{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LADN116G","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LADN116G","canonicalUrl":"https://aoctrl.com/schneider/LADN116G","factsUrl":"https://aoctrl.com/api/mcp/products/LADN116G","rawCanonicalId":null},"summary":{"shortDescription":"Auxiliary contact block, TeSys Deca, 1NO + 1NC, front mounting, lugs-ring terminals, EN 50012","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"42 mm","Range":"TeSys","Width":"26 mm","Height":"48 mm","Product name":"TeSys Deca","Protection type":"GG fuse 10 A","lifecycle_stage":"current","Non-overlap time":"1.5 ms on de-energisation no overlap between NC and NO contact 1.5 ms on energisation no overlap between NC and NO contact","Device short name":"LADN","Mounting location":"Front","Tightening torque":"1.7 N.m - with screwdriver flat Ø 6 mm M3.5 1.7 N.m - with screwdriver Philips No 2 M3.5 1.7 N.m - with screwdriver pozidriv No 2 M3.5","Contacts operation":"Instantaneous","Operating altitude":"3000 m","Protective treatment":"TH conforming to IEC 60068","Insulation resistance":"> 10 MOhm","Mechanical durability":"30 Mcycles","Connections - terminals":"Lugs-ring terminals (external diameter: 8 mm)","IP degree of protection":"IP20 conforming to IEC 60529","Pole contact composition":"1 NO + 1 NC","Minimum switching current":"5 mA","Minimum switching voltage":"17 V","Product or component type":"Auxiliary contact block","Irms rated making capacity":"140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1","Environmental characteristic":"Normal environment","Permissible short-time rating":"100 A 60 °C 1 s 120 A 60 °C 500 ms 140 A 60 °C 100 ms","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-5-1 600 V conforming to UL 60947-5-1 600 V conforming to CSA C22.2 No 60947-5-1","[Ie] rated operational current":"6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13","[Ue] rated operational voltage":"690 V AC 25...400 Hz","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...60 °C","[Ith] conventional free air thermal current":"10 A (at 60 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5a253b05e89e8ca52bd311cfa5486dde.pdf","sourceUrl":"https://www.se.com/nz/en/product/LADN116G/auxiliary-contact-block-tesys-deca-1no-+-1nc-front-mounting-lugsring-terminals-en-50012/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LADN116G/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LADN116G","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LADN116G when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}