{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LAEX3F7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LAEX3F7","canonicalUrl":"https://aoctrl.com/schneider/LAEX3F7","factsUrl":"https://aoctrl.com/api/mcp/products/LAEX3F7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LAEX3F7 contactor coil, 110 V AC 50/60 Hz, 34.4 Ohm at 20 °C.","salesMarkdown":"## Coil for LC1E40–65 contactors It runs on a 110 V AC 50/60 Hz control circuit, drawing 160 VA inrush at 50 Hz and 140 VA at 60 Hz (cos φ 0.75, 20 °C). Once sealed, hold-in drops to 15 VA at 50 Hz or 13 VA at 60 Hz — the coil resistance measures 34.4 Ω at 20 °C. The 110 V AC coil is built for standard line-voltage control schemes — common in panel designs where the contactor coil ties directly to a control transformer secondary. The 0.85–1.1 Uc operational range (at <60 °C) means the coil picks up reliably at 93.5 V and drops out above 121 V, so a sagging control bus won't cause chatter. Ambient temperature tops out at 60 °C, which covers most ventilated enclosures but not hot-zone panels near ovens or furnaces.","metaTitle":"Schneider Electric LAEX3F7 Easy TeSys Contactor Coil, 110 V","metaDescription":"Schneider Electric LAEX3F7 replacement coil for LC1E40–65 contactors. 110 V AC 50/60 Hz control circuit, 34.4 Ohm coil resistance. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"Easy TeSys","title":"LAEX3F7","description":"TVS 3P LC1E40~65â€¦ COIL 110V AC 50/60Hz","lifecycle_stage":"current","Range of product":"Easy TeSys Control","Device short name":"LAEX","Average resistance":"34.4 Ohm at 20 °C","Inrush power in VA":"160 VA 50 Hz cos phi 0.75 (at 20 °C) 140 VA 60 Hz cos phi 0.75 (at 20 °C)","Control circuit type":"AC at 50/60 Hz standard","Product or component type":"Contactor coil","Inductance of closed circuit":"1.93 H","[Uc] control circuit voltage":"110 V AC 50/60 Hz","Control circuit voltage limits":"Operational: 0.85...1.1 Uc at 50/60 Hz (at <60 °C)","Hold-in power consumption in VA":"15 VA 50 Hz cos phi 0.3 (at 20 °C) 13 VA 60 Hz cos phi 0.3 (at 20 °C)","Ambient air temperature for operation":"-5...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a671413ea9a726a198b2cfe537ff8e2d.pdf","sourceUrl":"https://www.se.com/in/en/product/LAEX3F7/tvs-3p-lc1e4065â-coil-110v-ac-50-60hz/"},"ai":{"faq":[{"question":"What contactors does the LAEX3F7 fit?","answer":"It is the replacement coil for Schneider LC1E40 through LC1E65 contactors in the Easy TeSys line. The 110 V AC 50/60 Hz coil bolts directly into those frames."},{"question":"What is the inrush and hold-in power?","answer":"Inrush is 160 VA at 50 Hz or 140 VA at 60 Hz (cos φ 0.75, 20 °C). Once the contactor seals, hold-in drops to 15 VA at 50 Hz or 13 VA at 60 Hz."},{"question":"What is the operating temperature range?","answer":"Rated for -5 to 60 °C ambient air temperature during operation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LAEX3F7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LAEX3F7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}