{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV7AS525","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV7AS525","canonicalUrl":"https://aoctrl.com/schneider/GV7AS525","factsUrl":"https://aoctrl.com/api/mcp/products/GV7AS525","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV7AS525, MX shunt trip voltage release, 525 V AC 50 Hz, for GV5/GV6/GV7 manual motor protectors.","salesMarkdown":"The GV7AS525 is a TeSys MX shunt trip — a voltage release that trips a GV5, GV6, or GV7 manual motor protector when control voltage is applied to its coil. It is the remote-trip accessory, not the main breaker. Rated for 525 V AC 50 Hz control circuits, it operates in under 50 ms per IEC 60947-1, which means it opens the protector fast enough to clear a fault before downstream damage escalates. That covers standard 400/480 VAC panels with headroom. The control circuit accepts 0.7...1.1 Un, so a 525 V nominal coil holds in down to about 367 V and up to 577 V — useful if your control transformer sags under load. The threshold tripping voltage is 0.2...0.75 Ue, meaning the release drops out and trips the protector when the control voltage falls between roughly 105 V and 394 V (on a 525 V system). That wide dropout band makes it forgiving of brownout conditions, but verify your undervoltage protection coordination: if you need a tighter dropout, this is not the part. Screw-clamp terminals accept 1 mm² solid, 1.5 mm² flexible without ferrule, or 1.5 mm² flexible with ferrule. Tightening torque is 1.2 N.m — a standard small screwdriver setting. The shunt trip mounts directly onto the left side of the GV5, GV6, or GV7 protector body; it does not occupy additional DIN rail space beyond the protector footprint. Inrush power is 10 VA AC, hold-in is 5 VA AC, so the control transformer must be sized for the inrush peak if multiple releases fire simultaneously.","metaTitle":"Schneider GV7AS525 TeSys Shunt Trip, 525 V AC 50 Hz","metaDescription":"GV7AS525 is an active TeSys MX shunt trip voltage release for GV5/GV6/GV7. 525 V AC 50 Hz control circuit, 690 V AC rated insulation. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"TeSys","title":"GV7AS525","Category":"22366-MAN STR PROTECTORS-GV1/GV3","description":"Voltage release, TeSys GV5 GV6 GV7, MX shunt trip, 525V AC 50Hz","On-load factor":"100 %","Operating time":"< 50 ms IEC 60947-1","lifecycle_stage":"current","Quantity per Set":"Set of 10","Device short name":"GV7AS","Tightening torque":"1.2 N.m screw clamp terminals","Device Application":"Control","Inrush power in VA":"10 VA AC","Nbr. of units in pkg.":"1","Connections - terminals":"screw clamp terminals 1 0.002 in² (1 mm²)flexible with cable end screw clamp terminals 1 0.002 in² (1.5 mm²)flexible without cable end screw clamp terminals 1 0.002 in² (1.5 mm²)solid","Product or Component Type":"Shunt trip","Threshold tripping voltage":"0.2...0.75 Ue","[Uc] control circuit voltage":"525 V AC 50 Hz","[Ui] rated insulation voltage":"690 V AC IEC 60947-1 600 V AC UL 508 600 V AC CSA C22.2 No 14","Control circuit voltage limits":"0.7...1.1 Un","Hold-in Power Consumption in VA":"5 VA AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3c092dabf4e43670b018f7f29def00e.pdf","sourceUrl":"https://www.se.com/be/en/product/GV7AS525/voltage-release-tesys-gv5-gv6-gv7-mx-shunt-trip-525v-ac-50hz/"},"ai":{"faq":[{"question":"What is the TeSys range and category for this part?","answer":"It belongs to the TeSys range, category 22366-MAN STR PROTECTORS-GV1/GV3, which covers manual motor protectors and their accessories."},{"question":"What compliance documentation is available for GV7AS525?","answer":"The part carries IEC 60947-1, UL 508, and CSA C22.2 No 14 approvals as stated for the rated insulation voltage. RoHS and REACH compliance are standard for Schneider TeSys products, but specific declarations should be confirmed at order placement."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV7AS525","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV7AS525 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}