{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1D80008P7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1D80008P7","canonicalUrl":"https://aoctrl.com/schneider/LC1D80008P7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1D80008P7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca contactor, 4-pole, LC1D80008P7, 125 A AC-1 resistive rating, 4P, AC coil 50/60 Hz.","salesMarkdown":"This LC1D80008P7 is a 4-pole TeSys Deca contactor from Schneider Electric, rated 125 A in AC-1 (resistive) duty — that's the utilisation category for resistive loads like heaters or lighting. The control circuit is AC 50/60 Hz, drawing 245 VA at 20 °C during inrush. Mechanical durability is 4 Mcycles, and electrical durability is 0.8 Mcycles at 125 A AC-1 ≤ 440 V. The contactor mounts on either a plate or a rail, and the pole contact composition is 2 NO + 2 NC, giving you normally-open and normally-closed auxiliary contacts built in. Power circuit terminals accept up to 50 mm² flexible cable with a tightening torque of 12 N.m; control circuit terminals use screw clamps at 1.2 N.m. Dimensions: depth 5.5 in (140 mm), width 3.8 in (96 mm), height 5 in (127 mm) — a standard TeSys Deca footprint that fits existing panel layouts. ## Compliance and standards coverage This contactor carries a wide range of certifications: EN 60947-4-1, IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 14, plus IEC 60335-2-40 Annex JJ for heat pump applications. Flame retardance is V1 per UL 94, glow-wire tested at 850 °C. Heat dissipation is 6 to 10 W at 50/60 Hz. The contactor is shipped without a protective cover and without a built-in suppressor module (you'll need to add one externally if the application demands it). Operating time: 20 to 35 ms closing, 6 to 20 ms opening. Climatic withstand IACS, protective treatment TH per IEC 60068-2-30. Rated breaking capacity is 1100 A at 440 V for the power circuit (IEC 60947). Associated fuse rating: 200 A gG or 160 A gG at ≤690 V for type 2 coordination. Maximum operating rate 3600 cycles per hour at 60 °C.","metaTitle":"Schneider LC1D80008P7 TeSys Deca 4P Contactor, AC-1 125A","metaDescription":"Schneider LC1D80008P7 4-pole TeSys Deca contactor, 125A AC-1 resistive load, mature lifecycle, sourced globally. Depth 5.5 in (140 mm). UL, CSA, IEC listed.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"5.5 in (140 mm)","Range":"TeSys","Width":"3.8 in (96 mm)","Height":"5 in (127 mm)","Category":"US10I1222359","Standards":"EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 CSA C22.2 No 14 UL 60947-4-1 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ IEC 60335-1:Clause 30.2","Operating time":"20...35 ms closing 6...20 ms opening","Coil technology":"Without built-in suppressor module","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"mature","Flame retardance":"V1 conforming to UL 94","Heat dissipation":"6...10 W at 50/60 Hz","Mounting Support":"Plate Rail","Pollution degree":"3","Protective cover":"Without","Range of Product":"TeSys Deca","Average impedance":"0.8 mOhm - Ith 125 A 50 Hz for power circuit","Device short name":"LC1D","Poles description":"4P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2","Climatic withstand":"IACS E10 exposure to damp heat","Compatibility code":"LC1D","Inrush power in VA":"245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C)) 245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))","Operating altitude":"0...9842.52 ft (0...3000 m)","Control circuit type":"AC 50/60 Hz","Overvoltage category":"III","Protective treatment":"THIEC 60068-2-30","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"0.8 Mcycles 125 A AC-1 <= 440 V","Mechanical durability":"4 Mcycles","Mechanical robustness":"Vibrations contactor open 2 Gn, 5...300 Hz) Shocks contactor open 8 Gn for 11 ms) Vibrations contactor closed 3 Gn, 5...300 Hz) Shocks contactor closed 10 Gn for 11 ms)","Nbr. of units in pkg.":"1","Associated fuse rating":"200 A gG at 160 A gG at <= 690 V coordination type 2 for power circuit","Maximum operating rate":"3600 cyc/h at 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end Power circuit: connector 1 0.006...0.08 in² (4...50 mm²) - cable stiffness: flexible without cable end Power circuit: connector 2 0.006...0.04 in² (4...25 mm²) - cable stiffness: flexible without cable end Power circuit: connector 1 0.006...0.08 in² (4...50 mm²) - cable stiffness: flexible with cable end Power circuit: connector 2 0.006...0.02 in² (4...16 mm²) - cable stiffness: flexible with cable end Power circuit: connector 1 0.006...0.08 in² (4...50 mm²) - cable stiffness: solid without cable end Power circuit: connector 2 0.006...0.04 in² (4...25 mm²) - cable stiffness: solid without cable end","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Power dissipation per pole":"12.5 W AC-1","[Uc] control circuit voltage":"230 V AC 50/60 Hz","[Ui] rated insulation voltage":"Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1","Control circuit voltage limits":"0.85...1.1 Uc (-40...131 °F (-40...55 °C)):operational AC 60 Hz 0.3...0.6 Uc (-40...131 °F (-40...55 °C)):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40...131 °F (-40...55 °C)):operational AC 50 Hz","[Ie] rated operational current":"125 A (at <140 °F (60 °C)) at <= 1000 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit <= 690 V AC 25...400 Hz","Hold-in power consumption in VA":"26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)) 26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947","[Icw] rated short-time withstand current":"640 A 104 °F (40 °C) - 10 s for power circuit 990 A 104 °F (40 °C) - 1 s for power circuit 135 A 104 °F (40 °C) - 10 min for power circuit 320 A 104 °F (40 °C) - 1 min for power circuit","[Ith] conventional free air thermal current":"125 A (at 140 °F (60 °C)) for power circuit","Permissible ambient air temperature around the device":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$695.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d39aa311f3064a5edf7521c4ad2cadab.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1D80008P7/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of this contactor?","answer":"Depth is 5.5 inches (140 mm)."},{"question":"Which product range does LC1D80008P7 belong to?","answer":"It is part of the TeSys Deca range by Schneider Electric."},{"question":"What compliance documentation does this contactor meet?","answer":"It meets EN 60947-4-1, IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 14, and IEC 60335-2-40 Annex JJ for heat pump applications. Flame retardance is V1 per UL 94."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1D80008P7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1D80008P7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}