{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E0601E5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E0601E5","canonicalUrl":"https://aoctrl.com/schneider/LC1E0601E5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E0601E5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E0601E5, 3P (3NO) contactor, AC-3/AC-3e 6A ≤440V, 48V AC coil 50Hz, 1NC auxiliary, obsolete.","salesMarkdown":"The AC-3 utilisation category rating means it is tested for switching three-phase induction motors — the 6 A rating at ≤440 V governs the maximum motor current it can handle under starting and plugging conditions, not just the steady-state load. For resistive loads (AC-1), the current capability is higher, but the AC-3 figure is the one that decides fit for a motor BOM line. The coil is 48 V AC at 50 Hz — verify your control transformer matches exactly, as a 48 V coil on a 24 V or 110 V circuit will not pull in reliably. The 1NC auxiliary contact is built in; the guaranteed 1.5 ms non-overlap time between NC and NO poles means it breaks before make, which matters for reversing or star-delta circuits where overlapping power legs would cause a phase-to-phase fault. ## Sourcing reality — obsolete, not a dead end The part carries TH protective treatment (pollution degree 3) per IEC 60068-2-30, so any surplus unit should be stored in a controlled environment — check for corrosion on the terminals and coil pins before acceptance, especially if the part has been sitting on a shelf for years. Mounts on DIN rail or a plate. Operating ambient is -5 to 55 °C without derating; storage range is -60 to 80 °C. At altitudes above 3000 m, the air density drops enough to reduce the dielectric withstand and thermal dissipation — derate per the standard or keep the part below that threshold. Certified to EN/IEC 60947-4-1 (contactor standard) and EN/IEC 60947-5-1 (control circuit devices), plus the Chinese GB/T equivalents. Also complies with EN/IEC 60335-1 Clause 30.2 for glow-wire / fire resistance, and the 850 °C fire resistance test per IEC 60695-2-1 — relevant if the contactor sits in a household or light-commercial appliance enclosure.","metaTitle":"Schneider Electric LC1E0601E5 Easy TeSys Contactor, 3P, 6A,","metaDescription":"Obsolete Schneider Easy TeSys LC1E0601E5 contactor, 3P (3NO), AC-3/AC-3e 6A at ≤440V, 48V AC 50Hz coil, 1NC auxiliary. Sourced to order. RFQ for cross-reference.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/783137a540882afa7e324f55d8f8627b.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1E0601E5/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v6a48v-ac-coil50hz1nc-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E0601E5/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LC1E0601E5?","answer":"No official successor order code is published in the record for this part. A cross-reference would need to be validated against your specific BOM requirements — the replacement should match the 3P, 6 A AC-3, 48 V AC 50 Hz coil, and 1NC auxiliary. Submit an RFQ with your application details."},{"question":"What are the key ratings of the LC1E0601E5?","answer":"Three-pole contactor, 6 A in AC-3 duty at ≤440 V, 48 V AC 50 Hz coil, one normally-closed auxiliary contact. It also carries AC-1 and AC-3e utilisation categories."},{"question":"What compliance documentation is available for the LC1E0601E5?","answer":"The contactor is certified to EN/IEC 60947-1, -4-1, and -5-1, plus the Chinese GB/T 14048 series. It also meets EN/IEC 60335-1 Clause 30.2 and the 850 °C glow-wire test per IEC 60695-2-1. RoHS and REACH compliance are not explicitly stated in the record but are typical for Schneider Easy TeSys products of this era."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E0601E5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E0601E5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}