{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1D115004F7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1D115004F7","canonicalUrl":"https://aoctrl.com/schneider/LC1D115004F7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1D115004F7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider LC1D115004F7 Tesys Deca Advanced — now discontinued, supplied from remaining surplus and broker stock.","salesMarkdown":"## Overview The LC1D115004F7 is a Schneider TeSys Deca Advanced 4-pole contactor rated for 200 A switching current across AC-1, AC-3, AC-3e, and AC-4 utilization categories, with a 110 V AC 50/60 Hz coil. It carries UL 60947-4-1, CSA C22.2 No 14, IEC 60947-4-1, and EN 60947-4-1 certifications, and is sealed to IP20 with a built-in bidirectional peak limiting diode suppressor on the coil. The 200 A switching current and 1.1 kA breaking capacity (ICU) suit this contactor for resistive loads and motor switching up to 200 A in AC-3 duty; the 1260 A rated making capacity at 440 V handles inrush during motor start.","metaTitle":"Schneider LC1D115004F7 TeSys Deca Advanced contactor, 200 A, 110 V AC coil","metaDescription":"Schneider LC1D115004F7 TeSys Deca Advanced contactor: 200 A switching current, 4 NO poles, 110 V AC 50/60 Hz coil, UL/CSA/IEC certified, IP20.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"5.2 in (132 mm)","Range":"TeSys","Width":"5.9 in (150 mm)","Height":"6.2 in (158 mm)","Category":"US10I1222359","Standards":"CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 60947-4-1","Operating time":"6...20 ms opening 20...50 ms closing","Coil technology":"Built-in bidirectional peak limiting diode suppressor","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"mature","Flame retardance":"V1 conforming to UL 94","Heat dissipation":"3...8 W at 50/60 Hz","Mounting Support":"Plate Rail","Pollution degree":"3","Protective cover":"With","Range of Product":"TeSys Deca","Average impedance":"0.6 mOhm - Ith 200 A 50 Hz for power circuit","Device short name":"LC1D","Poles description":"4P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2","Climatic withstand":"IACS E10 exposure to damp heat IEC 60947-1 Annex Q category D exposure to damp heat","Compatibility code":"LC1D","Inrush power in VA":"280...350 VA 60 Hz cos phi 0.8 (at 68 °F (20 °C)) 280...350 VA 50 Hz cos phi 0.8 (at 68 °F (20 °C))","Operating altitude":"0...9842.52 ft (0...3000 m)","Control circuit type":"AC 50/60 Hz","Overvoltage category":"III","Protective treatment":"THIEC 60068-2-30","Utilisation category":"AC-1 AC-3 AC-3e AC-4","Contactor application":"Resistive load","Electrical durability":"0.8 Mcycles 200 A AC-1 <= 440 V","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations contactor open 2 Gn, 5...300 Hz) Vibrations contactor closed 4 Gn, 5...300 Hz) Shocks contactor closed 15 Gn for 11 ms) Shocks contactor open 6 Gn for 11 ms)","Nbr. of units in pkg.":"1","Associated fuse rating":"250 A gG at 200 A gG at <= 690 V coordination type 2 for power circuit","Maximum operating rate":"2400 cyc/h at 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: solid without cable end Power circuit: connector 1 0.02...0.2 in² (10...120 mm²) - cable stiffness: flexible without cable end Power circuit: connector 2 0.02...0.08 in² (10...50 mm²) - cable stiffness: flexible without cable end Power circuit: connector 1 0.02...0.2 in² (10...120 mm²) - cable stiffness: flexible with cable end Power circuit: connector 2 0.02...0.08 in² (10...50 mm²) - cable stiffness: flexible with cable end Power circuit: connector 1 0.02...0.2 in² (10...120 mm²) - cable stiffness: solid without cable end Power circuit: connector 2 0.02...0.08 in² (10...50 mm²) - cable stiffness: solid without cable end","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"4 NO","Safety reliability level":"B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"1260 A at 440 V for power circuit conforming to IEC 60947","Power dissipation per pole":"24 W AC-1","[Uc] control circuit voltage":"110 V AC 50/60 Hz","[Ui] rated insulation voltage":"Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1","Control circuit voltage limits":"0.3...0.5 Uc (-40...158 °F (-40...70 °C)):drop-out AC 50/60 Hz 0.8...1.15 Uc (-40...131 °F (-40...55 °C)):operational AC 50/60 Hz 1...1.15 Uc (131...158 °F (55...70 °C)):operational AC 50/60 Hz","[Ie] rated operational current":"200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit Power circuit <= 460 V DC","Hold-in power consumption in VA":"2...18 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)) 2...18 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947","[Icw] rated short-time withstand current":"250 A 104 °F (40 °C) - 10 min for power circuit 550 A 104 °F (40 °C) - 1 min for power circuit 950 A 104 °F (40 °C) - 10 s for power circuit 1100 A 104 °F (40 °C) - 1 s for power circuit","[Ith] conventional free air thermal current":"200 A (at 140 °F (60 °C)) for power circuit","Permissible ambient air temperature around the device":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$811.57 – $872.81","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/38e92673e47ecbe511930a6901b5726a.pdf","sourceUrl":"https://www.se.com/eg/en/product/LC1D115004F7/contactor-tesys-deca-4p4no-ac1-440v-200a-110v-ac-50hz-coil-screw-clamp-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1D115004F7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1D115004F7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1D115004F7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}