{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1D400086F7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1D400086F7","canonicalUrl":"https://aoctrl.com/schneider/LC1D400086F7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1D400086F7","rawCanonicalId":null},"summary":{"shortDescription":"TeSys Deca contactor, 4P(2 NO + 2 NC), AC-1 <= 440V, 60 A 110V AC 50/60 Hz coil","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"4.9 in (125 mm)","Range":"TeSys","Width":"3.3 in (85 mm)","Height":"5 in (127 mm)","Category":"US10I1222357","Standards":"CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508","Operating time":"4...19 ms opening 12...26 ms closing","Coil technology":"Without built-in suppressor module","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"mature","Flame retardance":"V1 conforming to UL 94","Heat dissipation":"4...5 W at 50/60 Hz","Mounting Support":"Plate Rail","Pollution degree":"3","Protective cover":"Without","Range of Product":"TeSys Deca","Average impedance":"1.5 mOhm - Ith 60 A 50 Hz for power circuit","Device short name":"LC1D","Poles description":"4P","Tightening torque":"Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 22.1 lbf.in (2.5 N.m) lugs-ring terminals hexagonal 0.4 in (10 mm) M6","Climatic withstand":"IACS E10 exposure to damp heat","Compatibility code":"LC1D","Inrush power in VA":"140 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C)) 160 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))","Operating altitude":"0...9842.52 ft (0...3000 m)","Control circuit type":"AC 50/60 Hz","Overvoltage category":"III","Protective treatment":"THIEC 60068-2-30","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"1.4 Mcycles 60 A AC-1 <= 440 V","Mechanical durability":"6 Mcycles","Mechanical robustness":"Shocks contactor open 8 Gn for 11 ms) Shocks contactor closed 10 Gn for 11 ms) Vibrations contactor opened 2 Gn, 5...300 Hz) Vibrations contactor closed 4 Gn, 5...300 Hz)","Nbr. of units in pkg.":"1","Associated fuse rating":"80 A gG at 80 A gG at <= 690 V coordination type 2 for power circuit","Connections - terminals":"Control circuit: lugs-ring terminals - external diameter: 0.3 in (8 mm) Power circuit: lugs-ring terminals - external diameter: 0.6 in (16.5 mm)","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"800 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"800 A at 440 V for power circuit conforming to IEC 60947","Power dissipation per pole":"5.4 W AC-1","[Uc] control circuit voltage":"110 V AC 50/60 Hz","[Ui] rated insulation voltage":"Power circuit 600 V CSA Power circuit 600 V UL Power circuit 690 V IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-40...158 °F (-40...70 °C)):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40...140 °F (-40...60 °C)):operational AC 50 Hz 0.85...1.1 Uc (-40...140 °F (-40...60 °C)):operational AC 60 Hz 1...1.1 Uc (140...158 °F (60...70 °C)):operational AC 50/60 Hz","[Ie] rated operational current":"60 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit Power circuit <= 300 V DC","Hold-in power consumption in VA":"13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)) 15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947","[Icw] rated short-time withstand current":"320 A 104 °F (40 °C) - 10 s for power circuit 720 A 104 °F (40 °C) - 1 s for power circuit 72 A 104 °F (40 °C) - 10 min for power circuit 165 A 104 °F (40 °C) - 1 min for power circuit","[Ith] conventional free air thermal current":"60 A (at 140 °F (60 °C)) for power circuit","Permissible ambient air temperature around the device":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8527abb05284b5a31d8a152a08a69845.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC1D400086F7/tesys-deca-contactor-4p2-no-+-2-nc-ac1-440v-60-a-110v-ac-50-60-hz-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1D400086F7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1D400086F7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1D400086F7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}