{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"K8DT-LS1CA","brand":"Omron","brandSlug":"omron","productSlug":"K8DT-LS1CA","canonicalUrl":"https://aoctrl.com/omron/K8DT-LS1CA","factsUrl":"https://aoctrl.com/api/mcp/products/K8DT-LS1CA","rawCanonicalId":null},"summary":{"shortDescription":"Omron K8DT series, constant level controller, order code K8DT-LS1CA, 100-240VAC supply, SPDT relay output 5A@250VAC, sensitivity 10-100kOhm, DIN rail mount, spring terminal.","salesMarkdown":"## What the K8DT-LS1CA does on a line The Omron K8DT-LS1CA is a constant level controller — it monitors liquid level via a conductive probe and switches a relay when the level crosses the set point. The sensitivity adjustment (10 to 100 kOhm) lets you tune the detection threshold for different liquid conductivity, from distilled water to conductive process fluids. Runs on 100-240VAC supply, so it fits standard panel power without a separate transformer. The SPDT relay contacts are rated 5A at 250VAC — enough to drive a small pump or alarm directly. ## Mounting and wiring reality The 100m max distance between controller and sensor means the probe can sit at the far end of a tank or sump. Built-in delay timer filters out surface slosh or turbulence — the relay doesn't chatter on every wave.","metaTitle":"Omron K8DT-LS1CA Constant Level Controller, 100-240VAC, SPDT","metaDescription":"Omron K8DT-LS1CA constant level controller, 100-240VAC supply, sensitivity 10-100kOhm, SPDT relay output 5A@250VAC. Active production, DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Process / Temperature Controllers"],"specifications":{"Type":"Constant Level","title":"K8DT-LS1CA","Series":"K8DT","Weight":"0.221 lb (100.24 g)","Package":"Box","Features":"Delay Timer","Output Type":"Relay","Sensitivity":"10 ~ 100kOhm","description":"CONTROL LIQ LEV 100-240VAC DIN","Contact Form":"SPDT (1 Form C)","Mounting Type":"DIN Rail","lifecycle_stage":"current","Voltage - Supply":"100 ~ 240VAC","Termination Style":"Spring Terminal","Operating Temperature":"-20°C~60°C","Contact Rating @ Voltage":"5A @ 250VAC","Distance - Control To Sensor (Max)":"100m"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null},"ai":{"faq":[{"question":"What is the sensitivity setting range for the Omron K8DT-LS1CA?","answer":"The sensitivity is adjustable from 10 to 100 kOhm, which lets you match the probe circuit to the conductivity of the liquid being monitored."},{"question":"What supply voltage does the K8DT-LS1CA require?","answer":"It operates on 100-240VAC, so it connects directly to standard line voltage without an external power supply."},{"question":"Is the K8DT-LS1CA a direct replacement for the K8DT-LS1?","answer":"The evidence does not list a direct-replacement relationship between the K8DT-LS1CA and the K8DT-LS1. Confirm the wiring and sensitivity range against your existing unit before swapping."},{"question":"What is the contact rating and form of the K8DT-LS1CA?","answer":"The output is a SPDT (1 Form C) relay rated 5A at 250VAC."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/omron/K8DT-LS1CA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/K8DT-LS1CA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}