{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GVAS416","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GVAS416","canonicalUrl":"https://aoctrl.com/schneider/GVAS416","factsUrl":"https://aoctrl.com/api/mcp/products/GVAS416","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GVAS416 shunt trip release (MX), 415V AC 60Hz control circuit, 690V rated insulation, screw clamp terminals.","salesMarkdown":"The GVAS416 is a shunt trip release (MX) from the Schneider Electric TeSys Deca range, designed to remotely trip a TeSys motor starter on command. It operates on a 415 V AC 60 Hz control circuit and is rated for insulation up to 690 V AC per IEC 60947-1, with UL/CSA recognition at 600 V AC. The release mounts directly onto compatible TeSys Deca starters (GV2ME, GV2P, GV3P, GV3L). Dimensions are 18 mm wide, 89 mm high, 66 mm deep — a narrow footprint that fits into a crowded DIN-rail enclosure without stealing space from adjacent poles. Screw clamp terminals accept 1 to 2.5 mm² solid or 0.75 to 2.5 mm² flexible wire; torque to under 1.4 N·m. Mechanical durability is rated at 10,000 cycles with GV3P/GV3L and 30,000 cycles with GV2ME/GV2P. ## Electrical characteristics Inrush power is 10.5 W / 14 VA AC; holding power drops to 1.6 W / 5 VA AC after the coil seals. The control circuit operates between 0.7 and 1.1 times nominal voltage (Un), with a tripping threshold of 0.75 to 0.2 Un — meaning it will reliably drop out when the control voltage sags below about 311 V AC on a 415 V line. On-load factor is 100 %, so it can remain energized continuously without derating.","metaTitle":"Schneider GVAS416 TeSys Shunt Trip Release, 415V AC 60Hz","metaDescription":"GVAS416 shunt trip release (MX) for TeSys Deca motor starters. 415V AC 60Hz control voltage, 690V rated insulation. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"66 mm","Width":"18 mm","Height":"89 mm","Coil Voltage":"415 V AC 60 Hz","Operating Time":"10...15 ms conforming to IEC 60947-1","Product Status":"Active","Main Product Or Component Type":"Shunt trip release"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/78811ce43dee5b4561b78889769874d1.pdf","sourceUrl":"https://www.se.com/ae/en/product/GVAS416/shunt-release-mx-tesys-deca-415v-ac-60hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GVAS416/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GVAS416","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GVAS416 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}