{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ILA2P571PB2A0","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ILA2P571PB2A0","canonicalUrl":"https://aoctrl.com/schneider/ILA2P571PB2A0","factsUrl":"https://aoctrl.com/api/mcp/products/ILA2P571PB2A0","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Lexium integrated drive ILA2P571PB2A0, AC synchronous servo motor, 57 mm flange, 0.44 N.m nominal torque, 24–48 V DC, multi-turn encoder, CE.","salesMarkdown":"## 0.44 N.m at 3200 rpm on a 57 mm integrated drive The Schneider Electric ILA2P571PB2A0 sits inside the Lexium integrated drive ILA family as an AC synchronous servo motor with a 57 mm mounting flange, a multi-turn encoder and a 6-pole rotor — sized for medium-speed, medium-torque axes where the drive electronics live on the motor itself rather than in a cabinet-mounted amplifier. Continuous rating is 0.44 N.m of nominal torque with a peak stall of 0.62 N.m, and the speed envelope is 3200 rpm at 24 V supply rising to 5100 rpm at 48 V — so the same motor can be run harder simply by lifting the DC bus, provided the application stays inside the integrated protection set. ## DC bus, current draw and what the integrated protections cover The motor takes a 24–48 V DC supply (operating limits 18–55.2 V) and draws up to 5000 mA continuous with a 7000 mA peak; the recommended branch protection is a 16 A fuse — sized for the peak inrush rather than the continuous figure. ## Shaft, feedback and I/O for the control loop The shaft is 9 mm diameter, 20 mm long, untapped and without a second shaft end — the load couples directly through a single keyed or pinned element, and there is no gearbox and no holding brake in this configuration. Four signals are exposed as programmable inputs or outputs through a printed circuit board connector, and the communication link runs at 100 Mbit/s — enough for cyclic setpoint updates from a Lexium controller or a third-party motion master without an additional gateway. ## Mounting, environment and the standards stack The motor flange-mounts to the machine with a 1.6 mm centring collar depth, accepts up to 104 N of axial force in either pressure or tension, and the overall length is 189.3 mm — dimensions that let it drop into a typical 57 mm cut-out on an indexer, a labelling head or a small linear actuator. Mechanical endurance is rated for 150 m/s² shock (1000 shocks) and 20 m/s² vibration across 10–500 Hz, both to the EN/IEC 60068-2 test methods, with a 20 000 h bearing service life — so the planned maintenance interval is set by the bearings, not by the electronics. Discrete inputs draw 10 mA at 24 V on the safety channel and 2 mA at 24 V on the standard signal interface — useful when sizing the 24 V rail that feeds both the logic and the safe-torque-off input. ## BOM-line sourcing posture Lifecycle is recorded as current, so ILA2P571PB2A0 stays on the active Schneider Electric Lexium integrated drive ILA line — independent distribution sources it to order against the BOM, and pricing is confirmed at RFQ rather than carried as a public list figure.","metaTitle":"Schneider ILA2P571PB2A0 servo motor, 57 mm, 0.44 N.m","metaDescription":"Schneider Electric ILA2P571PB2A0 Lexium integrated drive ILA AC synchronous servo motor, 57 mm flange, 0.44 N.m nominal, CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Servo Motors with Brake"],"specifications":{"title":"ILA2P571PB2A0","Length":"189.3 mm","Marking":"CE","Shaft end":"Untapped","Standards":"EN 61800-3 : 2001-02 EN 50347 IEC 60072-1 EN/IEC 61800-3 EN/IEC 50178 EN 61800-3:2001, second environment IEC 61800-3, Ed 2","Motor type":"AC synchronous servo motor","description":"integrated drive ILA with servo motor - 24..48 V - Ethernet Powerlink - PCB conn","Network type":"DC","Second shaft":"Without second shaft end","Shaft length":"20 mm","Winding type":"Medium speed of rotation and medium torque","Feedback type":"Multi turn encoder","Gear box type":"Without","Holding brake":"Without","Nominal speed":"3200 rpm at 24 V 5100 rpm at 48 V","Rotor inertia":"0.095 kg.cm²","Accuracy error":"+/- 0.05 °","Nominal torque":"0.44 N.m","Shaft diameter":"9 mm","Protection type":"Short circuit of the output voltage Safe torque off Overload of output voltage","Type of cooling":"Natural convection","lifecycle_stage":"current","Mounting support":"Flange","Range of product":"Lexium integrated drive","Shock resistance":"150 m/s² 1000 shocks conforming to EN/IEC 60068-2-29","Device short name":"ILA","Input/output type":"4 signals (each be used as input or output)","Motor flange size":"57 mm","Peak stall torque":"0.62 N.m","Relative humidity":"15...85 % without condensation","Transmission rate":"100 Mbits","Operating altitude":"<= 1000 m without derating","Current consumption":"5000 mA maximum continuous 7000 mA peak","Vibration resistance":"20 m/s² (f= 10...500 Hz) 10 cycles conforming to EN/IEC 60068-2-6","Centring collar depth":"1.6 mm","Electrical connection":"Printed circuit board connector","Number of motor poles":"6","Service life in hours":"20000 h bearing","Supply voltage limits":"18...55.2 V","Associated fuse rating":"16 A","Discrete input current":"10 mA at 24 V for safety input 2 mA at 24 V for 24 V signal interface","Maximum axial force Fa":"104 N (force pressure) 104 N (tensile force)","Number of motor stacks":"1","Commissioning interface":"RS485 Modbus TCP (9.6, 19.2 and 38.4 kbauds)","Communication interface":"Ethernet Powerlink, integrated","Continuous stall torque":"0.44 N.m","Discrete output voltage":"23...25 V","IP degree of protection":"IP41 shaft bushing: conforming to EN/IEC 60034-5 IP54 total except shaft bushing: conforming to EN/IEC 60034-5","Maximum radial force Fr":"89 N","Mounting holes diameter":"5.2 mm","Centring collar diameter":"50 mm","Network number of phases":"Single phase","Number of mounting holes":"4","Maximum switching current":"100 mA per output 200 mA total","Product or component type":"Motion integrated drive","Speed feedback resolution":"16384 points/turn x 4096 turns","[Us] rated supply voltage":"48 V 24 V","Voltage state 0 guaranteed":"-3...4.5 V","Voltage state 1 guaranteed":"15...30 V","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"40...55 °C (with power derating of 2 % per °C) 0...40 °C (without derating)","Circle diameter of the mounting holes":"66.6 mm","Permissible ambient air temperature around the device":"105 °C power amplifier 110 °C motor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c69eaf23aad76606b0ea28782bce06d0.pdf","sourceUrl":"https://www.se.com/za/en/product/ILA2P571PB2A0/integrated-drive-ila-with-servo-motor-24-48-v-ethernet-powerlink-pcb-conn/"},"ai":{"faq":[{"question":"What is the ILA2P571PB2A0's listed length on this Servo Motors line?","answer":"The ILA2P571PB2A0 is listed at 189.3 mm overall length with a 57 mm flange, a 1.6 mm centring collar depth and a 9 mm × 20 mm untapped shaft — so it fits the standard 57 mm cut-out footprint used across the Lexium integrated drive ILA family."},{"question":"What compliance documentation covers the ILA2P571PB2A0?","answer":"The ILA2P571PB2A0 carries CE marking and is declared against EN 61800-3: 2001-02 (second environment), EN/IEC 61800-3, EN/IEC 50178, EN 50347 and IEC 60072-1 — the stack that covers industrial drive EMI, electrical safety for power drive systems, rotating-machine dimensions and general CE conformity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ILA2P571PB2A0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ILA2P571PB2A0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}