{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LADN226PJ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LADN226PJ","canonicalUrl":"https://aoctrl.com/schneider/LADN226PJ","factsUrl":"https://aoctrl.com/api/mcp/products/LADN226PJ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LADN226PJ auxiliary contact block, 2NO + 2NC, front mounting, lugs-ring terminals, EN 50012.","salesMarkdown":"It provides 2 normally open and 2 normally closed instantaneous contacts, wired via lugs-ring terminals. This block signals the contactor's position back to the control system — telling a PLC or relay logic that the main contacts have picked up or dropped out. Rated operational current is 6 A at 690 V in AC-15 duty (solenoid/contactor coil loads), and 1.04 A at 125 V DC-13 (DC solenoid loads). The conventional free-air thermal current is 10 A at 60 °C. Minimum switching is 5 mA at 17 V — important for low-energy PLC inputs that might not wet a dry contact. Making capacity is 140 A AC and 250 A DC per IEC 60947-5-1, so it can handle inrush from a pilot device without welding. This auxiliary block mounts on the front of a TeSys Deca contactor, adding status feedback for motor starters, pump panels, conveyor controls, and compressor skids. The IP20 finger-safe housing suits enclosed panel installation. The TH protective treatment per IEC 60068 means it's rated for tropical/humid environments — a plus for Gulf Coast or Southeast Asian plants. ## Installation notes Mounts on the front of the contactor — no DIN rail needed. Terminals accept lugs-ring terminals with 8 mm outer diameter. Tightening torque is 1.7 N·m with a flat, Philips #2, or Pozidriv #2 screwdriver. Altitude rated to 3000 m. ## Protection and approvals Protected by a 10 A GG fuse. Insulation resistance exceeds 10 MOhm. Rated for short-time currents: 100 A for 1 second, 120 A for 500 ms, 140 A for 100 ms at 60 °C. Approvals include IEC 60947-5-1, UL 60947-5-1, and CSA C22.2 No. 60947-5-1 for the insulation voltage ratings.","metaTitle":"Schneider LADN226PJ TeSys Deca Auxiliary Contact Block, 2NO+","metaDescription":"Schneider Electric LADN226PJ auxiliary contact block for TeSys Deca contactors. 2NO+2NC, front mount, lugs-ring terminals. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"42 mm","Width":"44 mm","Height":"48 mm","Current":"6 A at 690 V AC-15 1.04 A at 125 V DC-13 0.55 A at 600 V DC-13 0.1 A","Voltage":"690 V AC 25...400 Hz","IP Rating":"IP20","Product Status":"Active","Protection Type":"GG fuse 10 A","Temp Storage Max":"80 °C","Temp Storage Min":"-60 °C","Insulation Voltage Ui":"690 V conforming to IEC 60947-5-1 600 V conforming to UL 60947-5-1 600 V conforming to CSA C22.2 No 60947-5-1","Temp Operating Max":"60 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-60...80 °C","Mechanical Life Cycles":"30 Mcycles","Main Product Or Component Type":"Auxiliary contact block","Ambient Air Temperature Operation":"-5...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e2c4a8b9202a491e709e67d9deaef9f9.pdf","sourceUrl":"https://www.se.com/sg/en/product/LADN226PJ/auxiliary-contact-block-tesys-deca-2no-+-2nc-front-mounting-lugsring-terminals-en-50012/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LADN226PJ/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LADN226PJ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LADN226PJ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}