{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ILA2P572PC1A0","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ILA2P572PC1A0","canonicalUrl":"https://aoctrl.com/schneider/ILA2P572PC1A0","factsUrl":"https://aoctrl.com/api/mcp/products/ILA2P572PC1A0","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Lexium integrated drive, ILA family, AC synchronous servo motor, single phase, 57 mm flange, 0.78 N.m nominal torque, 18–55.2 V DC supply.","salesMarkdown":"## Lexium ILA — drive and motor in one 57 mm housing The ILA2P572PC1A0 is a Schneider Electric Lexium integrated drive from the ILA family — an AC synchronous servo motor with the drive electronics co-located in the same housing rather than in a separate cabinet. It belongs to the Lexium integrated drives line and drops into a 57 mm motor flange footprint, which is the standard NEMA-style small-frame servo envelope for indexing tables, light conveyors and laboratory automation. The supply is single-phase on a DC bus rated 18–55.2 V, which puts it in the low-voltage motion class rather than the 230/400 V three-phase servo tier — drive sizing must respect that bus window or the integrated electronics will not start. ## Torque, speed and current — what 0.78 N.m buys you Nominal torque is 0.78 N.m with a peak stall of 1.62 N.m and nominal speed of 1600 rpm at 24 V rising to 3400 rpm at 48 V. On the 48 V rail you get more than double the speed headroom of the 24 V rail — for cycle-time-critical applications the bus voltage selection matters as much as the motor selection. Continuous current draw is 7 A with a peak of 8.5 A, which is the figure that determines whether the upstream 24 V or 48 V supply, fusing and wiring gauge are adequate — peak demand arrives during acceleration and must not starve the DC bus. Positioning accuracy is +/- 0.05° from the single-turn encoder feedback — tight enough for indexing and registration duty without pushing the cost of a multi-turn absolute encoder. ## Shaft, flange and mechanical envelope The motor flange is 57 mm with a centring collar depth of 1.6 mm and a 9 mm untapped shaft running 20 mm long. No second shaft and no gearbox — coupling selection and mounting bracket design are driven entirely by this 57 mm bolt circle. The body is 163.8 mm long and shock/vibration rated to 150 m/s² (1000 shocks) and 20 m/s² (10–500 Hz) per EN/IEC 60068-2, so it survives on machine frames with gear-head side loads as long as the coupling is misalignment-tolerant. Cooling is natural convection with no integrated fan — derating starts above the 1000 m altitude ceiling unless the datasheet's thermal curve is consulted for the specific duty cycle. ## Holding brake, safety and protection This variant ships without a holding brake, so a vertical axis that needs to hold position under gravity must use an external failsafe brake or a counterbalance — do not assume the ILA family always brakes itself. Onboard protection covers output short circuit, Safe Torque Off (STO) and output voltage overload, with the four signal lines configurable as input or output — STO simplifies the safety circuit on collaborative cells where a category-1 stop is acceptable. ## Compliance, environment and service life Marked CE and qualified to IEC 60072-1, EN 61800-3 (second environment), EN/IEC 50178, EN 50347 and IEC 61800-3 Ed 2 — the EN 61800-3 second-environment rating is the figure that decides whether it can sit on the industrial floor of a plant without extra EMC filtering on the line side.","metaTitle":"Schneider ILA2P572PC1A0 Lexium Integrated Drive, 57 mm","metaDescription":"Schneider Electric ILA2P572PC1A0 Lexium integrated drive: 57 mm flange, 0.78 N·m nominal / 1.62 N·m peak, 18–55.2 V DC bus. CE, IEC/EN listed. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Servo Motors with Brake"],"specifications":{"Phase":"Single phase","Length":"6.4 in (163.8 mm)","Marking":"CE","Category":"18288 - LEXIUM INTEGRATED DRIVES II","Shaft end":"Untapped","Standards":"IEC 60072-1 EN 61800-3 : 2001-02 EN/IEC 50178 EN 61800-3:2001, second environment EN/IEC 61800-3 IEC 61800-3, Ed 2 EN 50347","Motor Type":"AC Synchronous Servo Motor","Network type":"DC","Second shaft":"Without second shaft end","Shaft length":"0.8 in (20 mm)","Winding type":"Medium speed of rotation and medium torque","Feedback type":"Single turn encoder","Gear box type":"Without","Holding brake":"Without","Nominal speed":"1600 rpm 24 V 3400 rpm 48 V","Rotor inertia":"0.173 kg.cm²","Accuracy error":"+/- 0.05 °","Nominal torque":"6.90 lbf.in (0.78 N.m)","Shaft diameter":"0.4 in (9 mm)","Protection Type":"Short circuit of the output voltage Safe torque off Overload of output voltage","Type of cooling":"Natural convection","lifecycle_stage":"current","Mounting Support":"Flange","Range of Product":"Lexium integrated drive","Shock resistance":"150 m/s² 1000 shocks EN/IEC 60068-2-29","Device short name":"ILA","Input/output type":"4 signals (each be used as input or output)","Motor flange size":"2.2 in (57 mm)","Peak stall torque":"14.34 lbf.in (1.62 N.m)","Relative humidity":"15...85 % without condensation","Transmission Rate":"100 Mbits","Operating altitude":"<= 3280.84 ft (1000 m) without derating","Current consumption":"7000 mA maximum continuous 8500 mA peak","Vibration resistance":"20 m/s² 10...500 Hz) 10 cycles EN/IEC 60068-2-6","Centring collar depth":"0.06 in (1.6 mm)","Electrical Connection":"Industrial connector","Nbr. of units in pkg.":"1","Number of motor poles":"6","Service life in hours":"20000 h bearing","Supply voltage limits":"18...55.2 V","Associated fuse rating":"16 A","Discrete input current":"10 mA at 24 V safety input 2 mA at 24 V 24 V signal interface","Maximum axial force Fa":"104 N force pressure) 104 N tensile force)","Number of motor stacks":"2","Commissioning interface":"RS485 Modbus TCP 9.6, 19.2 and 38.4 kbauds)","Communication interface":"Ethernet Powerlink, Integrated","Continuous stall torque":"6.90 lbf.in (0.78 N.m)","Discrete output voltage":"23...25 V","IP degree of protection":"IP41 shaft bushing: conforming to EN/IEC 60034-5 IP54 total except shaft bushing: conforming to EN/IEC 60034-5","Maximum radial force Fr":"107 N","Mounting holes diameter":"0.2 in (5.2 mm)","Centring collar diameter":"2.0 in (50 mm)","Number of mounting holes":"4","Maximum switching current":"100 mA per output 200 mA total","Product or Component Type":"Motion integrated drive","Speed feedback resolution":"16384 points/turn","[Us] rated supply voltage":"24 V 48 V","Voltage state 0 guaranteed":"-3...4.5 V","Voltage state 1 guaranteed":"15...30 V","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Ambient air temperature for operation":"104...131 °F (40...55 °C) (with power derating of 2 % per °C) 32...104 °F (0...40 °C) (without derating)","Circle diameter of the mounting holes":"2.6 in (66.6 mm)","Permissible ambient air temperature around the device":"221 °F (105 °C) power amplifier 230 °F (110 °C) motor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ce0df15a04961356731db3942c05c189.pdf","sourceUrl":"https://www.se.com/vn/en/product/ILA2P572PC1A0/integrated-drive-ila-with-servo-motor-24-48v-ethernet-powerlink-indus-conn/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ILA2P572PC1A0/alternatives.json"},"ai":{"faq":[{"question":"What is the listed phase and supply on the ILA2P572PC1A0?","answer":"The drive is rated single phase on a DC bus with supply limits of 18–55.2 V. It is not a 230/400 V three-phase servo — confirm the upstream 24 V or 48 V rail and fusing before specifying."},{"question":"What torque and speed does the ILA2P572PC1A0 deliver?","answer":"Nominal torque is 0.78 N.m with a peak stall of 1.62 N.m. Nominal speed is 1600 rpm at 24 V and 3400 rpm at 48 V — the bus voltage chosen is what unlocks the higher speed band."},{"question":"Does the ILA2P572PC1A0 have a holding brake?","answer":"No — this variant is supplied without a holding brake. A vertical axis needing gravity-hold must use an external failsafe brake."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ILA2P572PC1A0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ILA2P572PC1A0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}