{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GVAED1013","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GVAED1013","canonicalUrl":"https://aoctrl.com/schneider/GVAED1013","factsUrl":"https://aoctrl.com/api/mcp/products/GVAED1013","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GVAED1013 auxiliary contact block, 2 NO (1 NO fault signal), 2.5 A switching current, front-mount, spring terminal, for GV2/GV3 (except GV3ME).","salesMarkdown":"## Overview The GVAED1013 is a front-mount auxiliary contact block in the TeSys Deca range, providing 2 NO contacts — one dedicated as a fault signal — for GV2 and GV3 manual motor starters (excluding GV3ME). Rated at 2.5 A switching current with spring-clamp terminals, it carries CB, CE, UKCA, CCC, cULus, and EAC certifications and is in active production. ## Selection vs GVAED0113 The GVAED0113 carries 1 NO + 1 NC contacts; the GVAED1013 uses 2 NO. Pick the GVAED1013 when the BOM calls for two normally-open auxiliary paths — the GVAED0113 when a normally-closed signal is required.","metaTitle":"Schneider GVAED1013 TeSys Deca auxiliary contact block, 2 NO, 2.5 A","metaDescription":"Schneider GVAED1013 TeSys Deca auxiliary contact block: 2 NO contacts, 2.5 A switching current, front-mount spring terminal, for GV2/GV3 (except GV3ME). Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Auxiliary Contacts"],"specifications":{"Depth":"31.5 mm","Range":"TeSys TeSys Deca","Width":"44.5 mm","Colour":"Dark grey","Height":"13 mm","Standards":"EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-1:Clause 30.2 IEC/EN 60335-2-40:Annex JJ","Protection type":"GB2CB... circuit breaker GG fuse 10 A","lifecycle_stage":"current","Quantity per set":"Set of 1","Device short name":"GVAED","Mounting location":"Front side","Mechanical durability":"100000 cycles","Pole contact composition":"2 NO","Minimum switching current":"5 mA","Minimum switching voltage":"17 V","Product or component type":"Auxiliary contact block","Auxiliary contacts operation":"Fault signal 1 NO","Environmental characteristic":"Normal environment","Rated operational power in W":"120 W at 240 V DC-13 - electrical durability: 100000 cycles 140 W at 110 V DC-13 - electrical durability: 100000 cycles 140 W at 24 V DC-13 - electrical durability: 100000 cycles 180 W at 60 V DC-13 - electrical durability: 100000 cycles 240 W at 48 V DC-13 - electrical durability: 100000 cycles","Rated operational power in VA":"300 VA at 48 V AC-15 - electrical durability: 100000 cycles 400 VA at 690 V AC-15 - electrical durability: 100000 cycles 500 VA at 110...127 V AC-15 - electrical durability: 100000 cycles 500 VA at 500 V AC-15 - electrical durability: 100000 cycles 650 VA at 440 V AC-15 - electrical durability: 100000 cycles 720 VA at 230...240 V AC-15 - electrical durability: 100000 cycles 850 VA at 380...415 V AC-15 - electrical durability: 100000 cycles","[Ui] rated insulation voltage":"600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14","[Ue] rated operational voltage":"24...240 V AC 24...60 V DC","[Ith] conventional free air thermal current":"2.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$15.55","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e8b158e8b70c163d75efe45c4cec7818.pdf","sourceUrl":"https://www.se.com/ph/en/product/GVAED1013/addon-contact-blocktesys-deca-frame-2-31no+1nofaultfrontspring-terminalfor-gv2-gv3except-gv3me/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GVAED1013","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GVAED1013 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}