{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"HL2IMA12C1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"HL2IMA12C1","canonicalUrl":"https://aoctrl.com/schneider/HL2IMA12C1","factsUrl":"https://aoctrl.com/api/mcp/products/HL2IMA12C1","rawCanonicalId":null},"summary":{"shortDescription":"Square D HL2IMA12C1 Surge Protection Device|Square D HL2IMA12C1 Surge Protection Device","salesMarkdown":null,"metaTitle":"Schneider HL2IMA12C1 Surge Protection Device","metaDescription":"Schneider HL2IMA12C1 surge protection device for I-Line panelboard applications.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"MCOV":"150 V","SCCR":"200 kA","Type":"HL","Depth":"5.6 in (142.1 mm)","Range":"Surgelogic","Width":"13.5 in (341.9 mm)","Height":"12.2 in (308.9 mm)","Product":"Surge protection device","Category":"US1DE1B08460","Standards":"UL 1449:ed. 3 CSA C22.2 No 8:1986 UL 96A:ed. 12 UL 489:ed. 11 CSA C22.2 No 5-09","Connection":"I-Line line Lugs ground AWG 6 copper 35.4 lbf.in (4 N.m) Lugs neutral AWG 6 copper 35.4 lbf.in (4 N.m)","Cable length":"19.02 in (483 mm)","Rated Current":"60 A","Surge Current":"120 kA","Voltage Rating":"208Y/120 V AC","lifecycle_stage":"unknown","Enclosure Rating":"NEMA 1","Local Signalling":"Status LED green per phase normal operation Status LED red per phase fault","Mounting Support":"Panel mounting","Number of Phases":"3 phase","Breaking Capacity":"50 kA","Device Short Name":"IMA","Provided Equipment":"Alarm enable/disable switch Surge counter Circuit-breaker","Max Number of Poles":"3","Trip Unit Technology":"Thermal-magnetic","Wiring Configuration":"4-wire","Nbr. of units in pkg.":"1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d0172f229099fb088305e71c194981f9.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/HL2IMA12C1/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/HL2IMA12C1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/HL2IMA12C1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}