{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LA9G4712","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LA9G4712","canonicalUrl":"https://aoctrl.com/schneider/LA9G4712","factsUrl":"https://aoctrl.com/api/mcp/products/LA9G4712","rawCanonicalId":null},"summary":{"shortDescription":"Schneider LA9G4712 Spreader, set of 4, width 2.2 in (55 mm), depth 3.3 in (85 mm).","salesMarkdown":"This is a Schneider LA9G4712 Spreader — a terminal extension accessory that fits under a 4-pole contactor or busbar to spread the line terminals into parallel connection points. Supplied as a set of four identical pieces. Complies with EN/IEC 60947-1, UL 60947-1, CSA C22.2 No 60947-1, and GB/T 14048. Each spreader measures 3.3 in (85 mm) deep, 2.2 in (55 mm) wide, 0.2 in (6 mm) high. The 4P designation means one spreader handles one pole; order one set per 4-pole device. ## Lifecycle and availability Listed as current production — this is a standard catalogue accessory from Schneider. No end-of-life notice applies.","metaTitle":"Schneider LA9G4712 Spreader Set, Active","metaDescription":"Active Schneider LA9G4712 terminal extension spreader in set of 4. Rated pollution degree 3, compliant EN/IEC/UL. Sourced to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"3.3 in (85 mm)","Width":"2.2 in (55 mm)","Height":"0.2 in (6 mm)","Category":"US10I1222328","Standards":"EN/IEC 60947-1 UL 60947-1 CSA C22.2 No 60947-1 GB/T 14048","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"Set of 4","Device short name":"LA9G","Poles description":"4P","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Nbr. of units in pkg.":"1","Product or Component Type":"Spreader","Accessory / separate part category":"Connection accessories"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$273.46","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bea84030deba43a6ac1151eae7e7e3fc.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LA9G4712/alternatives.json"},"ai":{"faq":[{"question":"What compliance standards does LA9G4712 meet?","answer":"Compliant with EN/IEC 60947-1, UL 60947-1, CSA C22.2 No 60947-1, and GB/T 14048. Pollution degree 3 per IEC 60947-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LA9G4712","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LA9G4712 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}