{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ILE2P661PB1A6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ILE2P661PB1A6","canonicalUrl":"https://aoctrl.com/schneider/ILE2P661PB1A6","factsUrl":"https://aoctrl.com/api/mcp/products/ILE2P661PB1A6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Lexium ILE integrated drive ILE2P661PB1A6, brushless DC motor, 6 N.m nominal torque, 75 rpm, 18–55.2 V DC, 66 mm flange, 229 mm length.","salesMarkdown":"## Production status leads — what the lifecycle signal means The ILE2P661PB1A6: Marking CE and the IEC 61800-3 / EN 50178 / EN/IEC 60068 standard stack carry through to the ILE short-name series, so the unit slots into second-environment panels on a normal industrial grounding scheme without a separate filter budget on the design review. ## Mechanical envelope — flange, shaft, worm gear reduction Flange mounting on a 66 mm flange face, 229 mm overall length, with a hole-type shaft end and no second shaft — the kind of body that drops onto an existing bracket when the original actuator geometry is held, so a like-for-like swap rarely forces new machining. Internal worm gear, 3 stages, 54:1 ratio (1715:32) paired with medium speed and medium torque winding — the gearhead absorbs the back-driving load on vertical axes without slipping, and the reduction lets the motor spin where it wants to rather than where the load wants to. ## Torque, speed, current — sizing the BOM line to the load 75 rpm nominal at 24 V and again at 48 V (the drive is happy on either rail across the 18–55.2 V supply window), 6 N.m nominal torque on both rails, and 13.93 N.m peak stall torque on both rails — meaning the steady-state work envelope is the same regardless of which DC bus the cabinet already carries, and headroom for acceleration transients is roughly 2.3× nominal. Sustained draw up to 5500 mA continuous and 7000 mA peak, with 45 W at 24 V and 47 W at 48 V nominal output — so power-supply sizing on a 48 V rail lands near 5.5 A continuous plus margin for the inrush that the 7000 mA peak rating implies. ## Protection, signals, and the cabinet-side wiring Built-in protection covers output voltage overload, output short circuit, and safe torque off (STO) — the STO path is the one the safety circuit lands on, so the ILE can sit inside a category-3 stop without an external contactor on the motor leads. Four signals, each usable as input or output, land on a printed circuit board connector — the PCB connector style and the bidirectional I/O count are what determine the cabinet-side harness, and the cable is keyed to the Lexium ILE pin map rather than a generic servo header. Natural convection cooling, shock at 150 m/s², vibration at 20 m/s² across 10–500 Hz, 15–85 % non-condensing humidity, and 1000 m altitude without derating — meaning the drive goes onto an unenclosed machine frame when the surrounding cabinet is omitted, and it still survives near the motor on a vibrating conveyor truss. Six-pole brushless DC motor with a BLDC encoder feedback path and a bearing life of 6000 h — the service-life figure is the MRO planner's replace-on-failure window when the gearbox sees continuous duty, not a maintenance interval the plant can skip.","metaTitle":"Schneider ILE2P661PB1A6 Lexium Integrated Drive, 6 N.m","metaDescription":"Schneider ILE2P661PB1A6 Lexium integrated drive: 6 N.m nominal, 13.93 N.m peak, 75 rpm, 18–55.2 V DC. Lifecycle current, quoted to order against the BOM line.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Servo Motors"],"specifications":{"Phase":"Single phase","title":"ILE2P661PB1A6","Length":"9.02 in (229 mm)","Marking":"CE","Category":"18288 - LEXIUM INTEGRATED DRIVES II","Shaft end":"Hole","Standards":"IEC 61800-3, Ed 2 EN 61800-3:2001, second environment IEC 60072-1 EN 50347 EN/IEC 50178 EN 61800-3 : 2001-02 EN/IEC 61800-3","Motor Type":"Brushless DC motor","description":"brushless dc motor 24..48 V - Ethernet Powerlink interface - L = 174 mm - 54:1","Network type":"DC","Second shaft":"Without second shaft end","Winding type":"Medium speed of rotation and medium torque","Detent torque":"57.5 lbf.in (6.5 N.m)","Feedback type":"BLDC encoder","Gear box type":"Worm gear, 3 stages","Holding brake":"Without","Nominal speed":"75 rpm 24 V 75 rpm 48 V","Rotor inertia":"430 kg.cm²","Accuracy error":"+/- 1 point","Nominal torque":"53.1 lbf.in (6 N.m) 24 V 53.1 lbf.in (6 N.m) 48 V","Protection Type":"Overload of output voltage Short circuit of the output voltage Safe torque off","Reduction ratio":"54:1 (1715:32)","Type of cooling":"Natural convection","lifecycle_stage":"current","Mounting Support":"Flange","Range of Product":"Lexium integrated drive","Shock resistance":"150 m/s² 1000 shocks EN/IEC 60068-2-29","Device short name":"ILE","Input/output type":"4 signals (each be used as input or output)","Motor flange size":"2.6 in (66 mm)","Peak stall torque":"123.29 lbf.in (13.93 N.m) 24 V 123.29 lbf.in (13.93 N.m) 48 V","Relative humidity":"15...85 % without condensation","Transmission Rate":"100 Mbits","Operating altitude":"<= 3280.84 ft (1000 m) without derating","Current consumption":"7000 mA peak 5500 mA maximum continuous","Nominal output power":"45 W 24 V 47 W 48 V","Vibration resistance":"20 m/s² 10...500 Hz) 10 cycles EN/IEC 60068-2-6","Electrical Connection":"Printed circuit board connector","Nbr. of units in pkg.":"1","Number of motor poles":"6","Service life in hours":"6000 h bearing","Supply voltage limits":"18...55.2 V","Associated fuse rating":"16 A","Discrete input current":"10 mA at 24 V on/STO_A safety input 3 mA at 24 V on/STO_B safety input 2 mA at 24 V 24 V signal interface","Maximum axial force Fa":"80 N","Maximum supply current":"0.1 A power stage disabled) 6.8 A 24 V 2.7 A 48 V","Number of motor stacks":"1","Commissioning interface":"RS485 Modbus TCP 9.6, 19.2 and 38.4 kbauds)","Communication interface":"Ethernet Powerlink, Integrated","Continuous stall torque":"70.8 lbf.in (8 N.m)","Discrete output voltage":"23...25 V","IP degree of protection":"IP41 shaft bushing: conforming to EN/IEC 60034-5 IP54 total except shaft bushing: conforming to EN/IEC 60034-5","Maximum radial force Fr":"200 N","Mounting holes diameter":"0.2 in (4.4 mm)","Centring collar diameter":"1.4 in (36 mm)","Maximum mechanical speed":"93 rpm","Number of mounting holes":"2","Maximum switching current":"100 mA per output 200 mA total","Product or Component Type":"Motion integrated drive","Speed feedback resolution":"12 points/turn motor 0.56° gearbox output","[Us] rated supply voltage":"48 V 24 V","Voltage state 0 guaranteed":"-3...4.5 V","Voltage state 1 guaranteed":"15...30 V","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Ambient air temperature for operation":"104...131 °F (40...55 °C) (with power derating of 2 % per °C) 32...104 °F (0...40 °C) (without derating)","Permissible ambient air temperature around the device":"221 °F (105 °C) power amplifier 230 °F (110 °C) motor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6399df9ec6ece26d6331758791aeb8c1.pdf","sourceUrl":"https://www.se.com/be/en/product/ILE2P661PB1A6/brushless-dc-motor-24-48-v-ethernet-powerlink-interface-l-174-mm-541/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for ILE2P661PB1A6?","answer":"Pricing and stock position for ILE2P661PB1A6 are confirmed at quote time rather than carried as on-page numbers. Submit the BOM quantity against an RFQ and the part will be priced and allocated from independent distribution with full traceability on the build date and lot."},{"question":"What compliance documentation does Schneider Electric provide for ILE2P661PB1A6?","answer":"CE marking is recorded in the spec set, along with the IEC 61800-3 (second environment), EN 50178, EN/IEC 60068 vibration and shock, and IEC 60072-1 / EN 50347 dimension standards — the documentation bundle that ships from Schneider covers these declarations of conformity. Reach out via the RFQ channel for the specific certificate PDFs (DoC, material compliance) tied to the production lot."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ILE2P661PB1A6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ILE2P661PB1A6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}