{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ILE2P661PB1A4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ILE2P661PB1A4","canonicalUrl":"https://aoctrl.com/schneider/ILE2P661PB1A4","factsUrl":"https://aoctrl.com/api/mcp/products/ILE2P661PB1A4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Lexium ILE ILE2P661PB1A4 integrated brushless DC servo drive, 12 N.m nominal torque, 115:1 gear reduction, 66 mm flange, 24/48 VDC, CE marked.","salesMarkdown":"## What you're actually bolting to the panel The ILE2P661PB1A4 sits in the Lexium ILE integrated-drive family — a brushless DC motor, straight-tooth four-stage gearhead, and drive electronics in one 66 mm flange package. Winding is the medium-speed / medium-torque variant, so it lands in conveyor indexing, valve actuation, and small-format dosing lines rather than high-rpm spindle service. Output is a keyed shaft, 10 mm diameter by 25 mm long with a 16 mm key, no holding brake and no second shaft end — the load holds position through the gear alone when power drops. ## Headline ratings — what 12 N.m at 44 rpm actually buys you Nominal torque is 12 N.m at both 24 V and 48 V, so the motor runs the same duty point off either supply — useful when the cabinet has 24 VDC already and a 48 V tap isn't available. Nominal speed shifts with the rail: 35 rpm at 24 V, 44 rpm at 48 V. That's the gearhead output, not the motor shaft — the 115:1 reduction (3675:32) drops a much faster BLDC down to usable indexing speeds. Peak stall torque tops out at 24.72 N.m on either supply, roughly 2x nominal — the headroom for breakaway on a sticky valve or jammed conveyor flight before the drive folds back. Continuous output power is 54 W at 24 V and 68 W at 48 V. The rating that actually governs a slow indexer is the torque envelope, not the watts — pick by load inertia and cycle time first. ## Drive electronics and the bits you'll wire to Logic and power land through a printed-circuit board connector — no separate cabling harness to chase, and the I/O block exposes 4 signals each configurable as input or output. Built-in protection covers output short circuit, output overload, and safe torque off — the STO function lets you hard-wire a guard door into the drive without a separate safety relay. Peak current draw is 7000 mA, continuous max 5500 mA — the upstream 24 V or 48 V supply has to be sized for the inrush on every move profile, not the average draw. Cooling is natural convection only — no fan to fail, but the motor flange and surrounding panel metal become the heatsink and the cabinet layout needs to leave clearance around the body. ## Gearhead precision and how long the bearings actually last Accuracy is rated at +/- 0.5 point — fine for open-loop indexing where the downstream process sensor takes the true position, less suitable when the motor itself is the only position reference. Detent torque is 9.19 N.m, meaning the gearhead holds position back-driven up to that figure with power off — useful for vertical or biased loads where creep would drift the output. Bearing service life is split: 2500 hours short-term operation, 15000 hours long-term. Pick the duty profile against the expected hours-per-shift, not against an L10 marketing number. ## Mechanical envelope and the panel hole you cut Overall length is 174 mm with a 66 mm flange and a 4 mm centring collar depth — that's the back-plate pattern you build the bracket around. Flange mounting is the supported configuration; the body length plus the keyed output shaft set the minimum clearance behind any obstruction. ## Standards, environment, and where it legally goes Marked CE and built to EN/IEC 61800-3 (the drive EMC standard), EN/IEC 50178 (power converter safety), EN 50347 (motor dimensions), and IEC 60072-1 — second-environment EMC category per the 2001 edition, meaning industrial-area use without special mitigation. Shock resistance is 150 m/s² for 1000 shocks and vibration 20 m/s² from 10 to 500 Hz over 10 cycles, both to the EN/IEC 60068-2 series — heavy enough for most process skids and many mobile-platform fits. ## Sourcing reality for the line-down RFQ No official successor or cross-reference is on the record for this order code — the BOM line is its own line, and a board-spin to a different package is the only escape route if supply tightens.","metaTitle":"Schneider Electric ILE2P661PB1A4 servo motor, 12 N.m","metaDescription":"Schneider Electric Lexium ILE integrated drive, 12 N.m nominal, 115:1 gearhead, 66 mm flange, 24/48 VDC.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Servo Motors"],"specifications":{"title":"ILE2P661PB1A4","Length":"174 mm","Marking":"CE","Key width":"16 mm","Shaft end":"Keyed","Standards":"EN/IEC 61800-3 IEC 60072-1 IEC 61800-3, Ed 2 EN 61800-3 : 2001-02 EN 50347 EN 61800-3:2001, second environment EN/IEC 50178","Motor type":"Brushless DC motor","description":"brushless dc motor 24..48 V - Ethernet Powerlink interface - L = 174 mm - 115:1","Network type":"DC","Second shaft":"Without second shaft end","Shaft length":"25 mm","Winding type":"Medium speed of rotation and medium torque","Detent torque":"9.19 N.m","Feedback type":"BLDC encoder","Gear box type":"Straight teeth gear, 4 stages","Holding brake":"Without","Nominal speed":"35 rpm at 24 V 44 rpm at 48 V","Rotor inertia":"1962 kg.cm²","Accuracy error":"+/- 0.5 point","Nominal torque":"12 N.m at 24 V 12 N.m at 48 V","Shaft diameter":"10 mm","Protection type":"Short circuit of the output voltage Overload of output voltage Safe torque off","Reduction ratio":"115:1 (3675:32)","Type of cooling":"Natural convection","lifecycle_stage":"current","Mounting support":"Flange","Range of product":"Lexium integrated drive","Shock resistance":"150 m/s² 1000 shocks conforming to EN/IEC 60068-2-29","Device short name":"ILE","Input/output type":"4 signals (each be used as input or output)","Motor flange size":"66 mm","Peak stall torque":"24.72 N.m at 24 V 24.72 N.m at 48 V","Relative humidity":"15...85 % without condensation","Transmission rate":"100 Mbits","Operating altitude":"<= 1000 m without derating","Current consumption":"7000 mA peak 5500 mA maximum continuous","Nominal output power":"54 W at 24 V 68 W at 48 V","Vibration resistance":"20 m/s² (f= 10...500 Hz) 10 cycles conforming to EN/IEC 60068-2-6","Centring collar depth":"4 mm","Electrical connection":"Printed circuit board connector","Number of motor poles":"6","Service life in hours":"2500 h bearing short-term operation 15000 h bearing long-term operation","Supply voltage limits":"18...55.2 V","Associated fuse rating":"16 A","Discrete input current":"10 mA at 24 V on/STO_A for safety input 3 mA at 24 V on/STO_B for safety input 2 mA at 24 V for 24 V signal interface","Maximum axial force Fa":"10 N (long-term operation) 80 N (short-term operation)","Maximum supply current":"0.1 A (power stage disabled) 6.8 A at 24 V 3.8 A at 48 V","Number of motor stacks":"1","Commissioning interface":"RS485 Modbus TCP (9.6, 19.2 and 38.4 kbauds)","Communication interface":"Ethernet Powerlink, integrated","Continuous stall torque":"14 N.m","Discrete output voltage":"23...25 V","IP degree of protection":"IP41 shaft bushing: conforming to EN/IEC 60034-5 IP54 total except shaft bushing: conforming to EN/IEC 60034-5","Maximum radial force Fr":"200 N (long-term operation) 200 N (short-term operation)","Mounting holes diameter":"4.4 mm","Centring collar diameter":"16 mm","Maximum mechanical speed":"44 rpm","Network number of phases":"Single phase","Number of mounting holes":"4","Maximum switching current":"100 mA per output 200 mA total","Product or component type":"Motion integrated drive","Speed feedback resolution":"12 points/turn motor 0.26° gearbox output","[Us] rated supply voltage":"48 V 24 V","Maximum torsional backlash":"1 °","Voltage state 0 guaranteed":"-3...4.5 V","Voltage state 1 guaranteed":"15...30 V","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"40...55 °C (with power derating of 2 % per °C) 0...40 °C (without derating)","Circle diameter of the mounting holes":"73.54 mm","Permissible ambient air temperature around the device":"105 °C power amplifier 110 °C motor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7bbd22282d5b8f4a78bffb443ac71b01.pdf","sourceUrl":"https://www.se.com/be/en/product/ILE2P661PB1A4/brushless-dc-motor-24-48-v-ethernet-powerlink-interface-l-174-mm-1151/"},"ai":{"faq":[{"question":"Is ILE2P661PB1A4 available via RFQ confirmation and what is the lead time?","answer":"No stock count or ship date is asserted here."},{"question":"What compliance documentation ships with ILE2P661PB1A4?","answer":"The part is CE marked and built to EN/IEC 61800-3 (drive EMC), EN/IEC 50178 (power-converter safety), EN 50347 (motor dimensions), and IEC 60072-1. That is the standards set on the device record itself — RoHS, REACH, and UL file documentation should be requested through the RFQ channel against the specific lot."},{"question":"What is the listed length and flange size of ILE2P661PB1A4?","answer":"Overall length is 174 mm with a 66 mm motor flange and a 4 mm centring collar depth — the back-plate pattern the bracket or panel cut-out has to be built around."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ILE2P661PB1A4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ILE2P661PB1A4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}