{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E06008B7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E06008B7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E06008B7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E06008B7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E06008B7IN, 4P (2NO+2NC) contactor, AC-1 ≤415V 20A, 24V coil, DIN rail/plate mount.","salesMarkdown":"The Schneider Electric LC1E06008B7IN is a 4-pole contactor from the Easy TeSys Control range, configured 2NO+2NC, rated 20 A in AC-1 utilisation category at ≤415 V with a 24 V coil. AC-1 covers resistive loads — heaters, lighting banks, non-inductive circuits — so this contactor is not rated for motor starting or inductive switching. Mounts on plate or DIN rail (45 mm width, 74 mm height, 80 mm depth), with IP2X finger protection per IEC 60529. Rated for operation at altitudes up to 3000 m and ambient temperatures from -5 °C to +55 °C, with storage down to -60 °C. Compliant with EN/IEC 60947-1, 60947-4-1, 60947-5-1 and the corresponding GB/T standards, with fire resistance tested to 850 °C per IEC 60695-2-1. Mechanical robustness is specified for vibration (1.5 Gn open, 3 Gn closed) and shock (7 Gn open, 10 Gn closed) — figures that confirm it holds its state under typical industrial floor vibration. ## What the AC-1 rating means for fit The 20 A rating is valid only in AC-1 (resistive) duty. This contactor has no AC-3 or AC-4 motor-rating curve, so it cannot switch induction motors, solenoids, or transformer primaries without severe contact erosion.","metaTitle":"Schneider LC1E06008B7IN Easy TeSys Contactor, 4P 20A AC-1 24","metaDescription":"Obsolete Schneider LC1E06008B7IN Easy TeSys Control contactor. 4P (2NO+2NC), 20A AC-1 at ≤415V, 24V coil. Sourced to order against RFQ. DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/679317d3714d869d093f6cdd385ef649.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E06008B7IN/contactoreasy-tesys-controllc1e4p2no+2ncac1415v20a24v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E06008B7IN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings I need to match for a substitute?","answer":"The critical fit parameters are: 4-pole configuration (2NO+2NC), 20 A continuous rating in AC-1 utilisation category at ≤415 V, 24 V coil voltage, and DIN rail / plate mounting. The 45 mm width and 80 mm depth are the panel-space constraints."},{"question":"What compliance documentation exists for this part?","answer":"The contactor is certified to EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus the corresponding GB/T standards. Fire resistance is tested to 850 °C per IEC 60695-2-1. The protective treatment is TH (pollution degree 3) per IEC 60068. No RoHS, REACH, or UL documentation is listed in the available records."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E06008B7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E06008B7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}