{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E0601Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E0601Q6","canonicalUrl":"https://aoctrl.com/schneider/LC1E0601Q6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E0601Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, LC1E0601Q6, 3-pole contactor, AC-3/AC-3e 6A at ≤440V, 380V AC 60Hz coil, 1NC auxiliary contact.","salesMarkdown":"It carries a 6 A rating in AC-3 and AC-3e utilisation categories at operational voltages up to 440 V, with a 380 V AC 60 Hz coil and one normally-closed auxiliary contact. The AC-3 rating of 6 A at ≤440 V is what governs motor switching — this contactor handles a 3-phase induction motor drawing up to 6 A under full-load starting conditions. The AC-3e rating extends that to energy-efficient motors with higher inrush. The 380 V AC 60 Hz coil means this contactor is designed for North American or other 60 Hz supply systems at that voltage. The 1NC auxiliary contact provides a feedback path for status monitoring or interlocking without needing an add-on block. The IP2X finger protection means it's safe for open-panel use but not washdown environments. Operating altitude is 3000 m without derating, and the permissible ambient temperature range is -20 to 70 °C at the coil rated voltage, with storage from -60 to 80 °C. ## Lifecycle Reality and Sourcing Because there is no official successor order code, any substitution requires a parametric cross-check: the replacement must match the 3-pole, 6 A AC-3, 380 V 60 Hz coil, and 1NC auxiliary contact configuration. A standard TeSys D or TeSys Deca contactor with the same coil voltage and aux contact could work, but the mounting footprint and terminal layout should be verified against the panel cutout.","metaTitle":"Schneider LC1E0601Q6 Easy TeSys Contactor, 3P, 6A AC-3, 380V","metaDescription":"Obsolete Schneider LC1E0601Q6 Easy TeSys Control contactor. 3P, 6A AC-3 at 440V, 380V AC 60Hz coil, 1NC aux. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5b90974dd8ff9e109d76ec25a3479430.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1E0601Q6/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v6a380v-ac-coil60hz1nc-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E0601Q6/alternatives.json"},"ai":{"faq":[{"question":"What are the key specifications of the LC1E0601Q6?","answer":"It is a 3-pole contactor rated 6 A in AC-3/AC-3e at ≤440 V, with a 380 V AC 60 Hz coil and one normally-closed auxiliary contact. It mounts on DIN rail or plate, measures 45 x 74 x 80 mm, and complies with EN/IEC 60947 series standards."},{"question":"How do I source the LC1E0601Q6 if it's obsolete?","answer":"Since it is no longer manufactured, sourcing is through surplus or independent distributor channels. Submit an RFQ for a quote on available new-old-stock or verified pulled inventory."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E0601Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E0601Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}