terminals, 5 N·m for the control wiring — use a torque screwdriver; the EverLink clamp is sensitive to over-torque. Power dissipation is 4.6 W per pole — 13.8 W total at rated current. Factor this into the panel thermal budget; in a sealed enclosure with multiple breakers, the heat adds up. Suitable for isolation per IEC 60947-1 — no need for a separate disconnect. Sourced to order against BOM quantities through independent distribution.","metaTitle":"Schneider Electric GV4PEM80S TeSys GV4 Motor Circuit Breaker","metaDescription":"Schneider Electric GV4PEM80S TeSys GV4 motor circuit breaker, 80 A rated current, 120 kA breaking capacity at 240 V. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Voltage":"690 V AC 50/60 Hz IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Trip Unit Type":"Thermal-magnetic Electronic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 100 kA 208Y/120 V AC 50/60 Hz UL 60947 100 kA 240 V AC 50/60 Hz UL 60947 65 kA 480Y/277 V AC 50/60 Hz UL 60947 10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA 600Y/347 V AC 50/60 Hz UL 60947","Insulation Voltage Ui":"800 V AC 50/60 Hz IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-58...185 °F (-50...85 °C)","Utilization Category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical Life Cycles":"14000 cycles AC-3 440 V In/2 7000 cycles AC-3 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-13...158 °F (-25...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,072.45 – $1,420.11","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/GV4PEM80S/motor-circuit-breaker-tesys-gv4-3p-80a-icu-100ka-thermal-magnetic-multifunction-everlink-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PEM80S/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PEM80S","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PEM80S when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}