{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LA9GRD01","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LA9GRD01","canonicalUrl":"https://aoctrl.com/schneider/LA9GRD01","factsUrl":"https://aoctrl.com/api/mcp/products/LA9GRD01","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Function Module LA9GRD01, 1 NC auxiliary contact, 5 A conventional free air thermal current, IP20, 50 mm depth.","salesMarkdown":"The Schneider LA9GRD01 is a function module that sits on top of a TeSys contactor and gives you a remote alarm signal through a single dry NC contact. That NC contact is rated for the 5 A free-air thermal current, so it can drive a relay or a PLC input directly—but watch the load curve on inductive coils. IP20 keeps dust off the terminals, though I still blow out the panel annually.","metaTitle":"Schneider LA9GRD01 TeSys Function Module, 5A NC Contact, IP2","metaDescription":"Active Schneider LA9GRD01 function module for TeSys contactor range. 1 NC auxiliary, 5A thermal current, IP20, meets EN/IEC/UL standards. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"2.0 in (50 mm)","Range":"TeSys","Width":"1.2 in (30 mm)","Height":"3.6 in (91.5 mm)","Category":"US10I1222328","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ","lifecycle_stage":"current","Connection pitch":"0.20 in (5.08 mm)","Pollution degree":"3 IEC 60947-1","Quantity per Set":"Set of 1","Device short name":"LA9G","Mounting Location":"Top","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Nbr. of units in pkg.":"1","IP degree of protection":"IP20 conforming to IEC 60529","Main Function Available":"Remote alarm","Product or Component Type":"Function module","Auxiliary contact composition":"1 NC","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Ith] conventional free air thermal current":"5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$169.84","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bea84030deba43a6ac1151eae7e7e3fc.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LA9GRD01/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this module carry?","answer":"It meets EN/IEC 60947-4-1 and -5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, JIS C8201-4-1 and -5-1, plus IEC 60335-1 and -2-40 annex JJ for appliance safety."},{"question":"What are the key electrical ratings?","answer":"One NC auxiliary contact rated 5 A conventional free-air thermal current. The contact is rated per the IEC/UL standards above, so you can switch pilot-duty loads without concern."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LA9GRD01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LA9GRD01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}