{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LAD8N026","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LAD8N026","canonicalUrl":"https://aoctrl.com/schneider/LAD8N026","factsUrl":"https://aoctrl.com/api/mcp/products/LAD8N026","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca auxiliary contact block, LAD8N026, 2NC contacts, side-mount, lugs-ring terminals, 10 A Ith, 690 V insulation.","salesMarkdown":"The LAD8N026 is a TeSys Deca auxiliary contact block — two normally-closed (2NC) contacts that mount on the side of a contactor or starter. It's the kind of part you grab when you need a spare NC feedback loop for a safety circuit or a status signal back to the PLC, and you need it to fit the existing TeSys Deca footprint without reworking the panel. Rated 10 A conventional free-air thermal current (Ith) at 60 °C, with an insulation voltage (Ui) of 690 V per IEC 60947-5-1 and 600 V per UL/CSA. That means it handles the control-circuit loads you'd expect — pilot duty, relay coils, contactor pick-up — without derating surprises in a warm enclosure. The NC contacts are mechanically linked with a 1.5 ms non-overlap time on both energisation and de-energisation — no momentary bridging between NC and NO circuits. That matters for safety interlocks where you need a guaranteed break before the make. Rated operational current (Ie) varies by duty: 6 A at 120 V AC-15 (typical for solenoid valves and contactor coils), 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13. The AC-15 rating is the one you'll lean on for most control-circuit switching — it's the standard for electromagnetic loads. The DC-13 numbers are lower because DC arcs are harder to extinguish; if you're switching DC relay coils at 125 V, the 0.55 A limit governs. Making capacity is 140 A AC and 250 A DC per IEC 60947-5-1 — that's the peak inrush the contacts can close onto without welding. Short-time ratings (100 A for 1 s, 120 A for 500 ms, 140 A for 100 ms) cover brief overloads like capacitor bank or lamp inrush. Minimum switching capability is 5 mA at 17 V — so it'll reliably switch dry contacts or low-level PLC inputs without needing a wetting current. That's a detail that trips people up on cheaper blocks. Side-mounts onto TeSys Deca contactors and reversing starters. Occupies a 12.5 mm wide slot — that's one module width on a DIN-rail assembly, so it doesn't eat up panel space. Depth is 71.3 mm, height 72 mm; stays within the envelope of the base contactor. Terminals accept lugs-ring connections with an 8 mm outer diameter. Tightening torque is 1.7 N·m with a flathead, Philips #2, or Pozidriv #2 — any electrician's screwdriver will do. No special tools. IP20 finger-safe protection per IEC 60529 — fine for enclosed panels. Standards compliance covers EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, plus IEC 60335-1 Clause 30.2 and UL 60335-2-40 Annex JJ for appliance applications. That's the full set for industrial control panels and HVAC equipment destined for North America or Europe. Mechanical durability is 30 million cycles — essentially lifetime for a control-circuit contact block in normal service. No wear-item replacement schedule needed.","metaTitle":"Schneider TeSys Deca LAD8N026 Auxiliary Contact Block, 2NC,","metaDescription":"LAD8N026 TeSys Deca auxiliary contact block, 2NC, side mount, lugs-ring terminals. Rated 10 A Ith, 690 V insulation. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"71.3 mm","Width":"12.5 mm","Height":"72 mm","Current":"6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13","Voltage":"690 V AC 25...400 Hz","IP Rating":"IP20","Product Status":"Active","Protection Type":"GG fuse 10 A","Temp Storage Max":"80 °C","Temp Storage Min":"-60 °C","Temp Operating Max":"60 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-60...80 °C","Mechanical Life Cycles":"30 Mcycles","Main Product Or Component Type":"Auxiliary contact block","Ambient Air Temperature Operation":"-5...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2cc1a14c17db69a1d82e579503e91426.pdf","sourceUrl":"https://www.se.com/hk/en/product/LAD8N026/auxiliary-contact-block-tesys-deca-2nc-side-mounting-lugsring-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LAD8N026/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LAD8N026","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LAD8N026 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}