{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"HMIBSCEA53D1EM30","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"HMIBSCEA53D1EM30","canonicalUrl":"https://aoctrl.com/schneider/HMIBSCEA53D1EM30","factsUrl":"https://aoctrl.com/api/mcp/products/HMIBSCEA53D1EM30","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EcoStruxure EV Charging Expert EV charge controller, HMIBSCEA53D1EM30, 30 charging stations, 60 charge points, 5 zones, dynamic load management, IP40, 12-24 V DC supply.","salesMarkdown":"The Schneider Electric HMIBSCEA53D1EM30 is an EcoStruxure EV Charging Expert EV charge controller that manages up to 30 charging stations and 60 charge points across 5 zones with dynamic load management. It's the brain for a commercial EV charging site — decides how much juice each vehicle gets based on the building's total capacity. Dynamic load management means this controller talks to the building's energy meter and throttles charging stations in real time — no tripping the main breaker when a fleet of trucks all plug in at shift change. The 5-zone limit lets you group parking bays by priority (e.g., fast-charge for delivery vans, slow overnight for employee cars). IP40 means it's indoor-only — fine for a panel in a parking garage electrical room, but don't mount it under a canopy exposed to rain. Wall or DIN-rail mount with horizontal or vertical orientation. The 157 x 150 x 46 mm footprint fits a standard 4-module DIN enclosure. Supply it with 12-24 V DC at 16 W — a standard industrial PSU handles that. The modem 3G/4G and the energy meter are ordered separately, so budget for those line items. Ethernet RJ45 Cat.6 connects to the PC for setup, and a second RJ45 talks to the charging station LAN. OCPP 1.6J keeps it compatible with central management systems.","metaTitle":"Schneider HMIBSCEA53D1EM30 EV Charge Controller, 30 Stations","metaDescription":"Schneider Electric HMIBSCEA53D1EM30 EcoStruxure EV Charging Expert controller. Active production. Manages 30 charging stations, 60 charge points, 5 zones. Dynamic load management.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["HMI Operator Interfaces"],"specifications":{"Depth":"46 mm","Range":"EcoStruxure EV Charging Expert","Width":"157 mm","title":"HMIBSCEA53D1EM30","Height":"150 mm","Services":"Commercial service plan 0...50 °C","Standards":"EN/IEC 61131-2 EN 55011 EN/IEC 61000-6-4","Input type":"Energy meter","description":"EV charge controller, EcoStruxure EV Charging Expert, 30 charging stations, Schneider Charge Pro, 5 zones, dynamic load management","OCPP version":"Latest available version","Product name":"EcoStruxure EV Charging Expert","Mounting mode":"Wall mount","Load Management":"Dynamic","Max Nb Of Zones":"5","lifecycle_stage":"current","Installed device":"Modem 3G/4G (to be ordered separately) Meter device (to be ordered separately)","Mounting support":"DIN rail","Targeted country":"All","Mounting position":"Horizontal/vertical","Relative humidity":"10...95 %","Device application":"To manage the overall energy allocated to each vehicle","Operating altitude":"0...2000 m","Functions Selection":"Without priority charging profile With time-of-use settings Without PV integration Without BEMS integration via API Without authentication via badges Without transaction logs","Type of installation":"Indoor","Communication service":"Web server for HTTPS Web server for OCPP 1.6J","Max Nb Of Zone Levels":"3","Power consumption in W":"16 W","Communication interface":"Ethernet RJ45 Cat.6 to connect device to PC Ethernet RJ45 to connect device to charging station Modem to connect device to central management system","IP degree of protection":"IP40","Product or component type":"EV charge controller","[Us] rated supply voltage":"12...24 V DC","Max Managed Charging Points":"60 charge points","Electromagnetic compatibility":"Conducted and radiated emissions class A conforming to EN 55022","Max Managed Charging Stations":"30 charging stations","Ambient air temperature for storage":"-20...60 °C","Ambient air temperature for operation":"0...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ee850d00cf78a0d5bd130ceedf978d8e.pdf","sourceUrl":"https://www.se.com/vn/en/product/HMIBSCEA53D1EM30/ev-charge-controller-ecostruxure-ev-charging-expert-30-charging-stations-schneider-charge-pro-5-zones-dynamic-load-management/"},"ai":{"faq":[{"question":"What compliance standards does HMIBSCEA53D1EM30 meet?","answer":"It complies with EN/IEC 61131-2 (programmable controllers), EN 55011 (industrial emissions), and EN/IEC 61000-6-4 (immunity for industrial environments). Conducted and radiated emissions are Class A per EN 55022."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/HMIBSCEA53D1EM30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/HMIBSCEA53D1EM30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}