{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ILE2P661PC1A8","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ILE2P661PC1A8","canonicalUrl":"https://aoctrl.com/schneider/ILE2P661PC1A8","factsUrl":"https://aoctrl.com/api/mcp/products/ILE2P661PC1A8","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric, Lexium integrated drive, brushless DC motor with 3-stage worm gear, ILE2P661PC1A8, 115:1 reduction, 35 rpm nominal, 10.6 N.m nominal torque, 24-48 V DC.","salesMarkdown":"## What ILE2P661PC1A8 actually is The ILE2P661PC1A8 is a Lexium integrated drive — a brushless DC motor, an encoder, and a 3-stage worm gearbox in a single flange-mounted body, with the drive electronics tucked inside the housing. Network type is DC, so the unit is powered directly from a DC bus rather than a mains rectifier stage, and it accepts a supply range of 18 to 55.2 V. It is part of the ILE family from Schneider Electric, designed for low-speed, high-torque positioning where an external gearbox would otherwise sit on the motor shaft. ## Output envelope at the working shaft Nominal speed is 35 rpm at both 24 V and 48 V — a slow-output profile that suits indexing tables, diverters, and valve actuators rather than spindle duty. Nominal torque is 10.6 N.m (93.8 lbf.in) on either supply rail, and peak stall torque reaches 24.72 N.m (218.79 lbf.in), giving roughly 2.3× headroom for acceleration bursts before the overload protection clamps output voltage. Continuous output power is 37 W at 24 V and 39 W at 48 V — small but appropriate for the gearbox reduction and the slow shaft. ## Electrical interface and protection Peak current draw is 7 A and maximum continuous is 5.5 A, so the upstream 24 V or 48 V supply needs headroom above that — the supply limits of 18 to 55.2 V bracket both common DC bus levels. An industrial connector handles field wiring, and four signals can each be configured as input or output, giving the integrator a small I/O budget for end-of-travel sensors, brake release, or fault lines without adding a remote module. Protection covers overload of output voltage, short circuit of the output voltage, and Safe Torque Off — STO matters for guarding: it removes drive power to the motor without removing logic power, which is the standard pattern for category-1 stops on this class of integrated drive. ## Mechanical envelope and environment Body length is 9.02 in (229 mm) on a 66 mm motor flange, flange-mounted with a hole-style shaft end — the through-hole accepts a customer pin or linkage rather than a keyed shaft. Cooling is natural convection, so the drive must be mounted on a surface that can reject heat without forced airflow. Shock resistance is 150 m/s² for 1000 shocks and vibration resistance is 20 m/s² from 10 to 500 Hz over 10 cycles, both per EN/IEC 60068-2 — adequate for industrial cabinet mounting and most conveyor-side installations. ## Compliance and standards The unit carries the CE marking and is designed against EN 50347 (small-power motor frame standardisation), EN/IEC 50178 (power electronics for power installations), and the EN 61800-3 / IEC 61800-3 Ed 2 family for adjustable-speed drives, second environment. Second environment in this context means industrial sites with their own dedicated transformer — the drive assumes the supply has the higher impedance typical of an industrial LV network, and the EMC filtering inside is sized accordingly. Standards coverage is what a control panel builder needs to drop the ILE into a CE-marked machine without re-engineering the emissions story.","metaTitle":"Schneider Electric ILE2P661PC1A8 Lexium Integrated Drive","metaDescription":"Schneider Electric ILE2P661PC1A8 Lexium integrated BLDC drive with 115:1 worm gearbox, 35 rpm, 10.6 N·m nominal torque. CE marked, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Servo Motors"],"specifications":{"Phase":"Single phase","Length":"9.02 in (229 mm)","Marking":"CE","Category":"18288 - LEXIUM INTEGRATED DRIVES II","Shaft end":"Hole","Standards":"EN 50347 EN/IEC 50178 EN/IEC 61800-3 EN 61800-3:2001, second environment EN 61800-3 : 2001-02 IEC 61800-3, Ed 2 IEC 60072-1","Motor Type":"Brushless DC motor","Network type":"DC","Second shaft":"Without second shaft end","Winding type":"Medium speed of rotation and medium torque","Detent torque":"147.8 lbf.in (16.7 N.m)","Feedback type":"BLDC encoder","Gear box type":"Worm gear, 3 stages","Holding brake":"Without","Nominal speed":"35 rpm 24 V 35 rpm 48 V","Rotor inertia":"1980 kg.cm²","Accuracy error":"+/- 1 point","Nominal torque":"93.8 lbf.in (10.6 N.m) 24 V 93.8 lbf.in (10.6 N.m) 48 V","Protection Type":"Overload of output voltage Safe torque off Short circuit of the output voltage","Reduction ratio":"115:1 (3675:32)","Type of cooling":"Natural convection","lifecycle_stage":"current","Mounting Support":"Flange","Range of Product":"Lexium integrated drive","Shock resistance":"150 m/s² 1000 shocks EN/IEC 60068-2-29","Device short name":"ILE","Input/output type":"4 signals (each be used as input or output)","Motor flange size":"2.6 in (66 mm)","Peak stall torque":"218.79 lbf.in (24.72 N.m) 24 V 218.79 lbf.in (24.72 N.m) 48 V","Relative humidity":"15...85 % without condensation","Transmission Rate":"100 Mbits","Operating altitude":"<= 3280.84 ft (1000 m) without derating","Current consumption":"7000 mA peak 5500 mA maximum continuous","Nominal output power":"37 W 24 V 39 W 48 V","Vibration resistance":"20 m/s² 10...500 Hz) 10 cycles EN/IEC 60068-2-6","Electrical Connection":"Industrial connector","Nbr. of units in pkg.":"1","Number of motor poles":"6","Service life in hours":"9000 h bearing","Supply voltage limits":"18...55.2 V","Associated fuse rating":"16 A","Discrete input current":"10 mA at 24 V on/STO_A safety input 3 mA at 24 V on/STO_B safety input 2 mA at 24 V 24 V signal interface","Maximum axial force Fa":"80 N","Maximum supply current":"0.1 A power stage disabled) 6.8 A 24 V 2.9 A 48 V","Number of motor stacks":"1","Commissioning interface":"RS485 Modbus TCP 9.6, 19.2 and 38.4 kbauds)","Communication interface":"Ethernet Powerlink, Integrated","Continuous stall torque":"123.9 lbf.in (14 N.m)","Discrete output voltage":"23...25 V","IP degree of protection":"IP41 shaft bushing: conforming to EN/IEC 60034-5 IP54 total except shaft bushing: conforming to EN/IEC 60034-5","Maximum radial force Fr":"200 N","Mounting holes diameter":"0.2 in (4.4 mm)","Centring collar diameter":"1.4 in (36 mm)","Maximum mechanical speed":"44 rpm","Number of mounting holes":"2","Maximum switching current":"100 mA per output 200 mA total","Product or Component Type":"Motion integrated drive","Speed feedback resolution":"12 points/turn motor 0.26° gearbox output","[Us] rated supply voltage":"24 V 48 V","Voltage state 0 guaranteed":"-3...4.5 V","Voltage state 1 guaranteed":"15...30 V","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Ambient air temperature for operation":"104...131 °F (40...55 °C) (with power derating of 2 % per °C) 32...104 °F (0...40 °C) (without derating)","Permissible ambient air temperature around the device":"221 °F (105 °C) power amplifier 230 °F (110 °C) motor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b5377b3054b1b8dcd5c742b57601fd5a.pdf","sourceUrl":"https://www.se.com/vn/en/product/ILE2P661PC1A8/brushless-dc-motor-24-48-v-ethernet-powerlink-interface-l-174-mm-1151/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ILE2P661PC1A8/alternatives.json"},"ai":{"faq":[{"question":"What is the listed phase of ILE2P661PC1A8 on this servo line?","answer":"Phase is listed as single phase, with the drive itself running from a DC bus in the 18 to 55.2 V range. The 'single phase' designation reflects the drive-side classification rather than the supply wiring — the unit takes DC, not AC mains."},{"question":"What compliance documentation does Schneider Electric provide for ILE2P661PC1A8?","answer":"The unit carries CE marking and is designed against EN 50347, EN/IEC 50178, EN/IEC 61800-3, EN 61800-3:2001 second environment, IEC 61800-3 Ed 2, and IEC 60072-1. Specific RoHS, REACH, and UL file documentation is not listed on this seed record and would be supplied per RFQ against the project compliance pack."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ILE2P661PC1A8","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ILE2P661PC1A8 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}