{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E06008M5WBIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E06008M5WBIN","canonicalUrl":"https://aoctrl.com/schneider/LC1E06008M5WBIN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E06008M5WBIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control LC1E06008M5WBIN, 4-pole contactor, 20 A AC-1 at ≤415 V, 220 V AC 50 Hz coil, IP20, DIN rail mount.","salesMarkdown":"The Schneider Electric Easy TeSys LC1E06008M5WBIN is a 4-pole contactor rated for resistive loads under AC-1 utilization category, carrying 20 A at ≤415 V AC. The 220 V AC 50 Hz coil is wide-range AC control. The AC-1 rating means this contactor is designed for switching resistive heater banks, lighting, or other non-inductive loads where the current inrush is minimal. Screw-clamp terminals accept 1 to 6 mm² solid or flexible wire for the power circuit, and 1 to 4 mm² for the control circuit. Torque both circuits to 1.2 N·m. The IP20 finger-safe housing suits enclosed panel installation — not washdown or outdoor service. ## Electrical performance and durability Mechanical durability is 10 million cycles; electrical durability under AC-1 is 150,000 cycles. Coil inrush is 95 VA at 50 Hz, with a hold power dissipation of 2 to 3 W. The contactor opens in 12 to 22 ms and closes in 4 to 19 ms. Protective treatment is TH conforming to IEC 60068 for tropical environments.","metaTitle":"Schneider Easy TeSys LC1E06008M5WBIN Contactor, 20A AC-1, 22","metaDescription":"Schneider Electric Easy TeSys LC1E06008M5WBIN 4-pole contactor, 20A AC-1 resistive load, 220V AC 50Hz coil. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Operating time":"12...22 ms on closing 4...19 ms on opening","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"2...3 W for control circuit","Mounting support":"DIN rail Plate","Pollution degree":"3","Range of product":"Easy TeSys Control","Average impedance":"2.5 mOhm - Ith 20 A 50 Hz for power circuit","Device short name":"LC1E","Poles description":"4P","Tightening torque":"Power circuit: 1.2 N.m Control circuit: 1.2 N.m","Inrush power in VA":"95 VA 50 Hz cos phi 0.75 (at 20 °C)","Operating altitude":"3000 m","Control circuit type":"AC at 50 Hz wide range","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"150000 cycles AC-1","Mechanical durability":"10000000 cycles","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","Associated fuse rating":"12 A gG at <= 690 V coordination type 1 for power circuit","Maximum operating rate":"1800 cyc/h 60 °C","Connections - terminals":"Power circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1...6 mm² - cable stiffness: solid Power circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 1 1...6 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid","IP degree of protection":"IP20 conforming to IEC 60529","Rated breaking capacity":"48 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Product or component type":"Contactor","Irms rated making capacity":"60 A at 440 V AC for power circuit conforming to IEC 60947-4-1","Power dissipation per pole":"1 W AC-1","[Uc] control circuit voltage":"220 V AC 50 Hz","Auxiliary contact composition":"Without","[Ui] rated insulation voltage":"690 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-5...55 °C):drop-out 50 Hz 0.7...1.25 Uc (-5...55 °C):operational 50 Hz","[Ie] rated operational current":"20 A (at <40 °C) at <= 415 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"8.5 VA 50 Hz cos phi 0.3 (at 20 °C)","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"80 A 40 °C - 10 s for power circuit 45 A 40 °C - 60 s for power circuit 20 A 40 °C - 600 s for power circuit","[Ith] conventional free air thermal current":"20 A (at 40 °C) for power circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC1E06008M5WBIN/easy-tesys-contactor-4p-ctr-32a-ac12no+2nc220v-50hz-wb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E06008M5WBIN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of this contactor?","answer":"Rated operational current is 20 A at ≤415 V AC under AC-1 (resistive load). Coil voltage is 220 V AC 50 Hz. It is a 4-pole contactor with 2 NO + 2 NC main poles."},{"question":"What compliance documentation does Schneider provide for this part?","answer":"The part is certified to EN/IEC 60947-1, EN/IEC 60947-4-1, and EN/IEC 60947-5-1. The manufacturer provides a Declaration of Conformity for CE marking and RoHS/REACH compliance documentation on request."},{"question":"What is the physical size of the LC1E06008M5WBIN?","answer":"Width 45 mm, height 74 mm, depth 80 mm. It mounts on DIN rail or a mounting plate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E06008M5WBIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E06008M5WBIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}