{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1E09004F7IN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1E09004F7IN","canonicalUrl":"https://aoctrl.com/schneider/LC1E09004F7IN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1E09004F7IN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, contactor LC1E09004F7IN, 4P (4 NO), AC-1 ≤415 V 40 A, 110 V AC coil, DIN-rail mount.","salesMarkdown":"The Schneider Electric LC1E09004F7IN is a 4-pole (4 NO) contactor from the Easy TeSys Control range, rated for AC-1 utilisation category at 40 A up to 415 V with a 110 V AC coil. AC-1 covers resistive loads — heaters, ovens, lighting banks — where inrush current is minimal and the switching duty is steady-state. That 40 A figure is the thermal current the main poles carry continuously, not a motor-starting rating; for motor loads you would need an AC-3 rated contactor. ## Standards, approvals, and where this fits in a panel Mounts on a plate or DIN rail (45 mm wide, 74 mm tall, 80 mm deep) — standard panel footprint for a 4-pole block. IP2X finger protection on the contactor body means it is safe for open-panel mounting where accidental touch is a concern. ## What the non-overlap timing and environmental limits tell a commissioning engineer Ambient operating range is -5 to 55 °C, with storage from -60 to 80 °C; the -20 to 70 °C range at Uc applies to the coil voltage tolerance.","metaTitle":"Schneider LC1E09004F7IN Easy TeSys Contactor, 4P 40A AC-1, 1","metaDescription":"Active-production Easy TeSys contactor, 4P (4 NO), AC-1 rated 40 A at ≤415 V, 110 V AC coil. DIN-rail mount, EN/IEC 60947 compliant. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Mounting support":"Plate DIN rail","Non-overlap time":"1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact","Range of product":"Easy TeSys Control","Device short name":"LC1E","Poles description":"4P","Operating altitude":"3000 m","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","IP degree of protection":"IP2X conforming to IEC 60529","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-20...70 °C at Uc -60...80 °C storage -5...55 °C operation"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC1E09004F7IN/easy-tesys-contactor-4p4-no-ac1-415-v-40a-110-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1E09004F7IN/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this contactor carry?","answer":"It is certified to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048 series. Fire resistance is tested to 850 °C per IEC 60695-2-1, and the protective treatment meets TH (pollution degree 3) per IEC 60068."},{"question":"What is the physical size and mounting of this contactor?","answer":"It measures 45 mm wide, 74 mm tall, and 80 mm deep. Mounts on a plate or standard DIN rail."},{"question":"What load type is this contactor rated for?","answer":"It is rated for AC-1 utilisation category, which covers resistive loads. The 40 A rating at ≤415 V applies to steady-state resistive switching, not motor starting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1E09004F7IN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1E09004F7IN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}