{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"H3YN-41 DC24","brand":"Omron","brandSlug":"omron","productSlug":"H3YN-41-DC24","canonicalUrl":"https://aoctrl.com/omron/H3YN-41-DC24","factsUrl":"https://aoctrl.com/api/mcp/products/H3YN-41%20DC24","rawCanonicalId":null},"summary":{"shortDescription":"Omron H3YN series multi-function timer relay, 24 VDC supply, 4PDT (4 Form C) contacts, 3 A at 250 VAC, 0.1 min to 10 hrs delay range, plug-in socket mount.","salesMarkdown":"## What the coil and contact set actually cover The H3YN-41 DC24 sits in Omron's H3YN series as a multi-function programmable timer, taking a 24 VDC supply on a plug-in base and switching a 4PDT (4 Form C) mechanical relay output. The four-pole Form C arrangement gives the installer two NO and two NC contact sets from one timing block — useful where a single timer has to release one load and pick up another after a programmed interval. Output contacts are rated 3 A at 250 VAC — the limit that matters when the timer drives a small contactor coil, a solenoid, or an indicator, not a motor contactor. For higher inrush or motor loads, the load should be switched through an interposing relay sized for the duty. ## Timing range, adjustment, and how it starts The delay window runs from 0.1 minutes to 10 hours, selected on a hand-dial face — the range covers a slow sequencing timer on a conveyor staging circuit as readily as a short process-interval timer on a wash cycle. Timing starts on applied input voltage, which keeps the wiring to a single start lead rather than a separate trigger terminal — the trade-off is that power loss resets the timer and the cycle restarts on re-energization. Multi-function programmability means one stock code covers on-delay, off-delay, interval, and cycle modes without committing the panel to four separate timer SKUs. ## Socket-mounting in the panel The relay drops onto a standard 8- or 11-pin octal-style socket — the socketable mount is what lets a worn timer be swapped in seconds without disturbing the field wiring, and it is the reason this part tends to ride the shelf as a critical spare rather than a build-only line item. Bulk packaging confirms the part is aimed at panel-build quantities rather than single-piece retail. ## Lifecycle and supply posture Omron lists the part as Active, while the catalog flags the series as mature — meaning the H3YN line continues in production but is not the latest generation Omron is pushing. For an MRO buyer this is a comfortable posture: the part is still factory-supported, spares will keep flowing, and the older series positioning suggests pricing has settled.","metaTitle":"Omron H3YN-41 DC24 Timer, 24VDC, 4PDT, 3A","metaDescription":"Omron H3YN-41 DC24 multi-function timer, 24 VDC coil, 4PDT contacts rated 3 A at 250 VAC, 0.1 min–10 hrs range. Active line, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Electronic Timers & Counters"],"specifications":{"title":"H3YN-41 DC24","Series":"H3YN","Circuit":"4PDT (4 Form C)","Package":"Bulk","Function":"Programmable (Multi-Function)","Delay Time":"0.1 Min ~ 10 Hrs","Relay Type":"Mechanical Relay","description":"RELAY TIME DELAY 10HRS 3A 250V","Mounting Type":"Socketable","lifecycle_stage":"mature","Voltage - Supply":"24VDC","Termination Style":"Plug In","Timing Initiate Method":"Input Voltage","Contact Rating @ Voltage":"3A @ 250VAC","Timing Adjustment Method":"Hand Dial"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$34.52","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/268681bf777f91cec7eb227e1fcf07c6.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What series and contact form does the H3YN-41 DC24 carry?","answer":"It belongs to the H3YN series and ships as a 4PDT (4 Form C) mechanical relay, so a single timing block exposes four independent poles — two NO and two NC — for sequencing multiple loads from one programmed interval."},{"question":"What timing range and adjustment method does this timer use?","answer":"The delay is set on a hand-dial face covering 0.1 minutes through 10 hours, and timing initiates on applied input voltage rather than a separate trigger terminal. Multi-function programmability covers on-delay, off-delay, interval, and cycle modes from one stock code."},{"question":"What is the contact rating and where does the H3YN-41 DC24 fit best in a panel?","answer":"Output contacts are rated 3 A at 250 VAC, which suits contactor or solenoid coils and indicator circuits rather than direct motor switching. The plug-in socket mount lets a failed timer be swapped in seconds without disturbing field wiring — a reason the part typically lives on the MRO shelf as a critical spare."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/omron/H3YN-41-DC24","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/H3YN-41-DC24 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}