{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1BP33F13","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1BP33F13","canonicalUrl":"https://aoctrl.com/schneider/LC1BP33F13","factsUrl":"https://aoctrl.com/api/mcp/products/LC1BP33F13","rawCanonicalId":null},"summary":{"shortDescription":"bar-mounted contactor - TeSys LC1-BP - 3P - AC-3 1000 V 2000 A - coil 110 VAC","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"31.1 in (790 mm)","Range":"TeSys","Width":"18.7 in (475 mm)","Height":"19.7 in (500 mm)","Category":"18402-WORLD SERVICE PARTS(CONTROL ACCESS)","Coil type":"Standard","Standards":"BS 5424 NF C 63-110 IEC 60158-1 VDE 0660 IEC 60947-4","Product name":"TeSys B","Motor power kW":"425 kW at 220...230 V AC 50/60 Hz 670 kW at 1000 V AC 50/60 Hz 700 kW at 500 V AC 50/60 Hz 750 kW at 380...400 V AC 50/60 Hz 750 kW at 660...690 V AC 50/60 Hz 800 kW at 415 V AC 50/60 Hz 800 kW at 440 V AC 50/60 Hz","Operating time":"100...150 ms closing 20...40 ms opening","lifecycle_stage":"mature","Protective cover":"With","Average impedance":"0.13 mOhm - Ith 2000 A 50 Hz for power circuit","Device short name":"LC1BP","Poles description":"3P","Tightening torque":"Power circuit 309.8 lbf.in (35 N.m) bars","Inrush power in VA":"1300 VA","Operating altitude":"9842.52 ft (3000 m) without derating","Control circuit type":"AC","Protective treatment":"TC TH","Utilisation category":"AC-1 AC-3","Contactor application":"Motor-heating-lighting","Mechanical durability":"1200000 cycles","Nbr. of units in pkg.":"1","Associated fuse rating":"1600 A aM at 2000 A gI at <= 440 V for power circuit","Maximum operating rate":"120 cyc/h 131 °F (55 °C)","Auxiliary contacts type":"Instantaneous 1 NO + 3 NC","Connections - terminals":"Power circuit bars 3 x 100 x 5 mm","Rated breaking capacity":"12000 A at 500 V for power circuit conforming to IEC 60158-1 12000 A at 500 V for power circuit conforming to IEC 60947-4 15000 A at 440 V for power circuit conforming to IEC 60158-1 15000 A at 440 V for power circuit conforming to IEC 60947-4 5000 A at 1000 V for power circuit conforming to IEC 60158-1 5000 A at 1000 V for power circuit conforming to IEC 60947-4 9000 A at 660...690 V for power circuit conforming to IEC 60158-1 9000 A at 660...690 V for power circuit conforming to IEC 60947-4","Pole contact composition":"3 NO","Product or Component Type":"Contactor","Irms rated making capacity":"15000 A at 1000 V AC for power circuit conforming to IEC 60158-1 15000 A at 1000 V AC for power circuit conforming to IEC 60947-4","Power dissipation per pole":"520 W AC-1 - Ith 2000 A","Rated operational power in W":"200 W 500 V AC 1000000 cycles - control circuit 230 W 440 V AC 1000000 cycles - control circuit 250 W 110 V AC 1000000 cycles - control circuit 250 W 220 V AC 1000000 cycles - control circuit","[Uc] control circuit voltage":"110 V AC 50...400 Hz","Auxiliary contact composition":"1 NO + 3 NC","Rated operational power in VA":"2000 VA 110...127 V AC-1 1000000 cycles - control circuit 2000 VA 110...127 V AC-3 1000000 cycles - control circuit 3500 VA 500 V AC-1 1000000 cycles - control circuit 3500 VA 500 V AC-3 1000000 cycles - control circuit 4000 VA 220 V AC-1 1000000 cycles - control circuit 4000 VA 220 V AC-3 1000000 cycles - control circuit 4000 VA 380 V AC-1 1000000 cycles - control circuit 4000 VA 380 V AC-3 1000000 cycles - control circuit 4000 VA 415...440 V AC-1 1000000 cycles - control circuit 4000 VA 415...440 V AC-3 1000000 cycles - control circuit","[Ui] rated insulation voltage":"1000 V - power circuit IEC 60158-1 1000 V - power circuit IEC 60947-4 1500 V - power circuit VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc Drop-out: 0.35...0.5 Uc","[Ie] rated operational current":"2000 A (at 1500 A (at <104 °F (40 °C)) AC AC-3 for power circuit","[Ue] rated operational voltage":"Power circuit <= 1000 V AC 50/60 Hz","Hold-in power consumption in VA":"31 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)","[Ith] conventional free air thermal current":"2000 A (at 104 °F (40 °C)) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/LC1BP33F13/barmounted-contactor-tesys-lc1bp-3p-ac3-1000-v-2000-a-coil-110-vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1BP33F13/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1BP33F13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1BP33F13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}