{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ILE2P661PC1A2","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ILE2P661PC1A2","canonicalUrl":"https://aoctrl.com/schneider/ILE2P661PC1A2","factsUrl":"https://aoctrl.com/api/mcp/products/ILE2P661PC1A2","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Lexium ILE integrated drive, BLDC servo with 38:1 straight-tooth gearbox, 7.3 N·m nominal / 13.07 N·m peak stall, 66 mm flange, keyed 10 mm shaft, 48 V DC nominal.","salesMarkdown":"## Active in the ILE line — quoted against the BOM The ILE2P661PC1A2 sits inside Schneider Electric's Lexium ILE integrated-drive family, where the controller, comms stage and brushless servo motor share one housing — useful when the cabinet side loses an enclosure slot but still has to drive a real load. A first fit-check against an existing axis: the unit is flange-mount on a 66 mm motor flange with a 10 mm keyed shaft and a 25 mm shaft length, so it drops into a standard ILE cutout without re-machining the mounting plate. ## Mechanical envelope — 38:1 gear, 7.3 N·m nominal The gearbox is a 3-stage straight-tooth set with a 38:1 reduction (75:2 form), so the input speed the drive sees is roughly 38× higher than the output shaft — at the rated 107 rpm at 24 V / 133 rpm at 48 V the motor stage is rotating around 4,000–5,000 rpm before the gear train. For a retrofit that means the existing 38:1 coupling, sprocket or belt ratio carries straight across. Torque staged correctly matters more than the headline number: continuous nominal torque is 7.3 N·m at both 24 V and 48 V, and the peak stall is 13.07 N·m at either supply rail — the limiting figure for sizing is peak stall torque, because that is the ceiling the application sees on accel/decel events, not the steady-state rating. Output power at the nominal point is 95 W at 24 V and 119 W at 48 V — running the unit at the higher rail shifts output up by about 25 % at no change in torque, which is the cleanest upgrade path on a 24 V cabinet that can accept a 48 V bus. ## Drive stage — 48 V DC, 4 digital I/O, RS-485 The drive side is a single-phase DC bus, drawing 5,500 mA maximum continuous and 7,000 mA peak at the input — the cabinet PSU must be sized to the peak, not continuous, or the drive will trip on inrush. Braking is regenerative into the DC bus because the unit ships without a holding brake and has no second shaft end — for a vertical axis the customer-side mechanical brake is non-negotiable, but the ILE itself remains compact. Comms link runs through an industrial connector at 100 Mbit/s, with four software-configurable signals on the I/O block — enough for two limit switches, enable, and a status output without needing a remote I/O slice. Protective behaviour is the usual Lexium triad: output over-voltage, safe torque off, and output short-circuit — STO is the relevant one when this unit lands in a machine guarding circuit, and the safety chain should be wired directly to the STO inputs rather than rely on enable over comms. ## Siting envelope — cabinet, altitude, vibration Length overall is 174 mm with a 4 mm centring collar, so any retrofit drawing that shows the standard ILE envelope will accept this code without bracket rework. Environmental envelope: 15...85 % relative humidity non-condensing, operating altitude under 1000 m without derating, shock resistance 150 m/s² and vibration 20 m/s² across 10...500 Hz — it sits happily inside a typical panel-builder enclosure and on a machine frame that sees modest reciprocating duty. ## Compliance — EN/IEC 61800-3, CE marked Compliance is built into the datasheet envelope: EN/IEC 61800-3 (second environment), EN/IEC 50178, EN 50347, IEC 60072-1, and CE marking — the drive-side emissions class follows the second-environment EMC profile, which is the industrial-factory assumption rather than light-commercial.","metaTitle":"Schneider Electric ILE2P661PC1A2 Lexium Servo, 7.3 N·m, 38:1","metaDescription":"Schneider ILE2P661PC1A2 Lexium integrated drive servo, 48 V, 7.3 N·m nominal, 38:1 gear, 66 mm flange. Active line. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Servo Motors"],"specifications":{"Phase":"Single phase","Length":"6.9 in (174 mm)","Marking":"CE","Category":"18288 - LEXIUM INTEGRATED DRIVES II","Key width":"0.6 in (16 mm)","Shaft end":"Keyed","Standards":"EN 50347 EN/IEC 61800-3 IEC 61800-3, Ed 2 EN 61800-3:2001, second environment EN/IEC 50178 IEC 60072-1 EN 61800-3 : 2001-02","Motor Type":"Brushless DC motor","Network type":"DC","Second shaft":"Without second shaft end","Shaft length":"1.0 in (25 mm)","Winding type":"Medium speed of rotation and medium torque","Detent torque":"26.6 lbf.in (3 N.m)","Feedback type":"BLDC encoder","Gear box type":"Straight teeth gear, 3 stages","Holding brake":"Without","Nominal speed":"107 rpm 24 V 133 rpm 48 V","Rotor inertia":"211 kg.cm²","Accuracy error":"+/- 0.5 point","Nominal torque":"64.6 lbf.in (7.3 N.m) 24 V 64.6 lbf.in (7.3 N.m) 48 V","Shaft diameter":"0.4 in (10 mm)","Protection Type":"Overload of output voltage Safe torque off Short circuit of the output voltage","Reduction ratio":"38:1 (75:2)","Type of cooling":"Natural convection","lifecycle_stage":"current","Mounting Support":"Flange","Range of Product":"Lexium integrated drive","Shock resistance":"150 m/s² 1000 shocks EN/IEC 60068-2-29","Device short name":"ILE","Input/output type":"4 signals (each be used as input or output)","Motor flange size":"2.6 in (66 mm)","Peak stall torque":"115.68 lbf.in (13.07 N.m) 24 V 115.68 lbf.in (13.07 N.m) 48 V","Relative humidity":"15...85 % without condensation","Transmission Rate":"100 Mbits","Operating altitude":"<= 3280.84 ft (1000 m) without derating","Current consumption":"7000 mA peak 5500 mA maximum continuous","Nominal output power":"119 W 48 V 95 W 24 V","Vibration resistance":"20 m/s² 10...500 Hz) 10 cycles EN/IEC 60068-2-6","Centring collar depth":"0.2 in (4 mm)","Electrical Connection":"Industrial connector","Nbr. of units in pkg.":"1","Number of motor poles":"6","Service life in hours":"2500 h bearing short-term operation 15000 h bearing long-term operation","Supply voltage limits":"18...55.2 V","Associated fuse rating":"16 A","Discrete input current":"10 mA at 24 V on/STO_A safety input 3 mA at 24 V on/STO_B safety input 2 mA at 24 V 24 V signal interface","Maximum axial force Fa":"10 N long-term operation) 80 N short-term operation)","Maximum supply current":"0.1 A power stage disabled) 6.8 A 24 V 3.8 A 48 V","Number of motor stacks":"1","Commissioning interface":"RS485 Modbus TCP 9.6, 19.2 and 38.4 kbauds)","Communication interface":"Ethernet Powerlink, Integrated","Continuous stall torque":"73.5 lbf.in (8.3 N.m)","Discrete output voltage":"23...25 V","IP degree of protection":"IP41 shaft bushing: conforming to EN/IEC 60034-5 IP54 total except shaft bushing: conforming to EN/IEC 60034-5","Maximum radial force Fr":"200 N long-term operation) 200 N short-term operation)","Mounting holes diameter":"0.2 in (4.4 mm)","Centring collar diameter":"0.6 in (16 mm)","Maximum mechanical speed":"133 rpm","Number of mounting holes":"4","Maximum switching current":"100 mA per output 200 mA total","Product or Component Type":"Motion integrated drive","Speed feedback resolution":"12 points/turn motor 0.8° gearbox output","[Us] rated supply voltage":"48 V 24 V","Maximum torsional backlash":"1 °","Voltage state 0 guaranteed":"-3...4.5 V","Voltage state 1 guaranteed":"15...30 V","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Ambient air temperature for operation":"104...131 °F (40...55 °C) (with power derating of 2 % per °C) 32...104 °F (0...40 °C) (without derating)","Circle diameter of the mounting holes":"2.90 in (73.54 mm)","Permissible ambient air temperature around the device":"221 °F (105 °C) power amplifier 230 °F (110 °C) motor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a0b59645a7de5794ed4242263397cfdb.pdf","sourceUrl":"https://www.se.com/vn/en/product/ILE2P661PC1A2/brushless-dc-motor-24-48-v-ethernet-powerlink-interface-l-174-mm-381/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ILE2P661PC1A2/alternatives.json"},"ai":{"faq":[{"question":"What is the listed phase on ILE2P661PC1A2?","answer":"Single phase on the supply side, with a DC network type feeding the drive bus — the typical cable gland work is a single-phase 24 V or 48 V feed, not a three-phase run."},{"question":"How long is ILE2P661PC1A2 and what shaft does it carry?","answer":"Length overall is 6.9 in (174 mm), shaft diameter 0.4 in (10 mm), shaft length 1.0 in (25 mm), keyed with a 0.6 in (16 mm) key — a standard NEMA-style metric keyed drop-in for the ILE family cutout."},{"question":"What compliance documentation ships with ILE2P661PC1A2?","answer":"The part is CE marked to the declared standards: EN/IEC 61800-3 (second environment), EN/IEC 50178, EN 50347, and IEC 60072-1. The Declaration of Conformity and the relevant test reports cover the EMC second-environment profile only; a residential or light-industrial site would need additional filtering."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ILE2P661PC1A2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ILE2P661PC1A2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}