{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV7AU525","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV7AU525","canonicalUrl":"https://aoctrl.com/schneider/GV7AU525","factsUrl":"https://aoctrl.com/api/mcp/products/GV7AU525","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV7AU525 undervoltage trip, 525 VAC 50 Hz, for GV5/GV6/GV7 manual motor protectors.","salesMarkdown":"The GV7AU525 is an undervoltage trip (MN release) from the TeSys range, designed to drop out the GV5, GV6, or GV7 manual motor protector when the control voltage falls below a set threshold. That's another SKU I don't need to second-guess — it's a standard undervoltage coil, not a special. It operates on a 525 V AC 50 Hz control circuit, with a trip threshold of 0.35 to 0.7 Ue. The rated insulation voltage is 690 V AC per IEC 60947-1, with UL 508 and CSA C22.2 No 14 approvals at 600 V AC. That covers most North American and European panel builds without a separate isolation transformer. ## Integration notes Screw-clamp terminals accept 1 mm² to 1.5 mm² conductors — solid, flexible with ferrule, or flexible without. Tighten to 1.2 N·m. The inrush draw is 10 VA, holding at 5 VA, so the control transformer sizing is straightforward. Operating time under 50 ms per IEC 60947-1 means it clears fast enough for most coordinated protection schemes.","metaTitle":"TeSys GV7AU525 Undervoltage Trip, 525 VAC 50 Hz","metaDescription":"GV7AU525 undervoltage trip for TeSys GV5/GV6/GV7 manual starters. 525 VAC 50 Hz control voltage, 0.35-0.7 Ue trip threshold. Active production. Order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"TeSys","title":"GV7AU525","Category":"22366-MAN STR PROTECTORS-GV1/GV3","description":"Voltage release, TeSys GV5 GV6 GV7, MN undervoltage trip, 525V AC 50Hz","On-load factor":"100 %","Operating time":"< 50 ms IEC 60947-1","lifecycle_stage":"current","Quantity per Set":"Set of 10","Device short name":"GV7AS","Tightening torque":"1.2 N.m screw clamp terminals","Device Application":"Control","Inrush power in VA":"10 VA AC","Nbr. of units in pkg.":"1","Connections - terminals":"screw clamp terminals 1 0.002 in² (1 mm²)flexible with cable end screw clamp terminals 1 0.002 in² (1.5 mm²)flexible without cable end screw clamp terminals 1 0.002 in² (1.5 mm²)solid","Product or Component Type":"Undervoltage trip","Threshold tripping voltage":"0.35...0.7 Ue","[Uc] control circuit voltage":"525 V AC 50 Hz","[Ui] rated insulation voltage":"690 V AC IEC 60947-1 600 V AC UL 508 600 V AC CSA C22.2 No 14","Control circuit voltage limits":"0.85...1.1 Un","Hold-in Power Consumption in VA":"5 VA AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fed9a303d339d5a41d1b7c9e348a6292.pdf","sourceUrl":"https://www.se.com/us/en/product/GV7AU525/voltage-release-tesys-gv5-gv6-gv7-mn-undervoltage-trip-525v-ac-50hz/"},"ai":{"faq":[{"question":"What approvals does the GV7AU525 carry?","answer":"It is rated for insulation at 690 V AC per IEC 60947-1, and 600 V AC per UL 508 and CSA C22.2 No 14. These are the standard approvals for panel builders in North American and IEC markets."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV7AU525","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV7AU525 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}