{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E0610B5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E0610B5","canonicalUrl":"https://aoctrl.com/schneider/LC1E0610B5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E0610B5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control series, LC1E0610B5, 3P (3NO) contactor, AC-3/AC-3e rated 6 A at ≤440 V, 24 V AC 50 Hz coil, 1 NO auxiliary contact, DIN-rail mount.","salesMarkdown":"It switches 6 A in AC-3/AC-3e duty at ≤440 V — that's the standard motor-starting category for squirrel-cage motors, so it handles inrush and break without welding. The 24 V AC 50 Hz coil keeps it in the common control-voltage range for panel designs. One normally open auxiliary contact is built in for feedback or interlocking. The utilisation categories tell you what loads it can handle: AC-3 (motor starting) and AC-1 (resistive). For a 6 A motor at 400 V, this contactor is sized for small conveyors, fans, or pumps — not for heavy-duty or high-cycle applications. The AC-3e rating extends the same category with enhanced electrical endurance, which matters if the line cycles frequently. The 24 V AC coil draws from a standard control transformer; verify the 50 Hz frequency matches your supply. Mounts on DIN rail or plate, so it integrates into a standard panel without extra brackets. Also meets EN/IEC 60335-1 Clause 30.2 and -2-40 Annex JJ for appliance safety, which broadens its acceptance into HVAC and white-goods lines.","metaTitle":"Schneider Electric LC1E0610B5 Easy TeSys Contactor, 3P, 6A,","metaDescription":"Active LC1E0610B5 contactor from Schneider Easy TeSys Control series. 3P (3NO), AC-3/AC-3e rated 6A at ≤440V, 24V AC 50Hz coil, 1NO aux. DIN-rail mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"DIN rail Plate","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"3P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068-2-30","Utilisation category":"AC-3 AC-3e AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$11.17","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/063e366b2ce7b5130a0f86aba9d4ed17.pdf","sourceUrl":"https://www.se.com/mk/en/product/LC1E0610B5/contactoreasy-tesys-controllc1e3p3noac3-ac3e440v6a24v-ac-coil50hz1no-auxiliary-contact/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E0610B5/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to the LC1E0610B5 in the Easy TeSys family?","answer":"Within the same Easy TeSys Control series, a higher-rated variant would be the LC1E0910B5 (9 A AC-3). The footprint and coil voltage match, but the current rating steps up. No pin-compatible drop-in exists with a different coil voltage — the B5 suffix locks in 24 V AC 50 Hz."},{"question":"What compliance documentation does Schneider provide for the LC1E0610B5?","answer":"The contactor is certified to EN/IEC 60947-1, -4-1, -5-1, and GB/T 14048 series. It also meets EN/IEC 60335-1 Clause 30.2 and -2-40 Annex JJ. Fire resistance is 850 °C per IEC 60695-2-1. Protective treatment TH (pollution degree 3) per IEC 60068-2-30. RoHS and REACH declarations are typically available from Schneider's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E0610B5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E0610B5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}