{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ILA2T571TB1A0","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ILA2T571TB1A0","canonicalUrl":"https://aoctrl.com/schneider/ILA2T571TB1A0","factsUrl":"https://aoctrl.com/api/mcp/products/ILA2T571TB1A0","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Lexium ILA2T571TB1A0, AC synchronous servo motor, 57 mm flange, 0.31 N.m nominal torque, 24/48 VDC bus, single-turn encoder.","salesMarkdown":"## Sizing the ILA for a 24/48 VDC motion axis The ILA2T571TB1A0 is the AC synchronous servo member of the Schneider Lexium integrated drive line (ILA short name, Lexium integrated drive range), built around a 57 mm flange and a single-turn encoder for commutation feedback. It draws 7500 mA maximum continuous and peaks at 11000 mA, which fixes the DC-bus sizing: at 24 V the nominal speed is 5000 rpm and climbs to 7000 rpm at 48 V — pick the supply rail first, then the motion profile. ## Mechanical fit and shaft interface Mounting is flange-supported with a 57 mm motor flange, and the shaft end is untapped — couplings or mounted elements need a clamping-hub style fastening rather than a setscrew on the shaft thread. Shaft diameter is 9 mm with a 20 mm shaft length, and the centring collar depth is 1.6 mm — verify the mating pulley or pinion bore and keyway before committing the BOM line. Body length is 145.3 mm, so the cut-out and clearance for the gear-side accessory must accommodate the short-block footprint of the ILA family. ## I/O, feedback, and what the drive tells you Feedback is a single-turn encoder — sufficient for absolute position within one revolution, which simplifies homing on power-up but is not a multi-turn replacement; confirm the application does not require retained position across power cycles. Four signals are available as input or output, so the same physical pin serves either role depending on configuration — plan the wiring diagram with the four-channel budget, not against a fixed direction. Network type is DC and electrical connection is via a printed circuit board connector — the drive is intended to drop onto a mating PCB rather than accept discrete cabling on the motor housing. ## Protective functions and ambient envelope Protection covers output voltage overload, safe torque off, and output short circuit — safe torque off is the functional stop the integrator relies on for guard-door release, not just an overcurrent trip. Cooling is natural convection — no fan to fail in service, but the rated torque holds only if the housing sees unobstructed airflow; inside a sealed cabinet the derating curve on the product drawing applies. Operating altitude is 1000 m without derating, relative humidity 15 to 85 percent non-condensing, vibration resistance 20 m/s² across 10 to 500 Hz, and shock resistance 150 m/s² for 1000 shocks — within the IEC 60068-2 envelope for industrial panels. Bearing service life is rated at 20000 h — the L10 figure rather than an MTBF figure, and is the limit that drives preventive replacement on high-cycle lines. ## Standards the integrator has to clear The ILA2T571TB1A0 is marked CE and listed against IEC 60072-1 for mounting dimensions, EN/IEC 61800-3 for EMC in the second environment, EN 50347 for motor dimensions, and EN/IEC 50178 for power drive systems — the standards the panel builder certifies against rather than a regional UL file. Note the absence of an explicit UL listing in this evidence bundle — for North American UL 508A panel builds, confirm acceptance through the local inspector rather than assuming the CE mark transfers. ## Ordering posture for this line For a tail-spend consolidator, the right play is to put this order code on the preferred-supplier punch-out so the next PO is one-click rather than a one-off requisition — same quoted-to-order economics, lower cost per PO.","metaTitle":"ILA2T571TB1A0 Schneider Lexium Drive, 0.31 N.m","metaDescription":"Schneider Electric ILA2T571TB1A0 Lexium integrated drive, 57 mm flange AC servo motor, 0.31 N.m nominal, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Servo Motors with Brake"],"specifications":{"Phase":"Single phase","Length":"5.7 in (145.3 mm)","Marking":"CE","Category":"18288-LEXIUM INTEGRATED DRIVES II","Shaft end":"Untapped","Standards":"IEC 60072-1 EN/IEC 61800-3 EN 50347 IEC 61800-3, Ed 2 EN 61800-3:2001, second environment EN/IEC 50178 EN 61800-3 : 2001-02","Motor Type":"AC Synchronous Servo Motor","Network type":"DC","Second shaft":"Without second shaft end","Shaft length":"0.8 in (20 mm)","Winding type":"High speed of rotation and medium torque","Feedback type":"Single turn encoder","Gear box type":"Without","Holding brake":"Without","Nominal speed":"5000 rpm 24 V 7000 rpm 48 V","Rotor inertia":"0.095 kg.cm²","Accuracy error":"+/- 0.05 °","Nominal torque":"2.74 lbf.in (0.31 N.m)","Shaft diameter":"0.4 in (9 mm)","Protection Type":"Overload of output voltage Safe torque off Short circuit of the output voltage","Type of cooling":"Natural convection","lifecycle_stage":"current","Mounting Support":"Flange","Range of Product":"Lexium integrated drive","Shock resistance":"150 m/s² 1000 shocks EN/IEC 60068-2-29","Device short name":"ILA","Input/output type":"4 signals (each be used as input or output)","Motor flange size":"2.2 in (57 mm)","Peak stall torque":"3.98 lbf.in (0.45 N.m)","Relative humidity":"15...85 % without condensation","Transmission Rate":"10, 100 Mbits","Operating altitude":"<= 3280.84 ft (1000 m) without derating","Current consumption":"11000 mA peak 7500 mA maximum continuous","Vibration resistance":"20 m/s² 10...500 Hz) 10 cycles EN/IEC 60068-2-6","Centring collar depth":"0.06 in (1.6 mm)","Electrical Connection":"Printed circuit board connector","Nbr. of units in pkg.":"1","Number of motor poles":"6","Service life in hours":"20000 h bearing","Supply voltage limits":"18...55.2 V","Associated fuse rating":"16 A","Discrete input current":"10 mA at 24 V safety input 2 mA at 24 V 24 V signal interface","Maximum axial force Fa":"104 N force pressure) 104 N tensile force)","Number of motor stacks":"1","Commissioning interface":"RS485 Modbus TCP 9.6, 19.2 and 38.4 kbauds)","Communication interface":"Modbus TCP, Integrated","Continuous stall torque":"2.74 lbf.in (0.31 N.m)","Discrete output voltage":"23...25 V","IP degree of protection":"IP41 shaft bushing: conforming to EN/IEC 60034-5 IP54 total except shaft bushing: conforming to EN/IEC 60034-5","Maximum radial force Fr":"89 N","Mounting holes diameter":"0.2 in (5.2 mm)","Centring collar diameter":"2.0 in (50 mm)","Number of mounting holes":"4","Maximum switching current":"100 mA per output 200 mA total","Product or Component Type":"Motion integrated drive","Speed feedback resolution":"16384 points/turn","[Us] rated supply voltage":"24 V 48 V","Voltage state 0 guaranteed":"-3...4.5 V","Voltage state 1 guaranteed":"15...30 V","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Ambient air temperature for operation":"104...131 °F (40...55 °C) (with power derating of 2 % per °C) 32...104 °F (0...40 °C) (without derating)","Circle diameter of the mounting holes":"2.6 in (66.6 mm)","Permissible ambient air temperature around the device":"221 °F (105 °C) power amplifier 230 °F (110 °C) motor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4eba3d53714cac23abafb7f126ba4c81.pdf","sourceUrl":"https://www.se.com/us/en/product/ILA2T571TB1A0/integrated-drive-ila-with-servo-motor-24-48-v-modbus-tcp-pcb-connector/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ILA2T571TB1A0/alternatives.json"},"ai":{"faq":[{"question":"What is the listed phase and length for ILA2T571TB1A0?","answer":"Phase is single phase and body length is 145.3 mm (5.7 in) on the ILA2T571TB1A0 — figures read straight off the spec sheet for this 57 mm flange variant."},{"question":"What compliance documentation does Schneider Electric provide for ILA2T571TB1A0?","answer":"The ILA2T571TB1A0 carries CE marking and is cited against IEC 60072-1, EN/IEC 61800-3, EN 50347, and EN/IEC 50178. No UL file number appears in this evidence bundle — confirm North American acceptance through the local authority having jurisdiction before panel build."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ILA2T571TB1A0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ILA2T571TB1A0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}