{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E0601B7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E0601B7","canonicalUrl":"https://aoctrl.com/schneider/LC1E0601B7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E0601B7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys control, LC1E0601B7, 3-pole contactor, AC-3 6 A at ≤440 V, 24 V AC coil, DIN-rail mount, 45 mm wide.","salesMarkdown":"The 24 V AC coil keeps the control circuit low-voltage, common in PLC-driven panels. The AC-3 utilisation category at 6 A is the headline rating: it confirms the contactor can break motor locked-rotor current (typically 6–8× FLA) and make the inrush without welding contacts. If your motor full-load amps are under 6 A, this part fits. The AC-3e rating (same current) adds a low-energy switching variant for electronic motor starters. The AC-1 resistive rating covers heater banks or lighting loads up to the same 6 A. The 24 V AC coil draws a modest inrush; the non-overlap time of 1.5 ms on both energisation and de-energisation ensures that NC and NO contacts never close simultaneously — important for reversing starters or interlock circuits where a momentary cross-conduction could short phases. At 45 mm wide and 74 mm tall, it fits a standard 8-module spacing on a DIN rail — leaving room for an overload relay or auxiliary contact block alongside. Depth is 80 mm, so it clears most 100 mm deep enclosures with a bit of wiring space behind. Also carries GB/T equivalents for China-market installations. The IP2X degree of protection means it's finger-safe on the front but expects enclosure protection for the terminals.","metaTitle":"Schneider LC1E0601B7 Easy TeSys Contactor, 3P, AC-3 6A, 24V","metaDescription":"Active-production Easy TeSys contactor, 3P (3 NO), AC-3 rated 6 A at ≤440 V, 24 V AC coil. 45 mm wide, DIN-rail mount. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","title":"LC1E0601B7","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","description":"Easy TeSys contactor 3P(3 NO) - AC-3 - <= 440 V 6A - 24 V AC coil","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c4f433a50d493d7d98919b3bd5ed6034.pdf","sourceUrl":"https://www.se.com/in/en/product/LC1E0601B7/easy-tesys-contactor-3p3-no-ac3-440-v-6a-24-v-ac-coil/"},"ai":{"faq":[{"question":"What are the key ratings for the LC1E0601B7?","answer":"It is a 3-pole contactor rated AC-3 at 6 A up to 440 V with a 24 V AC coil. It also carries AC-1 resistive and AC-3e ratings at the same current. Mounts on DIN rail, 45 mm wide."},{"question":"What compliance documentation does this part have?","answer":"It is certified to EN/IEC 60947-1, -4-1, -5-1, and the corresponding GB/T standards. Fire resistance is 850 °C per IEC 60695-2-1. The protective treatment is TH (pollution degree 3) per IEC 60068-2-30."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E0601B7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E0601B7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}