{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1D09AFE7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1D09AFE7","canonicalUrl":"https://aoctrl.com/schneider/LC1D09AFE7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1D09AFE7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca Advanced contactor, LC1D09AFE7, 3-pole (3NO), AC-3/AC-3e duty to 9 A at ≤440 V, 115 V AC 50/60 Hz coil, snap-in terminals.","salesMarkdown":"## Headline class and duty envelope The Schneider Electric LC1D09AFE7 is a 3-pole contactor in the TeSys Deca Advanced line, listed for motor control and resistive load across AC-1, AC-3, AC-3e, and AC-4 utilisation categories. Its headline rating is 9 A on AC-3/3e at ≤440 V across motor control and resistive load duty, not a heavy-industrial contactor, but a standard pick for compact panels. ## Coil, terminals, and panel-side envelope Footprint is 86 mm deep by 45 mm wide by 107 mm tall, so it shares the LC1D frame footprint and drops into standard TeSys Deca panel layouts without re-cutting the mounting plate or gland plate. Front-face IP20 to IEC 60529 — finger-safe on the operator side once wired, with the usual caveat that the terminations themselves need shrouding for full panel IP. ## Operating envelope and derating Permissible ambient around the device is -40...60 °C, with derating required between 60 and 70 °C; the panel builder needs to size cabinet ventilation against the upper limit, not the headline 40 °C benchmark. Operating altitude is rated 0...3000 m without further compensation — covers the bulk of European and most North American sites, but anything above that needs a derate check. Mechanical robustness is 4 Gn vibration contactor closed (5...300 Hz) and 15 Gn shock closed for 11 ms, so it survives standard machine-mount cabinets and skids without a separate anti-vibration mount. ## Compliance documentation Standards coverage includes EN 60947-4-1, IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, plus IEC 60335-1 Clause 30.2 and the IEC/UL 60335-2-40 Annex JJ clauses. Fire resistance is rated 850 °C to IEC 60695-2-1, and the protective treatment is TH to IEC 60068-2-30 for damp heat; climatic withstand is to IACS and IEC 60947-1 Annex Q category D, which is what the declaration pack cites for marine and offshore exposure.","metaTitle":"Schneider LC1D09AFE7 TeSys Deca Contactor, 3P 9A, 115V coil","metaDescription":"Schneider LC1D09AFE7 TeSys Deca Advanced 3P contactor, AC-3/3e to 9 A, 115 V AC 50/60 Hz coil, snap-in terminals. Specified into the BOM and quoted to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"86 mm","Width":"45 mm","Height":"107 mm","Standards":"EN 60947-4-1 IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"mature","Mounting support":"Plate Rail","Non-overlap time":"1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact","Range of product":"TeSys Deca","Device short name":"LC1D","Poles description":"3P","Climatic withstand":"conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068-2-30","Utilisation category":"AC-1 AC-3 AC-3e AC-4","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor closed (15 Gn for 11 ms) Shocks contactor open (10 Gn for 11 ms)","IP degree of protection":"IP20 front face conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: Power circuit: 10 MOhm for signalling circuit","Permissible ambient air temperature around the device":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$53.95","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9f35515b6c8abc5ce183ad0a7f970960.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC1D09AFE7/contactor-tesys-deca-3p3no-ac3-3e-440v-9a-115v-ac-50-60hz-coil-snapin-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1D09AFE7/alternatives.json"},"ai":{"faq":[{"question":"What is LC1D09AFE7's depth on this TeSys Deca Advanced line?","answer":"Depth is listed as 86 mm, which is the standard LC1D frame depth and drops straight into existing TeSys Deca panel cutouts without rework."},{"question":"What is LC1D09AFE7's width on this TeSys Deca Advanced line?","answer":"Width is 45 mm on the listed spec, matching the single-module LC1D frame that side-by-sides with adjacent TeSys Deca components on the same DIN rail."},{"question":"What compliance documentation does Schneider provide for LC1D09AFE7?","answer":"The standards listing covers EN/IEC/UL/CSA 60947-4-1 plus the IEC/UL 60335-2-40 Annex JJ clauses for HVAC/refrigeration machinery, with 850 °C fire resistance to IEC 60695-2-1 and damp-heat withstand to IACS and IEC 60947-1 Annex Q category D."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1D09AFE7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1D09AFE7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}