{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ILE2P661PB1A5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ILE2P661PB1A5","canonicalUrl":"https://aoctrl.com/schneider/ILE2P661PB1A5","factsUrl":"https://aoctrl.com/api/mcp/products/ILE2P661PB1A5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Lexium ILE integrated drive, ILE2P661PB1A5, brushless DC worm-gear servo, 24/48 V, 3.8 N·m nominal, 66 mm flange, CE marked.","salesMarkdown":"## What the geared head delivers versus a bare BLDC The ILE2P661PB1A5 is a Schneider Electric Lexium ILE integrated drive — a brushless DC motor with an on-board worm-gear reduction of 24:1 (525:22), so the controller, encoder feedback, and mechanical output live in one 229 mm-long, 66 mm flange package rather than the separate motor-plus-gearhead-plus-drive stack that a conventional servo build demands. Because the gearbox is internal, the 168 rpm nominal shaft speed at 24 V and 48 V already reflects the reduction — the buyer sizes against output rpm, not motor rpm, and the 33.6 lbf.in (3.8 N·m) nominal torque at both voltages is what reaches the load. ## Electrical envelope and the 24/48 V decision Supply limits span 18...55.2 V, so the same winding is driven from either a 24 V or 48 VDC bus; nominal torque of 33.6 lbf.in (3.8 N·m) and nominal output power of 45 W at 24 V versus 66 W at 48 V tell the integrator that stepping up the bus roughly lifts continuous mechanical power without changing the torque figure. Current draw peaks at 7000 mA with a 5500 mA continuous ceiling, so the upstream 24/48 V supply needs to budget that transient without tripping — natural-convection cooling means no fan is present and the 66 W continuous rating assumes an ambient that lets the housing shed heat without derating. Peak stall torque of 54.79 lbf.in (6.19 N·m) at both voltages defines the worst-case mechanical load the gearbox and shaft must absorb without slipping past the detent torque floor of 25.7 lbf.in (2.9 N·m). ## Feedback, I/O, and the integrated protection set A BLDC encoder on the motor side feeds back position with ±1 point accuracy, and four signals on the I/O connector can each be used as input or output — that configurability replaces the dedicated direction-enable-fault triad a discrete drive would expose. Built-in protection covers short circuit of the output voltage, safe torque off, and overload of output voltage, which is the standard STO-plus-output-guard package for an integrated drive at this class — the wiring diagram and STO wiring are the spec items to confirm before commissioning. Connection is through a printed circuit board connector rather than a flying lead, so panel builders plan for a mating header on the host PCB and route the 24/48 V bus and I/O signals to that footprint. ## Mechanical fit, environment, and compliance Flange mounting on a 66 mm motor flange with a hole-type shaft end and no second shaft gives a clean bolt-on install — the 9.02 in (229 mm) length is the dimension that drives the cabinet depth and the clearance behind the driven load. Vibration resistance of 20 m/s² over 10...500 Hz and shock resistance of 150 m/s² for 1000 shocks put the unit inside the EN/IEC 60068-2 envelope — adequate for general industrial mounting, though not for a high-shock mobile platform without further qualification. Operating altitude is rated up to 3280.84 ft (1000 m) without derating and humidity sits at 15...85 % non-condensing, while the CE mark is backed by the EN/IEC 61800-3, EN/IEC 50178, EN 50347, and IEC 60072-1 standards family — the EMC and dimensional baselines a European integrator expects for an integrated drive.","metaTitle":"Schneider Electric ILE2P661PB1A5 Servo Motor, 24/48 V","metaDescription":"Schneider Electric Lexium ILE integrated drive, 24/48 V brushless DC geared servo, 3.8 N·m nominal, CE marked, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Servo Motors"],"specifications":{"Phase":"Single phase","Length":"9.02 in (229 mm)","Marking":"CE","Category":"18288 - LEXIUM INTEGRATED DRIVES II","Shaft end":"Hole","Standards":"EN/IEC 61800-3 EN/IEC 50178 IEC 61800-3, Ed 2 EN 50347 EN 61800-3 : 2001-02 EN 61800-3:2001, second environment IEC 60072-1","Motor Type":"Brushless DC motor","Network type":"DC","Second shaft":"Without second shaft end","Winding type":"Medium speed of rotation and medium torque","Detent torque":"25.7 lbf.in (2.9 N.m)","Feedback type":"BLDC encoder","Gear box type":"Worm gear, 2 stages","Holding brake":"Without","Nominal speed":"168 rpm 24 V 168 rpm 48 V","Rotor inertia":"90 kg.cm²","Accuracy error":"+/- 1 point","Nominal torque":"33.6 lbf.in (3.8 N.m) 24 V 33.6 lbf.in (3.8 N.m) 48 V","Protection Type":"Short circuit of the output voltage Safe torque off Overload of output voltage","Reduction ratio":"24:1 (525:22)","Type of cooling":"Natural convection","lifecycle_stage":"current","Mounting Support":"Flange","Range of Product":"Lexium integrated drive","Shock resistance":"150 m/s² 1000 shocks EN/IEC 60068-2-29","Device short name":"ILE","Input/output type":"4 signals (each be used as input or output)","Motor flange size":"2.6 in (66 mm)","Peak stall torque":"54.79 lbf.in (6.19 N.m) 24 V 54.79 lbf.in (6.19 N.m) 48 V","Relative humidity":"15...85 % without condensation","Transmission Rate":"100 Mbits","Operating altitude":"<= 3280.84 ft (1000 m) without derating","Current consumption":"7000 mA peak 5500 mA maximum continuous","Nominal output power":"45 W 24 V 66 W 48 V","Vibration resistance":"20 m/s² 10...500 Hz) 10 cycles EN/IEC 60068-2-6","Electrical Connection":"Printed circuit board connector","Nbr. of units in pkg.":"1","Number of motor poles":"6","Service life in hours":"3000 h bearing","Supply voltage limits":"18...55.2 V","Associated fuse rating":"16 A","Discrete input current":"10 mA at 24 V on/STO_A safety input 3 mA at 24 V on/STO_B safety input 2 mA at 24 V 24 V signal interface","Maximum axial force Fa":"80 N","Maximum supply current":"0.1 A power stage disabled) 6.8 A 24 V 3.8 A 48 V","Number of motor stacks":"1","Commissioning interface":"RS485 Modbus TCP 9.6, 19.2 and 38.4 kbauds)","Communication interface":"Ethernet Powerlink, Integrated","Continuous stall torque":"37.2 lbf.in (4.2 N.m)","Discrete output voltage":"23...25 V","IP degree of protection":"IP41 shaft bushing: conforming to EN/IEC 60034-5 IP54 total except shaft bushing: conforming to EN/IEC 60034-5","Maximum radial force Fr":"200 N","Mounting holes diameter":"0.2 in (4.4 mm)","Centring collar diameter":"1.4 in (36 mm)","Maximum mechanical speed":"186 rpm","Number of mounting holes":"2","Maximum switching current":"100 mA per output 200 mA total","Product or Component Type":"Motion integrated drive","Speed feedback resolution":"12 points/turn motor 1.26° gearbox output","[Us] rated supply voltage":"24 V 48 V","Voltage state 0 guaranteed":"-3...4.5 V","Voltage state 1 guaranteed":"15...30 V","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Ambient air temperature for operation":"104...131 °F (40...55 °C) (with power derating of 2 % per °C) 32...104 °F (0...40 °C) (without derating)","Permissible ambient air temperature around the device":"221 °F (105 °C) power amplifier 230 °F (110 °C) motor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0e8a05efd4485dfb5ddeecdce0f64dda.pdf","sourceUrl":"https://www.se.com/vn/en/product/ILE2P661PB1A5/brushless-dc-motor-24-48-v-ethernet-powerlink-interface-l-174-mm-241/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ILE2P661PB1A5/alternatives.json"},"ai":{"faq":[{"question":"What supply voltage does the ILE2P661PB1A5 run from, and what torque does it deliver?","answer":"Supply limits are 18...55.2 V, so the same unit runs on a 24 V or 48 VDC bus. Nominal torque is 33.6 lbf.in (3.8 N·m) at either voltage, with peak stall torque of 54.79 lbf.in (6.19 N·m) and a 168 rpm nominal speed after the 24:1 gear reduction."},{"question":"What compliance documentation is on file for the ILE2P661PB1A5?","answer":"CE marking is declared and the unit is built to EN/IEC 61800-3, EN/IEC 50178, EN 50347, and IEC 60072-1. That covers the EMC, safety, and dimensional standards a European panel builder expects for an integrated drive in this class."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ILE2P661PB1A5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ILE2P661PB1A5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}