{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"H7CZ-L8","brand":"Omron","brandSlug":"omron","productSlug":"H7CZ-L8","canonicalUrl":"https://aoctrl.com/omron/H7CZ-L8","factsUrl":"https://aoctrl.com/api/mcp/products/H7CZ-L8","rawCanonicalId":null},"summary":{"shortDescription":"Omron H7CZ-L8 1-stage preset digital counter, 100-240 VAC, 30 Hz / 10 kHz counting speed, increment/decrement input, flush or surface mount.","salesMarkdown":"The Omron H7CZ-L8 is a 1-stage preset digital counter built for panel-mount counting applications where you need a clean count signal and a reliable output at a set point. It accepts 100 to 240 VAC, 50/60 Hz, with a voltage fluctuation tolerance of 85% to 110% of rated supply. Power consumption runs about 9.4 VA at 100-240 VAC, or 7.2 VA / 4.7 W on 24 VAC or 12-24 VDC supply variants. Counting speed is switchable between 30 Hz and 10 kHz, with a 1:1 ON/OFF ratio. That 10 kHz rate handles fast-cycling parts on a pick-and-place or a high-speed packaging line; the 30 Hz position filters contact bounce on mechanical switches or relay outputs. Input mode is selectable for increment or decrement, so it works for both totalizing and countdown applications. ## Output modes and timing Output modes include N, F, C, R, K-1, P, Q, and A — these cover self-holding, one-shot, and batch-counting patterns common in batching or cut-to-length machines. One-shot output time is adjustable from 0.01 to 99.99 seconds, which lets you tailor the pulse width to a PLC input scan or a solenoid valve response. Reset can be external (minimum signal width selectable between 1 ms or 20 ms), manual, or automatic. The 1 ms setting works with fast PLC outputs; the 20 ms setting debounces a mechanical pushbutton. A prescaling function from 0.001 to 99.999 lets you scale encoder pulses to engineering units — useful for linear measurement with a rotary encoder. Mounts flush or surface on a panel. External connections go through an 8-pin socket, so wiring is a plug-in affair — swap the counter without pulling wires. Sensor waiting time is 290 ms max, which matters if you're cycling power to the counter between batches; the count input won't miss the first pulse after power-up. ## Environmental limits Operating humidity range is 25% to 85%.","metaTitle":"Omron H7CZ-L8 Digital Counter, 1-Stage Preset, 100-240 VAC","metaDescription":"Omron H7CZ-L8 1-stage preset digital counter. Mature lifecycle. 30 Hz or 10 kHz counting speed. 100-240 VAC supply. Increment/Decrement input. RFQ for sourcing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Weight":"0.1 Kg","Mounting":"Flush mounting or surface mounting","Input Mode":"Decrement, Increment","Output Mode":"N, F, C, R, K-1, P, Q, and A.","Product Type":"Digital Counter","Product Status":"Mature","Temp Storage Max":"70 °C","Temp Storage Min":"-25 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$94.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/82770a62c2f3eeb073594fd74cbb7f6f.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/H7CZ-L8/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/omron/H7CZ-L8","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/H7CZ-L8 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}