{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ILS1B851PB1F0","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ILS1B851PB1F0","canonicalUrl":"https://aoctrl.com/schneider/ILS1B851PB1F0","factsUrl":"https://aoctrl.com/api/mcp/products/ILS1B851PB1F0","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric, Lexium integrated drive series, ILS stepper drive, ILS1B851PB1F0, 85 mm flange, 6 N·m holding brake, 24/36 VDC.","salesMarkdown":"## What the ILS1B851PB1F0 actually drives The ILS1B851PB1F0 sits inside Schneider's Lexium integrated drive (ILS) family, combining a 3-phase stepper motor with on-board drive electronics so a single module carries both the power stage and the motion controller. It is wired through a printed circuit board connector and uses four signals configurable as inputs or outputs for end-of-travel limits, enable, fault, or pulse direction depending on the host controller. Power enters as a DC bus on a single-phase architecture; the part carries CE marking and is designed to EN/IEC 61800-3 (second environment) plus EN/IEC 50178, which is the industrial drive EMC and insulation book. Practically, that means the module is meant to live inside a machine cabinet, not on the open factory floor, and it should be grounded through the PCB connector shield path the way the integration manual specifies. ## Torque, speed, and the holding brake The integrated holding brake pulls in with 22 W and releases in 40 ms; with a 6 N·m holding figure the brake is sized for the same shaft load the motor produces, so axis sizing is a single envelope rather than a motor-plus-brake pair. Index-pulse feedback gives homing accuracy to ±6 arc minutes, which is the figure that matters when this drive is paired against a reference mark in a registration cut. ## Safety functions and EMC envelope Current consumption is capped at 5000 mA maximum and cooling is by natural convection only, so the cabinet layout must keep the surrounding free-air space the integration manual calls out. Mechanical environment is rated to EN/IEC 60068-2-6 vibration (20 m/s² across 10–500 Hz for 10 cycles) and 60068-2-29 shock (150 m/s² for 1000 shocks), with 15–85% non-condensing humidity and 1000 m altitude without derating — a typical indoor panel envelope, not a washdown or outdoor deployment. ## Mechanical fit into the machine frame The 85 mm flange is the standard NEMA 23-class footprint for this class of integrated drive, with a 7.4 in (187.3 mm) body length, 12 mm shaft diameter, 30 mm shaft length, and untapped shaft end. Centring collar depth is 0.08 in (2 mm) — the small clearance that drives whether a customer can reuse an existing mounting plate or needs a new adapter. There is no gearbox, no second shaft end, and no integrated gear option on this code. Communications ride on a multi-drop RS-485-style link supporting 9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, and 12000 kbauds; that ladder is the Lexium ILS default, and the right rate is whichever matches the host motion controller's bus cycle — not the highest number on the list. ## Sourcing posture for the BOM line CE compliance and the EN/IEC 61800-3 (second environment) conformance are the approvals a European machine builder will ask for at the declaration of conformity step.","metaTitle":"Schneider Electric ILS1B851PB1F0 Servo Drive, 6 N·m, 24/36 V","metaDescription":"Schneider Electric Lexium ILS1B851PB1F0 integrated stepper drive: 85 mm flange, 6 N·m holding brake torque, 24/36 VDC, CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Length":"7.4 in (187.3 mm)","Current":"5000 mA maximum","Motor Type":"3-phase stepper motor","Feedback Type":"Index pulse","Product Status":"Active","Shaft Diameter":"0.5 in (12 mm)","Shaft End Type":"Untapped","Temp Storage Max":"70 °C","Temp Storage Min":"-25 °C","Temp Operating Max":"65 °C","Temp Operating Min":"50 °C","Temperature Storage":"-13...158 °F (-25...70 °C)","Max Axial Force Fa N":"170 N tensile force) 30 N force pressure)","Max Radial Force Fr N":"100 N","Centring Collar Diameter":"2.4 in (60 mm)","Main Product Or Component Type":"Motion integrated drive","Permissible Ambient Air Temperature Around The Device":"221 °F (105 °C) power amplifier 230 °F (110 °C) motor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c0a6160c17d9eb8416cc67d90424f974.pdf","sourceUrl":"https://www.se.com/vn/en/product/ILS1B851PB1F0/integrated-drive-ils-with-stepper-motor-24-36-v-profibus-dp-5-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ILS1B851PB1F0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ILS1B851PB1F0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ILS1B851PB1F0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}