{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E06008V7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E06008V7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E06008V7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E06008V7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E06008V7IN, 4P (2NO+2NC) contactor, AC-1 ≤415V 20A, 400V coil.","salesMarkdown":"The Schneider Electric LC1E06008V7IN is a 4-pole (2NO+2NC) contactor from the Easy TeSys Control range, rated for 20 A in AC-1 utilisation category at up to 415 V. This means it's designed specifically for resistive loads — heaters, lighting banks, or similar non-inductive circuits — not for motor starting. The AC-1 rating is the headline figure here: it tells you the contactor can make and break resistive current at that level without accelerated wear. The 400 V coil is standard for 400 VAC control circuits common across European panel builds. The 20 A AC-1 rating governs the resistive load it can switch. Don't confuse this with an AC-3 motor rating — this contactor isn't sized for inductive motor starts. The 4-pole configuration with 2 normally-open and 2 normally-closed contacts gives flexibility for switching multiple load circuits or interlocking control circuits. The 1.5 ms non-overlap time between NC and NO contacts on both energisation and de-energisation is a safety feature: it guarantees that the NC contacts open before the NO contacts close (and vice versa), preventing momentary short-circuits in interlocking applications. Operating altitude is rated to 3000 m, so it's fine for most installations except high-altitude sites above that. The 850 °C fire resistance rating per IEC 60695-2-1 means the contactor housing won't propagate a flame under fault conditions, which is a requirement for most industrial control panels.","metaTitle":"Schneider LC1E06008V7IN Easy TeSys Contactor, 4P, 20A AC-1","metaDescription":"Obsolete Schneider LC1E06008V7IN Easy TeSys Control contactor, 4P (2NO+2NC), 20A AC-1 at 415V. Sourced to order against RFQ. Standards: EN/IEC 60947.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/929979122726b88d20f4310645a000e6.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E06008V7IN/contactoreasy-tesys-controllc1e4p2no+2ncac1415v20a400v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E06008V7IN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a 4-pole (2NO+2NC) contactor rated 20 A in AC-1 utilisation category at up to 415 V, with a 400 V coil. It is designed for resistive loads only, not motor starting."},{"question":"What standards does this contactor comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048.1, GB/T 14048.4, and GB/T 14048.5 standards. It also has 850 °C fire resistance per IEC 60695-2-1."},{"question":"How do I source this obsolete part?","answer":"Since it is obsolete, sourcing is through surplus or broker channels. We can source it to order against an RFQ; availability and lead time depend on current inventory at the time of request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E06008V7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E06008V7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}