{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LADT23","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LADT23","canonicalUrl":"https://aoctrl.com/schneider/LADT23","factsUrl":"https://aoctrl.com/api/mcp/products/LADT23","rawCanonicalId":null},"summary":{"shortDescription":"SQD LADT23 CONTACTOR TIME DEL|SQD LADT23 CONTACTOR TIME DEL","salesMarkdown":null,"metaTitle":"LADT23","metaDescription":"SQD LADT23 CONTACTOR TIME DEL|SQD LADT23 CONTACTOR TIME DEL","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"2.4 in (61 mm)","Range":"TeSys TeSys Deca","Width":"1.7 in (44 mm)","Height":"1.9 in (48 mm)","Category":"US10I1222341","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ","Timer type":"On delay","Product name":"TeSys Deca","Protection type":"GG fuse 10 A","lifecycle_stage":"current","Non-overlap time":"1.5 ms on de-energisation no overlap between NC and NO contact 1.5 ms on energisation no overlap between NC and NO contact","Time delay range":"1...30 s","Mounting Location":"Front","Contacts operation":"Time delay","Operating altitude":"9842.52 ft (3000 m)","Protective treatment":"TH IEC 60068","Insulation resistance":"> 10 MOhm","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Connections - terminals":"spring terminals 2 0.004 in² (2.5 mm²)flexible without cable end spring terminals 2 0.004 in² (2.5 mm²)rigid","IP degree of protection":"IP2X conforming to IEC 60529","Pole contact composition":"1 NO + 1 NC","Minimum switching current":"5 mA","Minimum switching voltage":"17 V","Product or Component Type":"Time delay auxiliary contact block","Irms rated making capacity":"140 A AC 250 A DC","Environmental characteristic":"Normal environment","Permissible short-time rating":"100 A 140 °F (60 °C) 1 s 120 A 140 °F (60 °C) 500 ms 140 A 140 °F (60 °C) 100 ms","[Ui] rated insulation voltage":"690 V IEC 60947-5-1 600 V UL 600 V CSA","[Ie] rated operational current":"6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13","[Ue] rated operational voltage":"690 V AC 25...400 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-40...158 °F (-40...70 °C)","[Ith] conventional free air thermal current":"10 A (at 140 °F (60 °C))"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$30.48","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/24b7802fbc825d715e1c7a1faec35f6b.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LADT23/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LADT23","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LADT23 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}