{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"HGF26125SO","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"HGF26125SO","canonicalUrl":"https://aoctrl.com/schneider/HGF26125SO","factsUrl":"https://aoctrl.com/api/mcp/products/HGF26125SO","rawCanonicalId":null},"summary":{"shortDescription":"MOLDED CASE CIRCUIT BREAKER 600V 125A|MOLDED CASE CIRCUIT BREAKER 600V 125A","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"Black","Depth":"3.4 in (86 mm)","Range":"PowerPact","Width":"4.09 in (104 mm)","Height":"6.4 in (163 mm)","Category":"US10DE201115","AWG gauge":"AWG 14...AWG 3/0 aluminium/copper terminal","Standards":"UL CSA NEMA NOM-003-SCFI-2000 IEC 60947-2","Control Type":"Toggle","Product name":"PowerPact H","Mounting mode":"Unit mount busbar)","Quality labels":"CE","Number of Poles":"2P","Number of slots":"2 auxiliary switch OF plug-in) 1 alarm switch SD plug-in) 1 overcurrent trip switch SDE plug-in) 1 voltage release MN or MX plug-in)","lifecycle_stage":"unknown","Local signalling":"Switched off (OFF) 1 trip indicator green)","Mounting Support":"Busbar","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Breaking capacity":"65 kA 240 V AC 50/60 Hz UL 489 35 kA 480 V AC 50/60 Hz UL 489 18 kA 600 V AC 50/60 Hz UL 489 20 kA 250 V DC UL 489 20 kA 500 V DC UL 489","Network Frequency":"50/60 Hz","Tightening torque":"44.3 lbf.in (5 N.m) 0.004...0.009 in² (2.5...6 mm²) (AWG 14...AWG 10) 123.9 lbf.in (14 N.m) 0.02...0.1 in² (10...95 mm²) (AWG 8...AWG 3/0)","Device Application":"Distribution","Line Rated Current":"125 A","Operating altitude":"< 6561.68 ft (2000 m) without derating 5000 m with derating","Terminal identifier":"AL150HD","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical connection":"Busbar connection, line Busbar connection, load","Magnetic hold current":"900 A","Nbr. of units in pkg.":"1","Breaking capacity code":"G","Communication interface":"Modbus Ethernet","IP degree of protection":"Front cover IP40 IEC 60529","Continuous current rating":"80 %","Magnetic tripping current":"1700 A","Product or Component Type":"Circuit breaker","Suitability for isolation":"Yes IEC 60947-2","Circuit breaker application":"HACR rated","Power wire stripping length":"0.6 in (16 mm)","Protected poles description":"2t","[Ui] rated insulation voltage":"750 V IEC 60947-2","Accessory / separate part type":"Shunt trip 24 V DC compartment","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-3","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Ics] rated service breaking capacity":"65 kA 220/240 V AC 50/60 Hz IEC 60947-2 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 20 kA 250 V DC IEC 60947-2 20 kA 500 V DC IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8d8405528ac8c5ed13f0e5ddf13cabfb.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/HGF26125SO/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/HGF26125SO","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/HGF26125SO when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}