{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LADR09","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LADR09","canonicalUrl":"https://aoctrl.com/schneider/LADR09","factsUrl":"https://aoctrl.com/api/mcp/products/LADR09","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LADR09, off-delay time delay auxiliary contact block, 1NO+1NC, 0.3-3 s range, front mount, Faston terminals, IP20.","salesMarkdown":"## Product Description and Key Ratings The LADR09 is an off-delay time delay auxiliary contact block from the TeSys Deca range, configured as 1 normally open plus 1 normally closed contact. The time delay range is 0.3 to 3 seconds, set via an external adjustment on the front face. It mounts on the front of a TeSys Deca contactor or reversing starter, occupying the auxiliary slot, and connects via Faston terminals rated for 10 A conventional free air thermal current at 60 °C. Rated operational current per IEC 60947-5-1: 6 A at 120 V AC-15 (pilot duty), 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13. Minimum switching capability is 5 mA at 17 V, which means it can reliably switch low-level PLC inputs and signal-level loads without contact wetting issues. The block carries an IP20 degree of protection per IEC 60529, suitable for installation inside a closed control panel. Mechanical durability is rated at 5 million cycles. ## Integration Notes The block mounts on the front of a TeSys Deca contactor or reversing starter, occupying the auxiliary contact slot. Faston terminals (0.25 in / 6.35 mm) accept standard spade connectors; strip length and crimp tool selection follow the manufacturer's wiring recommendations for 0.75 to 2.5 mm² stranded wire. The off-delay function starts when the contactor coil is de-energised; the timing period runs from the instant of coil drop-out. The permissible short-time rating allows 100 A for 1 second, 120 A for 500 ms, and 140 A for 100 ms at 60 °C — relevant for inrush loads like solenoid valves or small motor starters.","metaTitle":"TeSys Deca LADR09 Off-Delay Timer Block, 0.3-3s, 1NO+1NC","metaDescription":"Obsolete TeSys Deca LADR09 off-delay auxiliary contact block. 0.3-3s range, 1NO+1NC, Faston terminals, IP20. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"2.4 in (61 mm)","Width":"1.7 in (44 mm)","Height":"1.9 in (48 mm)","Current":"6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13","Voltage":"690 V AC 25...400 Hz","IP Rating":"IP20","Timer Type":"Off delay","Product Status":"Active","Protection Type":"GG fuse 10 A","Temp Storage Max":"80 °C","Temp Storage Min":"-60 °C","Time Delay Range":"0.3–3 s","Insulation Voltage Ui":"690 V IEC 60947-5-1 600 V UL 60947-5-1 600 V CSA C22.2 No 60947-5-1","Temp Operating Max":"70 °C","Temp Operating Min":"-40 °C","Temperature Storage":"-76...176 °F (-60...80 °C)","Mechanical Life Cycles":"5 Mcycles","Ambient Air Temperature Operation":"-40...158 °F (-40...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dc292c6fd292a2f38001d85254f21ed5.pdf","sourceUrl":"https://www.se.com/th/en/product/LADR09/time-delay-auxiliary-contact-block-tesys-deca-1no-+-1nc-off-delay-0-33s-front-faston-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LADR09/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LADR09","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LADR09 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}