{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E06004N5WB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E06004N5WB","canonicalUrl":"https://aoctrl.com/schneider/LC1E06004N5WB","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E06004N5WB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control LC1E06004N5WB, 4-pole contactor, 16 A AC-1 rated operational current, 415 V AC 50 Hz control circuit, screw clamp terminals, IP20.","salesMarkdown":"Its headline rating is 16 A at ≤440 V AC in utilisation category AC-1, which means it handles resistive heater banks, lighting, or transformer loads — not motor starting. The 4 NO (normally open) pole configuration gives you four independent switching paths, all closed when the coil is energised. The control circuit is AC at 50 Hz, wide-range, with a nominal voltage of 415 V AC. Drop-out occurs between 0.3 and 0.6 Uc, and pick-up between 0.7 and 1.25 Uc across the -5 to 55 °C range — so it stays pulled in through moderate sags but drops cleanly when the control signal is removed. Screw-clamp terminals on both power and control circuits accept flexible wire with or without ferrules, 1 to 4 mm² range on most connections, torqued to 1.2 N·m. No auxiliary contacts are built in — if you need N/O or N/C auxiliaries for feedback or interlocking, they must be added as separate side-mount blocks. If your load is a resistive heater bank drawing 12 A, this contactor has headroom. But if you are switching a motor (AC-3 duty), this part is not rated for that — the AC-1 category is strictly resistive. The 48 A rated breaking capacity at 440 V and 60 A making capacity tell you it can interrupt and close onto faults, but the coordination fuse (12 A gG at ≤690 V, type 1) sets the practical short-circuit protection limit. Mechanical durability is listed at 10 million cycles; electrical durability at 150,000 cycles under AC-1. For a resistive load switched once per minute, that electrical life translates to roughly 100 days of continuous 24/7 operation — fine for batch processes, but plan spares for high-duty-cycle applications. Heat dissipation runs 2 to 3 W on the control circuit and 1 W per pole, so panel thermal rise is modest.","metaTitle":"Schneider Electric LC1E06004N5WB Easy TeSys Contactor, 4P, 1","metaDescription":"Schneider Electric LC1E06004N5WB Easy TeSys contactor, 4 NO poles, rated 16 A AC-1 at ≤440 V, 415 VAC 50 Hz coil. Current lifecycle stage. Sourced to order. RFQ for pricing and lea","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"12...22 ms on closing 4...19 ms on opening","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"2...3 W for control circuit","Mounting support":"DIN rail Plate","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"2.5 mOhm - Ith 16 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Power circuit: 1.2 N.m Control circuit: 1.2 N.m","Inrush power in VA":"95 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068-2-30","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"150000 cycles AC-1","Mechanical durability":"10000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","Associated fuse rating":"12 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1800 cyc/h 60 °C","Connections - terminals":"Power circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid","IP degree of protection":"IP20 conforming to IEC 60529","Rated breaking capacity":"48 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"4 NO","Product or component type":"Contactor","Irms rated making capacity":"60 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"1 W AC-1","[Uc] control circuit voltage":"415 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"16 A (at <55 °C) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"8.3 VA 50 Hz cos phi 0.3 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"80 A 40 °C - 10 s for power circuit 45 A 40 °C - 60 s for power circuit 20 A 40 °C - 600 s for power circuit","[Ith] conventional free air thermal current":"16 A (at 55 °C) for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7322f03730e5acd54912b0b9446fb20f.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E06004N5WB/contactoreasy-tesys-controllc1e4p4noac1-16a415v50hz-wide-range/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E06004N5WB/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative in the Easy TeSys family?","answer":"Within the Easy TeSys Control range, the closest peer is the LC1E06004N7WB, which shares the same 4-pole, 16 A AC-1 frame but uses a 24 V AC 50 Hz control coil instead of 415 V AC. The choice between them is driven entirely by your control voltage — the mechanical and power ratings are identical."},{"question":"What compliance documentation is available for this contactor?","answer":"The LC1E06004N5WB is designed to EN/IEC 60947-1, EN/IEC 60947-4-1, and EN/IEC 60947-5-1, plus the Chinese GB/T equivalents. It carries an IP20 protection rating and TH protective treatment per IEC 60068-2-30 for damp-heat environments. Fire resistance is tested to 850 °C per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E06004N5WB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E06004N5WB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}