{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"H3CR-AP AC24-48/DC12-48","brand":"Omron","brandSlug":"omron","productSlug":"H3CR-AP-AC24-48-DC12-48","canonicalUrl":"https://aoctrl.com/omron/H3CR-AP-AC24-48-DC12-48","factsUrl":"https://aoctrl.com/api/mcp/products/H3CR-AP%20AC24-48%2FDC12-48","rawCanonicalId":null},"summary":{"shortDescription":"Omron H3CR-A series H3CR-AP AC24-48/DC12-48 multi-function timer relay, DPDT (2 Form C), 0.05 sec to 300 hrs delay, 24 to 48 VAC / 12 to 48 VDC supply, 5 A at 250 VAC contact, 11-pin octal plug-in socket.","salesMarkdown":"## Multi-mode timing from a single octal-base module The Omron H3CR-AP AC24-48/DC12-48 sits in the H3CR-A line as a programmable multi-function timer covering 0.05 sec to 300 hrs of delay in one package — a single stock number absorbs the on-delay, interval, and cycle-mode selections a control panel usually spreads across three or four separate timer SKUs. Output is DPDT (2 Form C) via a mechanical relay rated 5 A at 250 VAC, and timing is started by applying input voltage to the supply pins — the function select dial and the time-range dial are set on the face before the 11-pin octal base is plugged into its matching socket. ## Wide-band supply and what 5 A actually switches Supply input accepts 24 to 48 VAC and 12 to 48 VDC on the same terminals — the same timer drops into a 24 VDC control cabinet, a 48 VDC battery-backed annunciator loop, or a 120 VAC-derived 24 VAC pilot circuit without re-specifying the part, which simplifies spares holding across mixed-voltage panels. The 5 A at 250 VAC contact rating governs resistive and lightly inductive loads at utility pilot levels — adequate for contactor coils, solenoid valves, and indicator lamps, but a real motor or heater load needs the rating read against the load's inrush and the expected cycle rate, because the mechanical-relay output sets the ceiling well below what a solid-state alternative would carry. ## Socket-mount form factor for panel builders Plug-in 11-pin octal termination into a panel-mounted socket means the timer body unclips for swap-out without disturbing the field wiring — a failed unit on a running line comes out, a spare drops in, and the wiring is left alone, which is the standard MRO pattern for this class of electromechanical timer. ## Lifecycle posture and the sourcing close Omron lists this part as active in the mature phase of the H3CR-A series, so production continues and the long-tail panel-builder demand for the 11-pin octal footprint is still being served from the factory channel. For a BOM line or a stocked spare, the order code is specified against the RFQ with current availability and pricing confirmed at quote time — no stock count or lead-time figure is asserted here.","metaTitle":"Omron H3CR-AP AC24-48/DC12-48 Timer, DPDT, 5A, 300 Hrs","metaDescription":"Omron H3CR-AP AC24-48/DC12-48 H3CR-A series multi-function timer, DPDT, 0.05s to 300hr range, 24-48 VAC / 12-48 VDC supply. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Electronic Timers & Counters"],"specifications":{"title":"H3CR-AP AC24-48/DC12-48","Series":"H3CR-A","Circuit":"DPDT (2 Form C)","Package":"Bulk","Function":"Programmable (Multi-Function)","Delay Time":"0.05 Sec ~ 300 Hrs","Relay Type":"Mechanical Relay","description":"RELAY TIME DELAY 300HRS 5A 250V","Mounting Type":"Socketable","lifecycle_stage":"mature","Voltage - Supply":"24 ~ 48VAC, 12 ~ 48VDC","Termination Style":"Plug In, 11 Pin (Octal)","Timing Initiate Method":"Input Voltage","Contact Rating @ Voltage":"5A @ 250VAC","Timing Adjustment Method":"Hand Dial"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$42.42","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a75e047eeeba0290910382e077df1c26.pdf","sourceUrl":null},"ai":{"faq":[{"question":"How do I get current pricing and availability for H3CR-AP AC24-48/DC12-48?","answer":"Price and stock are confirmed at quote time against the RFQ — the order code, the required quantity, and any traceable-lot or manufacturer-authorization requirements are specified into the request, and a current offer is returned. No list price, stock count, or ships-from figure is carried on the page itself."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/omron/H3CR-AP-AC24-48-DC12-48","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/H3CR-AP-AC24-48-DC12-48 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}